Decoupled Current Control With Synchronous Frequency Damping for MMC Considering Sub-module Capacitor Voltage Ripple
The DOI matches its Crossref record; 30 of the 31 references it cites were found in a registry or an index.
Abstract
Capacitor voltage ripple in the fundamental frequency is distinctive in the performance of modular multilevel converters (MMCs), unlike other voltage-source converters. First, in order to reveal the influence of capacitor voltage ripple, the coupling effect of conventional MMC double-loop control strategy is investigated to explain the unsatisfactory response. Then, decoupled current control with synchronous frequency damping is proposed, eliminating the coupling terms in the presented average value MMC model, which can improve the system dynamic behavior. Moreover, the damping index is defined and designed in the proposed control strategy to compromise between current decoupling and oscillation damping. Furthermore, the dynamic MMC characteristics with the decoupled current control and appropriate damping index are explored with detailed theoretical analysis. Finally, the simulation results validate the effectiveness of the proposed control strategy.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
VSC-Based HVDC Power Transmission Systems: An Overview
Flourentzou, N., Agelidis, V. G., & Demetriades, G. D. (2009) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2008.2008441 · Cited by 2,216 · cited 1×
“Since the independent reactive power control, black-start capability, and smaller station footprint can be accomplished, the voltage source converter based HVDC (VSC-HVDC) systems are recognized as superior to the line-commutated converter based HVDC (LCC-HVDC) [4]–[6].”
BackgroundThe age of multilevel converters arrives
Franquelo, L., Rodriguez, J., Leon, J., Kouro, S., Portillo, R., & Prats, M. (2008) · IEEE Industrial Electronics Magazine · doi:10.1109/mie.2008.923519 · Cited by 2,016 · cited 1×
“For the MMC, VSC control is usually similar to other VSCs [15], [16].”
BackgroundTu, Q., Xu, Z., & Xu, L. (2011) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2011.2115258 · Cited by 1,387
On dynamics and voltage control of the Modular Multilevel Converter
Antonopoulos, A., Ängquist, L., & Nee, H. (2009) · European Conference on Power Electronics and Applications · Cited by 831
A New AC/AC Multilevel Converter Family
Glinka, M., & Marquardt, R. (2005) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2005.843973 · Cited by 772 · cited 1×
“Among various VSC topologies, the modular multilevel converters (MMCs) have many attractive properties [7], [8].”
BackgroundThe ABCs of HVDC transmission technologies
Bahrman, M., & Johnson, B. (2007) · IEEE Power and Energy Magazine · doi:10.1109/mpae.2007.329194 · Cited by 732 · cited 1×
“H IGH voltage direct current (HVDC) transmission is widely considered to be beneficial for long-distance power delivery, asynchronous interconnections, and long submarine cable crossings [1]–[3].”
BackgroundGuan, M., & Xu, Z. (2012) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2012.2192752 · Cited by 549
Predictive Control of a Modular Multilevel Converter for a Back-to-Back HVDC System
Qin, J., & Saeedifard, M. (2012) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2012.2191577 · Cited by 428
Dynamic Averaged and Simplified Models for MMC-Based HVDC Transmission Systems
Saad, H., Peralta, J., Dennetiere, S., Mahseredjian, J., Jatskevich, J., Martinez, J. A., Davoudi, A., Saeedifard, M., Sood, V., Wang, X., et al. (2013) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2013.2251912 · Cited by 374
Son, G. T., Lee, H.-J., Nam, T. S., Chung, Y.-H., Lee, U.-H., Baek, S.-T., Hur, K., & Park, J.-W. (2012) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2012.2190530 · Cited by 290 · cited 1×
“Thus, the MMC is an emerging and promising converter topology for medium- and high-voltage and high-power applications [10], [11].”
BackgroundModern HVDC PLUS application of VSC in Modular Multilevel Converter topology
Friedrich, K. (2010) · 2010 IEEE International Symposium on Industrial Electronics · doi:10.1109/isie.2010.5637505 · Cited by 280 · cited 1×
“The MMC modularity makes it flexible to extend the rated power and voltage [9].”
BackgroundIndirect Finite Control Set Model Predictive Control of Modular Multilevel Converters
Vatani, M., Bahrani, B., Saeedifard, M., & Hovd, M. (2015) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2014.2377112 · Cited by 253 · cited 1×
“strategies are implemented in MMC including the nonlinearity dynamics [25], [26].”
