Active ROCOF Relay for Islanding Detection
The DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.
Abstract
Intentional frequency perturbation by recently researched active islanding detection techniques for inverter based distributed generation (DG) define new threshold settings for the frequency relays. This innovation has enabled the modern frequency relays to operate inside the non-detection zone (NDZ) of the conventional frequency relays. However, the effect of such perturbation on the performance of the rate of change of frequency (ROCOF) relays has not been researched so far. This paper evaluates the performance of ROCOF relays under such perturbations for an inverter interfaced DG and proposes an algorithm along with the new threshold settings to enable it work under the NDZ. The proposed algorithm is able to differentiate between an islanding and a non-islanding event. The operating principle of relay is based on low frequency current injection through grid side voltage source converter (VSC) control of doubly fed induction generator (DFIG) and therefore, the relay is defined as “active ROCOF relay”. Simulations are done in MATLAB.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Microgrids and Active Distribution Networks
Chowdhury, S., Chowdhury, S., & Crossley, P. A. (2009) · Institution of Engineering and Technology eBooks · doi:10.1049/pbrn006e · Cited by 1,198
Liserre, M., Sauter, T., & Hung, J. (2010) · IEEE Industrial Electronics Magazine · doi:10.1109/mie.2010.935861 · Cited by 1,054
Vector analysis and control of advanced static VAR compensators
Schauder, C., & Mehta, H. (1993) · IEE Proceedings C Generation, Transmission and Distribution · doi:10.1049/ip-c.1993.0044 · Cited by 1,049 · cited 3×
“The frequency measurement at PCC is done with the help of a PLL.”
BackgroundInfluentialGuerrero, J. M., Loh, P. C., Lee, T.-L., & Chandorkar, M. (2013) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2012.2196889 · Cited by 965
Jang, S.-I., & Kim, K.-H. (2004) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2003.822964 · Cited by 592
Evaluation of Islanding Detection Methods for Utility-Interactive Inverters in Photovoltaic Systems
Bower, W., & Ropp, M. E. (2002) · OSTI OAI (U.S. Department of Energy Office of Scientific and Technical Information) · doi:10.2172/806700 · Cited by 574
Comparative Analysis Between ROCOF and Vector Surge Relays for Distributed Generation Applications
Freitas, W., Xu, W., Affonso, C. M., & Huang, Z. (2005) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2004.834869 · Cited by 377
Negative-Sequence Current Injection for Fast Islanding Detection of a Distributed Resource Unit
Karimi, H., Yazdani, A., & Iravani, R. (2008) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2007.911774 · Cited by 377
Ropp, M. E., Begovic, M. M., Rohatgi, A., Kern, G., Bonn, R., & Gonzalez, S. (2000) · IEEE Transactions on Energy Conversion · doi:10.1109/60.875495 · Cited by 346
Yafaoui, A., Wu, B., & Kouro, S. (2012) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2011.2171997 · Cited by 214
Cited by
Support Vector Machine-Based Islanding and Grid Fault Detection in Active Distribution Networks
Baghaee, H. R., Mlakic, D., Nikolovski, S., & Dragicevic, T. (2020) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2019.2916621 · Cited by 235
Metadata
- Authors
- Gupta, P., Bhatia, R. S., & Jain, D. K.
- Venue
- IEEE Transactions on Power Delivery
- Published
- 2017-02
- Volume
- 32
- Issue
- 1
- Pages
- 420-429
- ISSN
- 0885-8977 (ISSN-L)
- 1937-4208
- OpenAlex
- W2474651368
- Cited by
- 188
- References
- 17
- FWCI
- 9.45
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Active ROCOF Relay for Islanding Detection. https://app.cochat.ai/papers/10.1109/tpwrd.2016.2540723
- The paper
- Gupta, P., Bhatia, R. S., & Jain, D. K. (2017). Active ROCOF Relay for Islanding Detection. IEEE Transactions on Power Delivery. https://doi.org/10.1109/tpwrd.2016.2540723
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.