The DOI matches its Crossref record.
Reinforcing Fault Ride Through Capability of Grid Forming Voltage Source Converters Using an Enhanced Voltage Control Scheme
Open accessAbstract
Medium power distributed energy resources (DERs) are commonly connected to medium voltage distribution systems via voltage source converters (VSCs). Several guidelines and standards have been developed to establish the needed criteria and requirements for DERs interconnections. In this respect, it is preferred to reinforce the VSC fault ride through (FRT) capability, which considerably minimizes the DG outage period and reconnection time and results in a resilient system against short circuits. Considering the significant number of asymmetrical faults in distribution systems, the VSC response in such conditions must be investigated, and consequently, its FRT capability must be reinforced. In this paper, first, a comprehensive review on the existing FRT methods has been presented and discussed. Accordingly, an adaptive virtual impedance-based voltage reference generation method is proposed, which enhances the VSC behavior under short circuits and increases the VSC FRT capability. Also, a fast sinusoidal current reference limiter is proposed to improve the performance. To evaluate the performance of the proposed scheme, state-space analysis is presented, and a complete set of simulations is performed in PSCAD/EMTDC environment. Also, a comparison with the conventional method is presented.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Grid-Forming Converters: Control Approaches, Grid-Synchronization, and Future Trends—A Review
Rosso, R., Wang, X., Liserre, M., Lu, X., & Engelken, S. (2021) · IEEE Open Journal of Industry Applications · doi:10.1109/ojia.2021.3074028 · Cited by 1,187
Grid Forming Inverter Modeling, Control, and Applications
Rathnayake, D. B., Akrami, M., Phurailatpam, C., Me, S. P., Hadavi, S., Jayasinghe, G., Zabihi, S., & Bahrani, B. (2021) · IEEE Access · doi:10.1109/access.2021.3104617 · Cited by 630
Zhang, H., Xiang, W., Lin, W., & Wen, J. (2021) · Journal of Modern Power Systems and Clean Energy · doi:10.35833/mpce.2021.000257 · Cited by 529
Current Limiting Control With Enhanced Dynamics of Grid-Forming Converters During Fault Conditions
Taul, M. G., Wang, X., Davari, P., & Blaabjerg, F. (2020) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2019.2931477 · Cited by 466
Self-citationA Review of Current-Limiting Control of Grid-Forming Inverters Under Symmetrical Disturbances
Fan, B., Liu, T., Zhao, F., Wu, H., & Wang, X. (2022) · IEEE Open Journal of Power Electronics · doi:10.1109/ojpel.2022.3227507 · Cited by 371
“It can be seen that the inverter terminal voltage can well within 1 p . during the low-voltage ride-though process. the results with a decreased X/R ratio to 0.2 given .”
BackgroundInfluential
Metadata
- Authors
- Zarei, S. F., Mokhtari, H., Ghasemi, M. A., & Blaabjerg, F.
- Venue
- IEEE Transactions on Power Delivery
- Published
- 2019-10
- Volume
- 34
- Issue
- 5
- Pages
- 1827-1842
- ISSN
- 0885-8977 (ISSN-L)
- 1937-4208
- OpenAlex
- W2806063773
- Cited by
- 177
- References
- 0
- FWCI
- 7.91
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Reinforcing Fault Ride Through Capability of Grid Forming Voltage Source Converters Using an Enhanced Voltage Control Scheme. https://app.cochat.ai/papers/10.1109/tpwrd.2018.2844082
- The paper
- Zarei, S. F., Mokhtari, H., Ghasemi, M. A., & Blaabjerg, F. (2019). Reinforcing Fault Ride Through Capability of Grid Forming Voltage Source Converters Using an Enhanced Voltage Control Scheme. IEEE Transactions on Power Delivery. https://doi.org/10.1109/tpwrd.2018.2844082
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.