MethodCirculating Current Control in MMC Under the Unbalanced Voltage
Moon, J.-W., Kim, C.-S., Park, J.-W., Kang, D.-W., & Kim, J.-M. (2013) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2013.2264496 · Cited by 237 · cited 1×
“Furthermore, in order to restrain the circulating currents and reduce the device current stress, proportional-integral (PI) control or proportional-resonant (PR) control are applied in CCSC [21], [22].”
MethodHigh‐Voltage Direct‐Current Transmission: Converters, Systems and DC Grids
Jovcic, D., & Ahmed, K. (2015) · Wiley eBooks · doi:10.1002/9781118846704 · Cited by 231 · cited 2×
“The equivalent AC capacitor is obtained by deriving the phasor domain model of MMC using d-q (active and reactive) components of all variables in [29], [30].”
BackgroundMethodTopologies for VSC transmission
Andersen, B. R., Xu, L., Cartwright, P., & Horton, P. J. (2002) · Power Engineering Journal · doi:10.1049/pe:20020307 · Cited by 195 · cited 1×
“Since the independent reactive power control, black-start capability, and smaller station footprint can be accomplished, the voltage source converter based HVDC (VSC-HVDC) systems are recognized as superior to the line-commutated converter based HVDC (LCC-HVDC) [4]–[6].”
BackgroundGong, Z., Dai, P., Yuan, X., Wu, X., & Guo, G. (2016) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2015.2497254 · Cited by 185 · cited 1×
“strategies are implemented in MMC including the nonlinearity dynamics [25], [26].”
MethodVasiladiotis, M., Cherix, N., & Rufer, A. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2286293 · Cited by 174 · cited 3×
“In order to build a more accurate model of MMC to describe the performance of output voltages and currents, an average value model (AVM) considering sub-module capacitor voltage ripple is proposed in [27], and is plotted in Fig.”
BackgroundMethodInfluentialMMC Capacitor Voltage Decoupling and Balancing Controls
Saad, H., Guillaud, X., Mahseredjian, J., Dennetiere, S., & Nguefeu, S. (2015) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2014.2338861 · Cited by 162
A new AC/AC-multilevel converter family applied to a single-phase converter
Glinka, M., & Marquardt, R. (2004) · The Fifth International Conference on Power Electronics and Drive Systems, 2003. PEDS 2003. · doi:10.1109/peds.2003.1282669 · Cited by 150 · cited 1×
“Among various VSC topologies, the modular multilevel converters (MMCs) have many attractive properties [7], [8].”
BackgroundDarus, R., Pou, J., Konstantinou, G., Ceballos, S., Picas, R., & Agelidis, V. G. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2014.2359005 · Cited by 131
Power Distribution in Hybrid Multi-cell Converter with Nearest Level Modulation
Perez, M., Rodriguez, J., Pontt, J., & Kouro, S. (2007) · 2007 IEEE International Symposium on Industrial Electronics · doi:10.1109/isie.2007.4374688 · Cited by 131 · cited 1×
“Since MMC has hundreds of levels in HVDC systems, NLM is widely used for easy implementation [17].”
BackgroundPhasor Model of Modular Multilevel Converter With Circulating Current Suppression Control
Jovcic, D., & Jamshidi Far, A. (2015) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2014.2372780 · Cited by 106 · cited 1×
“The equivalent AC capacitor is obtained by deriving the phasor domain model of MMC using d-q (active and reactive) components of all variables in [29], [30].”
MethodA Coherency-Based Equivalence Method for MMC Inverters Using Virtual Synchronous Generator Control
Li, C., Xu, J., & Zhao, C. (2015) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2015.2499262 · Cited by 106 · cited 1×
“In large-scale renewable energy systems, the MMC coherency equivalence method is used to connect the AC grid with virtual synchronous generator (VSG) control [24].”
MethodAverage-Value Model of Modular Multilevel Converters Considering Capacitor Voltage Ripple
Yang, H., Dong, Y., Li, W., & He, X. (2016) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2016.2555983 · Cited by 105 · cited 1×
“Actually, there is an equivalent AC capacitor in the MMC model [28], where the equivalent AC capacitor reflects the sub-module voltage ripple capacitor onto the MMC ac side.”
BackgroundSelf-citationLong-term coordination of transmission and storage to integrate wind power
Conejo, A. J., Cheng, Y., Zhang, N., & Kang, C. (2017) · CSEE Journal of Power and Energy Systems · doi:10.17775/cseejpes.2017.0006 · Cited by 82 · cited 1×
“H IGH voltage direct current (HVDC) transmission is widely considered to be beneficial for long-distance power delivery, asynchronous interconnections, and long submarine cable crossings [1]–[3].”
