The DOI matches its Crossref record.
Placement of PMUs to Enable Bad Data Detection in State Estimation
Abstract
As the phasor measurement units (PMUs) start populating the substations, their benefits for different power system application functions are being debated. One of these functions is the bad data processing that is commonly integrated into the state estimation. Bad data detection is closely related to the measurement redundancy in that bad data appearing in critical measurements cannot be detected. Such measurements, however, can be transformed into redundant measurements by adding few PMUs at strategic locations. In this paper, it will be shown that with few extra PMUs, the bad data detection and identification capability of a given system can be drastically improved. Description of the placement algorithm is given, and case studies carried out on different size test systems are presented
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
False data injection attacks against state estimation in electric power grids
Liu, Y., Ning, P., & Reiter, M. K. (2009) · Proceedings of the 16th ACM conference on Computer and communications security · doi:10.1145/1653662.1653666 · Cited by 1,285
Contingency-Constrained PMU Placement in Power Networks
Aminifar, F., Khodaei, A., Fotuhi-Firuzabad, M., & Shahidehpour, M. (2010) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2009.2036470 · Cited by 400
Optimal Placement of Phasor Measurement Units Using Immunity Genetic Algorithm
Aminifar, F., Lucas, C., Khodaei, A., & Fotuhi-Firuzabad, M. (2009) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2009.2014030 · Cited by 310
Synchrophasor Measurement Technology in Power Systems: Panorama and State-of-the-Art
Aminifar, F., Fotuhi-Firuzabad, M., Safdarian, A., Davoudi, A., & Shahidehpour, M. (2014) · IEEE Access · doi:10.1109/access.2015.2389659 · Cited by 261
False data attack models, impact analyses and defense strategies in the electricity grid
Liu, X., & Li, Z. (2017) · The Electricity Journal · doi:10.1016/j.tej.2017.04.001 · Cited by 57
Metadata
- Authors
- Chen, J., & Abur, A.
- Venue
- IEEE Transactions on Power Systems
- Published
- 2006-11
- Volume
- 21
- Issue
- 4
- Pages
- 1608-1615
- ISSN
- 0885-8950 (ISSN-L)
- OpenAlex
- W2096943410
- Cited by
- 387
- References
- 0
- FWCI
- 8.77
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Placement of PMUs to Enable Bad Data Detection in State Estimation. https://app.cochat.ai/papers/10.1109/tpwrs.2006.881149
- The paper
- Chen, J., & Abur, A. (2006). Placement of PMUs to Enable Bad Data Detection in State Estimation. IEEE Transactions on Power Systems. https://doi.org/10.1109/tpwrs.2006.881149
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.