Modular Multilevel Converter DC Fault Protection
Open accessThe DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.
Abstract
High-voltage direct current (HVDC) grids will require the development of dc protections that provide fast fault isolation and minimize the disturbance caused to the existing ac power networks. This paper investigates how the dc fault recovery performance of a half-bridge modular multilevel converter (HB-MMC) is impacted by different dc protection design choices. An HB-MMC point-to-point HVDC system that is protected with dc circuit breakers (CBs) is simulated on a real-time digital simulator using detailed switch models of the converters and switch gear. A dc CB controller has been developed and implemented in a software-in-the-loop fashion, and has been made available free for download. A novel blocking scheme for the HB-MMC is proposed, which limits the prospective dc-side fault current, benefiting dc switch gear. A comparison of circulating current controllers shows that the standard d -q controller is likely to be unsuitable for fault studies. Finally, benchmarking shows that a 48% reduction in power-flow recovery time and a 90% reduction in the energy dissipated in the circuit breaker can be achieved, along with other benefits, depending on the protection design.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Pou, J., Ceballos, S., Konstantinou, G., Agelidis, V. G., Picas, R., & Zaragoza, J. (2015) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2014.2336608 · Cited by 406
Self-citationThe Alternate Arm Converter: A New Hybrid Multilevel Converter With DC-Fault Blocking Capability
Merlin, M. M. C., Green, T. C., Mitcheson, P. D., Trainer, D. R., Critchley, R., Crookes, W., & Hassan, F. (2014) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2013.2282171 · Cited by 402
HVDC Grids: For Offshore and Supergrid of the Future
(2016) · Wiley eBooks · doi:10.1002/9781119115243 · Cited by 266
Continuous Operation of Radial Multiterminal HVDC Systems Under DC Fault
Li, R., Xu, L., Holliday, D., Page, F., Finney, S. J., & Williams, B. W. (2015) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2015.2471089 · Cited by 171
Impact of DC Breaker Systems on Multiterminal VSC-HVDC Stability
Wang, W., Barnes, M., Marjanovic, O., & Cwikowski, O. (2016) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2015.2409132 · Cited by 168
Self-citationCirculating current suppressing controller in modular multilevel converter
Tu, Q., Xu, Z., & Zhang, J. (2010) · IECON 2010 - 36th Annual Conference on IEEE Industrial Electronics Society · doi:10.1109/iecon.2010.5675048 · Cited by 137 · cited 15×
“During the transient, CCSC can only track and suppress the second harmonic component of the circulating current while FCCC actively sets a reference to the circulating current.”
MethodInfluentialDevelopment and test of a 200kV full-bridge based hybrid HVDC breaker
Zhou, W., Wei, X., Zhang, S., Tang, G., He, Z., Zheng, J., Dan, Y., & Gao, C. (2015) · European Conference on Power Electronics and Applications · doi:10.1109/epe.2015.7309153 · Cited by 134 · cited 2×
“LCSs, or similar, appear in at least three industrial prototypes [3], [4], [11].”
BackgroundAn enhanced MMC topology with DC fault ride-through capability
Li, X., Liu, W., Song, Q., Rao, H., & Xu, S. (2013) · IECON 2013 - 39th Annual Conference of the IEEE Industrial Electronics Society · doi:10.1109/iecon.2013.6700152 · Cited by 92 · cited 1×
“This modified blocking scheme can be used to prevent pseudo-rectifier operation, just as the double bypass thyristors can [17], [16].”
MethodOperating DC Circuit Breakers With MMC
Cwikowski, O., Wood, A. R., Miller, A., Barnes, M., & Shuttleworth, R. (2017) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2017.2658540 · Cited by 92 · cited 2×
“This modified blocking scheme can be used to prevent pseudo-rectifier operation, just as the double bypass thyristors can [17], [16].”
