The Inertial Response of Induction-Machine-Based Wind Turbines
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
The inertial response of a generator is influenced by the sensitivity of the generator's electromagnetic torque to changes in the power system frequency. This paper deals with the inertial response of wind turbines employing induction-machine-based generators. A model of a field-oriented controlled doubly fed induction generator based on a fifth-order induction-generator model is described. The proposed model is implemented in a reference frame that allows the factors affecting the inertial response of a doubly fed induction generator to be easily examined. A comparison between the inertial response of a squirrel-cage and doubly fed induction-machine-based wind-turbine generator is performed using the developed models. It is found that the inertial response of a doubly fed induction generator employing field-oriented control is strongly influenced by the rotor current-controller bandwidth.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Power System Stability and Control
Kundur, P. (1994) · Cited by 19,639
Pena, R., Clare, J. C., & Asher, G. M. (1996) · IEE Proceedings - Electric Power Applications · doi:10.1049/ip-epa:19960288 · Cited by 2,759
Modeling and control of a wind turbine driven doubly fed induction generator
Tapia, A., Tapia, G., Ostolaza, J. X., & Saenz, J. R. (2003) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2003.811727 · Cited by 811
DC-bus voltage control of three-phase AC/DC PWM converters using feedback linearization
Lee, D.-C., Lee, G.-M., & Lee, K.-D. (2000) · IEEE Transactions on Industry Applications · doi:10.1109/28.845058 · Cited by 318
Development and experimental identification of dynamic models for wind turbines
Welfonder, E., Neifer, R., & Spanner, M. (1997) · Control Engineering Practice · doi:10.1016/s0967-0661(96)00208-0 · Cited by 93
Comparison of reduced-order dynamic models of induction machines
Thiringer, T., & Luomi, J. (2001) · IEEE Transactions on Power Systems · doi:10.1109/59.910789 · Cited by 89
New current control concept-minimum time current control in the three-phase PWM converter
Chui, J.-W., & Sui, S.-K. (1997) · IEEE Transactions on Power Electronics · doi:10.1109/63.554177 · Cited by 80
Cited by
Definition and Classification of Power System Stability – Revisited & Extended
Hatziargyriou, N., Milanovic, J., Rahmann, C., Ajjarapu, V., Canizares, C., Erlich, I., Hill, D., Hiskens, I., Kamwa, I., Pal, B., et al. (2021) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2020.3041774 · Cited by 1,244
Overview of Multi-MW Wind Turbines and Wind Parks
Liserre, M., Cardenas, R., Molinas, M., & Rodriguez, J. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2103910 · Cited by 876
Frequency Control and Wind Turbine Technologies
Lalor, G., Mullane, A., & O'Malley, M. (2005) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2005.857393 · Cited by 698
Self-citationOverview of Control Systems for the Operation of DFIGs in Wind Energy Applications
Cardenas, R., Pena, R., Alepuz, S., & Asher, G. (2013) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2013.2243372 · Cited by 670
Renewable energy sources and frequency regulation: survey and new perspectives
Bevrani, H., Ghosh, A., & Ledwich, G. (2010) · IET Renewable Power Generation · doi:10.1049/iet-rpg.2009.0049 · Cited by 574
Frequency support from doubly fed induction generator wind turbines
Ramtharan, G., Jenkins, N., & Ekanayake, J. B. (2007) · IET Renewable Power Generation · doi:10.1049/iet-rpg:20060019 · Cited by 530
Overview of control systems for the operation of DFIGs in wind energy applications
Pena, R., Cardenas, R., & Asher, G. (2013) · IECON 2013 - 39th Annual Conference of the IEEE Industrial Electronics Society · doi:10.1109/iecon.2013.6699116 · Cited by 529
Dynamic Contribution of DFIG-Based Wind Plants to System Frequency Disturbances
Kayikci, M., & Milanovic, J. V. (2009) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2009.2016062 · Cited by 462
Stochastic Optimization Model to Study the Operational Impacts of High Wind Penetrations in Ireland
Meibom, P., Barth, R., Hasche, B., Brand, H., Weber, C., & O'Malley, M. (2011) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2010.2070848 · Cited by 344
Self-citationMohseni, M., & Islam, S. M. (2012) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2012.03.039 · Cited by 327
An Assessment of the Impact of Wind Generation on System Frequency Control
Doherty, R., Mullane, A., Nolan, G., Burke, D. J., Bryson, A., & O'Malley, M. (2010) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2009.2030348 · Cited by 281
Self-citationGovernor Rate-Constrained OPF for Primary Frequency Control Adequacy
Chavez, H., Baldick, R., & Sharma, S. (2014) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2014.2298838 · Cited by 254
Integration of Renewable Energy into Present and Future Energy Systems
Sims, R., Mercado, P., Krewitt, W., Bhuyan, G., Flynn, D., Holttinen, H., Jannuzzi, G., Khennas, S., Liu, Y., Nilsson, L. J., et al. (2011) · Renewable Energy Sources and Climate Change Mitigation · doi:10.1017/cbo9781139151153.012 · Cited by 98
Self-citation
Metadata
- Authors
- Mullane, A., & O'Malley, M.
- Venue
- IEEE Transactions on Power Systems
- Published
- 2005-08
- Volume
- 20
- Issue
- 3
- Pages
- 1496-1503
- ISSN
- 0885-8950 (ISSN-L)
- OpenAlex
- W2162493407
- Cited by
- 309
- References
- 7
- FWCI
- 11.12
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.