Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 351

The DOI matches its Crossref record.

A Non-unit Protection Scheme for DC Microgrid Based on Local Measurements

Meghwani, A., Srivastava, S. C., Chakrabarti, S.·2017·IEEE Transactions on Power Delivery

Abstract

This paper proposes a nonunit protection scheme for DC microgrids (DC MGs) utilizing only local measurements. This scheme is developed based on the natural characteristics of DC current and its first and second derivatives under fault transients. Since it is based on local measurements, the problems associated with the communication delay are avoided. The selected protection scheme detects and discriminates the faults within a few microseconds of its inception. In this paper, a method to calculate the thresholds, used for the protection scheme, is also discussed. The proposed scheme is validated on a ring-type DC MG architecture under different fault scenarios and tested through MATLAB/Simulink simulations.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tpwrd.2016.2555844

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 351

Metadata

Authors
Meghwani, A., Srivastava, S. C., & Chakrabarti, S.
Venue
IEEE Transactions on Power Delivery
Published
2017-02
Volume
32
Issue
1
Pages
172-181
ISSN
  • 0885-8977 (ISSN-L)
  • 1937-4208
OpenAlex
W2339766197
Cited by
351
References
0
FWCI
22.45
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A Non-unit Protection Scheme for DC Microgrid Based on Local Measurements. https://app.cochat.ai/papers/10.1109/tpwrd.2016.2555844
The paper
Meghwani, A., Srivastava, S. C., & Chakrabarti, S. (2017). A Non-unit Protection Scheme for DC Microgrid Based on Local Measurements. IEEE Transactions on Power Delivery. https://doi.org/10.1109/tpwrd.2016.2555844

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.