Effect of Voltage Waveforms of HVDC Converter Transformer on Lifetime Characteristics
The DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.
Abstract
The converter transformers are reported to fail generally on the thyristor-valve side, where complex alternating voltage waveforms superimposed with dc voltages would occur. The effect of these waveforms on the failure and endurance of the valve side winding insulation of the transformers is not yet understood, which is investigated here. In this paper, the voltage waveforms occurring in a converter transformer are obtained through PSCAD/EMTDC for a typical double pole ±500 kV, 1000 MW DC-link HVDC transmission system based on the CIGRE benchmark system. The waveforms are then amplified using a High Voltage amplifier for experimental breakdown investigations. Stepped-stress damage equalization method has been used for obtaining the lifetime characteristics from failure data. A comparison with life curve under pure sinusoidal and actual alternating voltages with superimposed dc and harmonic voltage has been made to understand why the converter transformers generally failed on the valve side. The results first time give fundamental reasons for the possible failure of the converter transformers and put forth important design considerations.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Research works in [1] and [2] designed MF frequency transformers for inductor tank based MV dc SST with PWM frequencyfrom3to20kHz.Theinsulationmaterialofthewindings is presented but the insulation performance remains untested.”
In the citing paper
“However, the PD effects on transformer lifetime have not been studied in [11].”
Citations
Cites
Optimal acquisition and aggregation of offshore wind power by multiterminal voltage-source HVDC
Lu, W., & Ooi, B.-T. (2003) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2002.803826 · Cited by 333
Effect of supply voltage frequency on testing of insulation system
Cavallini, A., & Montanari, G. C. (2006) · IEEE Transactions on Dielectrics and Electrical Insulation · doi:10.1109/tdei.2006.1593409 · Cited by 144
(1951) · Journal of the Franklin Institute · doi:10.1016/0016-0032(51)90023-3 · Cited by 136
Dielectric heating in insulating materials subjected to voltage waveforms with high harmonic content
Sonerud, B., Bengtsson, T., Blennow, J., & Gubanski, S. M. (2009) · IEEE Transactions on Dielectrics and Electrical Insulation · doi:10.1109/tdei.2009.5211835 · Cited by 107
Analysis of Converter Transformer Failure in HVDC Systems and Possible Solutions
Bhuvaneswari, G., & Mahanta, B. C. (2009) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2009.2014271 · Cited by 93
Progressive Stress-A New Accelerated Approach to Voltage Endurance
Starr, W. T., & Endicolt, H. S. (1961) · Transactions of the American Institute of Electrical Engineers Part III Power Apparatus and Systems · doi:10.1109/aieepas.1961.4501081 · Cited by 93
Luo, L., Li, Y., Xu, J., Li, J., Hu, B., & Liu, F. (2008) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2008.919160 · Cited by 81
WOLNY, S., Adamowicz, A., & Lepich, M. (2014) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2013.2270917 · Cited by 73
Physics-Based High-Frequency Transformer Modeling by Finite Elements
Abed, N. Y., & Mohammed, O. A. (2010) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2010.2048017 · Cited by 71
The electrical breakdown characteristics of oil-paper insulation under steep front impulse voltages
Vandermaar, A. J., Wang, M., Neilson, J. B., & Srivastava, K. D. (1994) · IEEE Transactions on Power Delivery · doi:10.1109/61.329525 · Cited by 58
Research works printed but not linked: 2
- bastos, 2006, HVDC converter transformer performance on ITAIPU system, CIGRE Paris Symp
- 2007, IEEE Guide for the Statistical Analysis of Electrical Insulation Breakdown Data
Cited by
Agarwal, R., Li, H., Guo, Z., & Cheetham, P. (2023) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2022.3174243 · Cited by 79
Lu, G., Zheng, D., Zhang, Q., & Zhang, P. (2021) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2021.3118020 · Cited by 25
Hybrid Algorithm for Dynamic Fault Prediction of HVDC Converter Transformer Using DGA Data
Patil, M., Paramane, A., Das, S. K., Rao, U. M., & Rózga, P. (2024) · IEEE Transactions on Dielectrics and Electrical Insulation · doi:10.1109/tdei.2024.3379954 · Cited by 15
Yang, L., Cheng, Z., Cheng, L., & Liao, R. (2023) · High Voltage · doi:10.1049/hve2.12385 · Cited by 15
Ma, Z., Zhou, Y., Xia, J., He, X., Zhao, L., Shen, B., & Bian, X. (2022) · IEEE Transactions on Dielectrics and Electrical Insulation · doi:10.1109/tdei.2022.3191280 · Cited by 14
Metadata
- Authors
- Thind, B. S., Thomas, A. J., & Reddy, C. C.
- Affiliations
- Indian Institute of Technology Ropar (IN)
- Venue
- IEEE Transactions on Power Delivery
- Published
- 2021-10
- Volume
- 36
- Issue
- 5
- Pages
- 3101-3108
- ISSN
- 0885-8977 (ISSN-L)
- 1937-4208
- OpenAlex
- W3094445983
- Semantic Scholar
- 0196e335dbaf43c5d54a5f893c40b77e0a13c599
- Cited by
- 18
- References
- 17
- Citations by year
- 2026: 1 · 2025: 3 · 2024: 3 · 2023: 3 · 2022: 5 · 2021: 3
- FWCI
- 1.07
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- Locations
- IEEE Transactions on Power Delivery (publishedVersion)
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › High voltage insulation and dielectric phenomena
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Power Transformer Diagnostics and Insulation
- Physical Sciences › Engineering › Electrical and Electronic Engineering › HVDC Systems and Fault Protection
- Keywords
- HVDC converter transformer, voltage waveform, voltage harmonics, HVDC transmission
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Effect of Voltage Waveforms of HVDC Converter Transformer on Lifetime Characteristics. https://app.cochat.ai/papers/10.1109/tpwrd.2020.3033447
- The paper
- Thind, B. S., Thomas, A. J., & Reddy, C. C. (2021). Effect of Voltage Waveforms of HVDC Converter Transformer on Lifetime Characteristics. IEEE Transactions on Power Delivery. https://doi.org/10.1109/tpwrd.2020.3033447
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.