In this paper, a model for the optimal placement of contingency-constrained phasor measurement units (PMUs) in electric power networks is presented. The conventional complete observability of power networks is first formulated and then, different contingency conditions in power networks including measurement losses and line outages are added to the main model. The communication constraints which would limit the maximum number of measurements associated with each installed PMU is considered as measurement limitations. The relevant formulations are also proposed to make the model more comprehensive. The IEEE standard test systems are examined for the applicability of proposed model. The comparison of presented results with those of other methods is presented which would justify the effectiveness of proposed model with regards to minimizing the total number of PMUs and the execution time. A large-scale system with 2383 buses is also analyzed to exhibit the applicability of proposed model to practical power system cases.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Abur, A., & Expósito, A. G. (2004) · CRC Press eBooks · doi:10.1201/9780203913673 · Cited by 2,974
Power system observability with minimal phasor measurement placement
Baldwin, T. L., Mili, L., Boisen, M. B., & Adapa, R. (1993) · IEEE Transactions on Power Systems · doi:10.1109/59.260810 · Cited by 818
Observability analysis and measurement placement for systems with PMUs
Xu, B., & Abur, A. (2005) · IEEE PES Power Systems Conference and Exposition · doi:10.1109/psce.2004.1397683 · Cited by 524
Generalized Integer Linear Programming Formulation for Optimal PMU Placement
Gou, B. (2008) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2008.926475 · Cited by 518
Placement of PMUs to Enable Bad Data Detection in State Estimation
Chen, J., & Abur, A. (2006) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2006.881149 · Cited by 387
Power System Frequency Monitoring Network (FNET) Implementation
Zhong, Z., Xu, C., Billian, B. J., Zhang, L., Tsai, S.-J. S., Conners, R. W., Centeno, V. A., Phadke, A. G., & Liu, Y. (2005) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2005.857386 · Cited by 346
Optimal Placement of Phasor Measurement Units Using Immunity Genetic Algorithm
Aminifar, F., Lucas, C., Khodaei, A., & Fotuhi-Firuzabad, M. (2009) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2009.2014030 · Cited by 310
Self-citationOptimal PMU placement for full network observability using Tabu search algorithm
Peng, J., Sun, Y., & Wang, H. F. (2006) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2005.05.005 · Cited by 283
Cited by
A survey on smart grid technologies and applications
Dileep, G. (2020) · Renewable Energy · doi:10.1016/j.renene.2019.08.092 · Cited by 1,020
Synchrophasor Measurement Technology in Power Systems: Panorama and State-of-the-Art
Aminifar, F., Fotuhi-Firuzabad, M., Safdarian, A., Davoudi, A., & Shahidehpour, M. (2014) · IEEE Access · doi:10.1109/access.2015.2389659 · Cited by 261
Self-citationJiang, H., Dai, X., Gao, D. W., Zhang, J. J., Zhang, Y., & Muljadi, E. (2016) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2016.2552229 · Cited by 56
Metadata
- Authors
- Aminifar, F., Khodaei, A., Fotuhi-Firuzabad, M., & Shahidehpour, M.
- Venue
- IEEE Transactions on Power Systems
- Published
- 2010-02
- Volume
- 25
- Issue
- 1
- Pages
- 516-523
- ISSN
- 0885-8950 (ISSN-L)
- 1558-0679
- OpenAlex
- W2133238120
- Cited by
- 400
- References
- 8
- FWCI
- 13.46
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Contingency-Constrained PMU Placement in Power Networks. https://app.cochat.ai/papers/10.1109/tpwrs.2009.2036470
- The paper
- Aminifar, F., Khodaei, A., Fotuhi-Firuzabad, M., & Shahidehpour, M. (2010). Contingency-Constrained PMU Placement in Power Networks. IEEE Transactions on Power Systems. https://doi.org/10.1109/tpwrs.2009.2036470
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.