BackgroundMethodSelf-citationModelling of high‐power hybrid DC circuit breaker for grid‐level studies
Lin, W., Jovcic, D., Nguefeu, S., & Saad, H. (2016) · IET Power Electronics · doi:10.1049/iet-pel.2015.0518 · Cited by 86
Research works printed but not linked: 2
- cwikowski, 2015, Analysis and simualtion of the proactive hybrid circuit breaker, Proc 11th IEEE Int Conf Power Electron Drive Syst, 4
- dupraz, 2014, Development of a 120 kV direct current circuit breaker, CIGRE
Cited by
Items 101–119 of 119
Fault Handling Method in an HVDC System with Half-Bridge MMCs and Hybrid DC Circuit Breakers
Enomoto, M., Sano, K., Koyama, Y., Sekiguchi, K., Ishiguro, T., & Suzuki, D. (2023) · IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce53617.2023.10362068 · Cited by 1
Ukil, A., Yeap, Y. M., & Satpathi, K. (2020) · Power systems · doi:10.1007/978-981-15-2977-1_10
Intelligent Fault Localization for Meshed HVDC Transmission Systems
Inwumoh, J., Baguley, C., & Gunawardane, K. (2020) · Australasian Universities Power Engineering Conference
Protection Strategy Impact on the Interaction Between Converters
Zaidi, S. N. F. (2020) · ERA: Education and Research Archive (University of Alberta) · doi:10.7939/r3-jpvv-w220
Auxiliary DC Fault Clearing Strategy for Low Capacitance Half-bridge MMC
Yang, Y., Fan, Q., Xu, J., Zhao, C., Xue, Y., & Zhu, Q. (2022) · International Conference on Power and Energy Technology (ICPET) · doi:10.1109/icpet55165.2022.9918285
“The expression for the fault current under DC fault of MMC is shown in (6) [18]:”
BackgroundA Novel DC Line Pilot Protection Scheme Based on Additional Current-Limiting Control of HB-MMC
Qin, X., Fan, Y., Hou, J., Li, Y., & Cao, R. (2023) · IEEE International Conference on Advanced Power System Automation and Protection (APAP) · doi:10.1109/apap59666.2023.10348409
“At the device level, there are methods such as improving the MMC sub-module topology and installing DC current limiters[6].”
MethodWang, X. (2023) · Asia-Pacific Conference on Image Processing, Electronics and Computers (IPEC) · doi:10.1109/ipec57296.2023.00048
“Thus, study of protection schemes for flexible DC system contributes a lot in maintaining the safe operation of new power systems [5-6].”
BackgroundThe flexible current limiting device's optimization method and improved control technique
Zheng, F., Wang, W., Zhong, H., Liang, N., & Lın, Y. (2024) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2024.109972
EMT Simulation Based Parametric Tuning of Damping Support in MMC- HVDC Networks
Sharma, M., Pálenský, P., & Rueda, J. L. (2024) · IEEE International Symposium on Industrial Electronics (ISIE) · doi:10.1109/isie54533.2024.10595691
“…scrutinized the recovery process of a single converter, the comprehensive understanding of fault recovery in interconnected HVDC networks and the intricate interplay between converters and the HVDC network during system recovery remains a largely unexplored area in existing literature [4] [5] [6].”
BackgroundVariable Speed Drive Applications Performing Effectively with ANN Technique
Kumar, A. S., Saravanan, R., Vasanthi, S., & Raja, R. A. A. (2024) · Wireless Personal Communications · doi:10.1007/s11277-024-11538-w
“Existing pulse width modulation techniques [7-10] like flying capacitor type, H-bridge type neutral point clamped, space vector modulation, fuzzy logic techniques etc. are employing elsewhere in the world.”
BackgroundLi, X., Li, Q., Li, H., Zhou, X., & Dai, Z. (2025) · Electronics · doi:10.3390/electronics14061120
Guo, C., Du, T., Wang, Y., & Liao, J. (2024) · Asia-Pacific Power and Energy Engineering Conference (APPEEC) · doi:10.1109/appeec61255.2024.10922293
“There are several improvements including paralleling thyristors at both ends of the submodule to facilitate bypassing after a fault [2], using enhanced self-blocking submodules [3], employing diode-clamped submodules [4], and utilizing full-bridge submodules [5].”