BackgroundTopologies for VSC transmission
Andersen, B. R. (2001) · IET International Conference on AC and DC Power Transmission (ACDC) · doi:10.1049/cp:20010559 · Cited by 75
Abdelsalam, M. O., Marei, M. I., Tennakoon, S. B., & Griffiths, A. L. (2016) · CSEE Journal of Power and Energy Systems · doi:10.17775/cseejpes.2016.00010 · Cited by 59 · cited 1×
“On account of the floating sub-module capacitors, BCA is employed to control the capacitor voltages around reference value in each arm [18]–[20].”
MethodDroop control method for load share and voltage regulation in high-voltage microgrids
Shuai, Z., Mo, S., Wang, J., Shen, Z. J., Wei, T. I. A. N., & Feng, Y. (2016) · Journal of Modern Power Systems and Clean Energy · doi:10.1007/s40565-015-0176-1 · Cited by 57
MMC Stored Energy Participation to the DC Bus Voltage Control in an HVDC Link
Samimi, S., Gruson, F., Delarue, P., Colas, F., Belhaouane, M. M., & Guillaud, X. (2016) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2016.2540926 · Cited by 50 · cited 1×
“Since the dc capacitor does not directly connect to the DC bus in the MMC, energy-based control is applied to improve the dynamic behavior of HVDC link [23].”
BackgroundInter-harmonics in multi-terminal VSC-based HVDC systems
Han, M., Nguyen, P., & Yan, W. (2015) · Journal of Modern Power Systems and Clean Energy · doi:10.1007/s40565-015-0173-4 · Cited by 17
Research works printed but not linked: 2
- lesnicar, 2008, Neuartiger Modularer Mehrpunktumrichter M2C für Netzkupplungsanwendungen
- 10.1109/tpel.2013.2286293 · DOI · Paper page
Cited by
Modular Multilevel Converters: Recent Achievements and Challenges
Perez, M. A., Ceballos, S., Konstantinou, G., Pou, J., & Aguilera, R. P. (2021) · IEEE Open Journal of the Industrial Electronics Society · doi:10.1109/ojies.2021.3060791 · Cited by 327
“improving the dynamic performance [62].”
Power coupling analysis and improved decoupling control for the VSC connected to a weak AC grid
Shao, B., Xiao, Q., Xiong, L., Wang, L., Yang, Y., Chen, Z., Blaabjerg, F., & Guerrero, J. M. (2022) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2022.108645 · Cited by 101
Jia, G., Chen, M., Tang, S. Y., Zhang, C., & Zhu, G. (2020) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2020.3016493 · Cited by 59
“3016493 H-bridge (CHB) converter [1]–[4].”
BackgroundPower Decoupling Control for Modular Multilevel Converter
Wang, J., & Wang, P. (2018) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2018.2799321 · Cited by 53
“In [49], capacitor voltage ripple inside”
Jia, G., Chen, M., Tang, S. Y., Zhang, C., & Zhao, B. (2020) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2020.2982440 · Cited by 51
“(19) In the traditional MMC topology, the capacitance values of SMs are designed to be quite large to restrain the ripple powers [10], and the design formula of SM capacitor voltage volatility ε is as follows [33]:”
Background
Metadata
- Authors
- Yang, H., Li, W., Lin, L., & He, X.
- Affiliations
- Zhejiang University (CN)
- State Key Laboratory of Advanced Electromagnetic Engineering and Technology (CN)
- Venue
- IEEE Transactions on Power Delivery
- Published
- 2018-02
- Volume
- 33
- Issue
- 1
- Pages
- 419-428
- ISSN
- 0885-8977 (ISSN-L)
- 1937-4208
- OpenAlex
- W2732311714
- Cited by
- 33
- References
- 31
- Citations by year
- 2026: 2 · 2025: 4 · 2024: 3 · 2023: 1 · 2022: 3 · 2021: 6 · 2020: 8 · 2018: 6
- FWCI
- 1.59
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- IEEE Transactions on Power Delivery (publishedVersion)
- Funders
- National Basic Research Program of China (2014CB247400)
- Zhejiang Provincial Natural Science Foundation (LR16E070001)
- HUST State Key Laboratory of Advanced Electromagnetic Engineering and Technology (2017KF002)
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › HVDC Systems and Fault Protection
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Multilevel Inverters and Converters
- Physical Sciences › Engineering › Control and Systems Engineering › Microgrid Control and Optimization
- Keywords
- modular multilevel converter, decoupled current control, damping index, converter dynamic behavior, vibration damping
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.