The DOI matches its Crossref record.
Impact of HVDC Transmission System Topology on Multiterminal DC Network Faults
Abstract
This paper compares how a dc fault affects a multiterminal dc (MTdc) network depending on the HVDC transmission system topology. To this end, a six-step methodology is proposed for the selection of the necessary dc fault protection measures. The network consists of four voltage-source converters converters radially connected. The converters natural fault response to a dc fault for the different topologies is studied using dynamic simulation models. For clearing of the dc faults, four different dc breaker technologies are compared based on their fault interruption time, together with a current direction fault detection method. If necessary, the converters are reinforced with limiting reactors to decrease the peak value and rate of rise of the fault currents providing sufficient time for the breakers to isolate the fault without interrupting the MTdc network operation. The study shows that the symmetric monopolar topology is least affected by dc contingencies. Considering bipolar topologies, the bipolar with metallic return exhibits better fault response compared to the one with ground return. Topologies with ground or metallic return require full semiconductor or hybrid breakers with reactors to successfully isolate a dc fault.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Li, R., Xu, L., & Yao, L. (2017) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2016.2590501 · Cited by 350
A Three-Level Modular DC/DC Converter Applied in High Voltage DC Grid
You, H., & Cai, X. (2018) · IEEE Access · doi:10.1109/access.2018.2829703 · Cited by 34
Metadata
- Authors
- Kontos, E., Pinto, R. T., Rodrigues, S., & Bauer, P.
- Venue
- IEEE Transactions on Power Delivery
- Published
- 2015-04
- Volume
- 30
- Issue
- 2
- Pages
- 844-852
- ISSN
- 0885-8977 (ISSN-L)
- 1937-4208
- OpenAlex
- W2013877857
- Cited by
- 175
- References
- 0
- FWCI
- 9.37
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Impact of HVDC Transmission System Topology on Multiterminal DC Network Faults. https://app.cochat.ai/papers/10.1109/tpwrd.2014.2357056
- The paper
- Kontos, E., Pinto, R. T., Rodrigues, S., & Bauer, P. (2015). Impact of HVDC Transmission System Topology on Multiterminal DC Network Faults. IEEE Transactions on Power Delivery. https://doi.org/10.1109/tpwrd.2014.2357056
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.