Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 303

The DOI matches its Crossref record.

Fault Detection and Isolation in Low-Voltage DC-Bus Microgrid System

Park, Jae-Do, Candelaria, Jared·2013·IEEE Transactions on Power Delivery

Abstract

A fault detection and isolation scheme for low-voltage dc-bus microgrid systems is presented in this paper. Unlike traditional ac distribution systems, protection has been challenging for dc systems. The goals of the proposed scheme are to detect the fault in the bus between devices and to isolate the faulted section so that the system keeps operating without disabling the entire system. To achieve these goals, a loop-type dc-bus-based microgrid system, which has a segment controller between connected components, is proposed. The segment controller consists of master and slave controllers that monitor currents and control the segment separation, which include solid-state bidirectional switches and snubber circuits. The proposed system can detect faults on the bus regardless of fault current amplitude or the power supply's feeding capacity. The proposed concepts have been verified by OrCAD/PSpice simulations and experiments on hardware test bed.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tpwrd.2013.2243478

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 303

Metadata

Authors
Park, J.-D., & Candelaria, J.
Venue
IEEE Transactions on Power Delivery
Published
2013-04
Volume
28
Issue
2
Pages
779-787
ISSN
  • 0885-8977 (ISSN-L)
  • 1937-4208
OpenAlex
W2089212322
Cited by
303
References
0
FWCI
27.18
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Fault Detection and Isolation in Low-Voltage DC-Bus Microgrid System. https://app.cochat.ai/papers/10.1109/tpwrd.2013.2243478
The paper
Park, J.-D., & Candelaria, J. (2013). Fault Detection and Isolation in Low-Voltage DC-Bus Microgrid System. IEEE Transactions on Power Delivery. https://doi.org/10.1109/tpwrd.2013.2243478

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.