CoChat

Effect of supply voltage frequency on testing of insulation system

Cavallini, A., Montanari, G.C. · 2006 · IEEE Transactions on Dielectrics and Electrical Insulation

The DOI matches its Crossref record; 19 of the 20 references it cites were found in a registry or an index.

Abstract

This paper deals with the effect of supply frequency on partial discharge phenomena. Results of measurements performed on artificial and practical test objects are compared with computer simulations based on physical models. This comparative analysis points out and explains the differences in partial discharge phenomena observed in tests performed at different frequencies (from 0.1 to 300 Hz). The consequences associated to the use of different supply frequencies in practical applications are, eventually, outlined.

Overview

Integrity signals

Registry

Crossref · 10.1109/tdei.2006.1593409

Cites

19 of 19 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 19 references

Research works printed but not linked: 5

  1. morshuis, 1993, Partial Discharge Mechanisms
  2. 2001, IEC 60270 Partial Discharge Measurements
  3. meunier, 2000, Characterization of charge carrier traps in polymeric insulations, IEEE CEIDP, 21
  4. 1974, Recommended Practice for Insulation Testing of Large AC Rotating Machinery with High Voltage at Very Low Frequency
  5. 1992, IEEE Std C57 125 IEEE guide for failure investigation documentation and analysis for power transformers and shunt reactors

Cited by

See all 144

Metadata

Authors
Cavallini, A., & Montanari, G. C.
Affiliations
University of Bologna (IT)
Venue
IEEE Transactions on Dielectrics and Electrical Insulation
Published
2006-02
Volume
13
Issue
1
Pages
111-121
ISSN
1070-9878 (ISSN-L)
OpenAlex
W2116983999
Cited by
144
References
20
Citations by year
2026: 1 · 2025: 6 · 2024: 2 · 2023: 11 · 2022: 15 · 2021: 11 · 2020: 12 · 2019: 11 · 2018: 11 · 2017: 11 · 2016: 5 · 2015: 4 · 2014: 4 · 2013: 5 · 2012: 10
FWCI
3.06
Type
journal article
Language
en
Open access
closed
Locations
  • IEEE Transactions on Dielectrics and Electrical Insulation (publishedVersion)
  • Archivio istituzionale della ricerca (Alma Mater Studiorum Università di Bologna) (submittedVersion)
Topics
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › High voltage insulation and dielectric phenomena
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Power Transformer Diagnostics and Insulation
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Electrical and Electromagnetic Research
Keywords
supply frequency, partial discharge, insulation systems, high-frequency measurement, physical modeling, computer simulation, insulation testing

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Effect of supply voltage frequency on testing of insulation system. https://app.cochat.ai/papers/10.1109/tdei.2006.1593409
The paper
Cavallini, A., & Montanari, G. C. (2006). Effect of supply voltage frequency on testing of insulation system. IEEE Transactions on Dielectrics and Electrical Insulation. https://doi.org/10.1109/tdei.2006.1593409

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.