Wang, Y. (2025) · Power System and Green Energy Conference (PSGEC) · doi:10.1109/psgec66102.2025.11151063
“When the sub module is locked, all switches are closed[6-7].”
Innovative Design of a Batch Detection Device for Flexible DC Converter Valve Sub-Module
Zhang, G., Lifeng, Z. U., Liu, Z., Teng, L., Liu, L., & Mu, X. (2025) · IEEE International Conference on Power, Intelligent Computing and Systems (ICPICS) · doi:10.1109/icpics66386.2025.11347177
“…on-site test method, the low-pressure pressurization testing can comprehensively test the communication between the sub-module and the valve control, the status of the power circuit and the functions of the secondary equipment without changing the hardware structure of the sub-module [5,6].”
Saleem, M. H., Amin, A. A., Alqarni, Z. A., & Shahzad, U. (2026) · Engineering Reports · doi:10.1002/eng2.70824 · Cited by 2
“In this way, we can approximate the capacitor voltage in the SM of MMC [ 32, 33].”
DIRECTIONS D3.3: Report on DC Protection for Electrical Energy Hubs
Deyck, M. V., Mohammadi, A., Chaffey, G. P., & Hertem, D. V. (2026) · Lirias (KU Leuven) · doi:10.5281/zenodo.20841216
Coordinated Fault Ride-Through Control Strategy for DC Grids Based on Hybrid MMC
He, J. (2026) · IEEE International Conference on Information Technology, Big Data and Artificial Intelligence (ICIBA) · doi:10.1109/iciba68339.2026.11651824
Zhou, Z., Tao, J., & Deng, T. (2026) · International Conference on Energy, Power and Electrical Technology (ICEPET) · doi:10.1109/icepet70032.2026.11725704
“Currently, fault current limiting methods on the DC side are mainly divided into control-based limiting and device-based limiting [2].”
Metadata
- Authors
- Cwikowski, O., Wickramasinghe, H. R., Konstantinou, G., Pou, J., Barnes, M., & Shuttleworth, R.
- Affiliations
- University of Manchester (GB)
- UNSW Sydney (AU)
- Nanyang Technological University (SG)
- Venue
- IEEE Transactions on Power Delivery
- Published
- 2018-02
- Volume
- 33
- Issue
- 1
- Pages
- 291-300
- ISSN
- 0885-8977 (ISSN-L)
- 1937-4208
- OpenAlex
- W2626022691
- Cited by
- 118
- References
- 17
- Citations by year
- 2026: 3 · 2025: 6 · 2024: 7 · 2023: 8 · 2022: 14 · 2021: 11 · 2020: 18 · 2019: 21 · 2018: 17
- FWCI
- 7.05
- Type
- journal article
- Language
- en
- Open access
- Licence
- Locations
- IEEE Transactions on Power Delivery (publishedVersion)
- Research Explorer (The University of Manchester) (publishedVersion, other-oa)
- UNSWorks (University of New South Wales, Sydney, Australia) (submittedVersion, cc-by-nc-nd)
- UNSWorks (UNSW Sydney) (submittedVersion, cc-by-nc-nd)
- DR-NTU (Nanyang Technological University) (submittedVersion)
- Funders
- Engineering and Physical Sciences Research Council
- National Grid (EP/L021552/1, TAO/22360)
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › HVDC Systems and Fault Protection
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Multilevel Inverters and Converters
- Physical Sciences › Engineering › Control and Systems Engineering › Power Systems Fault Detection
- Keywords
- modular multilevel converter, HVDC grids, DC fault protection, DC circuit breakers, fault recovery, blocking schemes, circulating current control, dq control, point-to-point HVDC, real-time digital simulation, software-in-the-loop simulation
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.