Optimizing a Battery Energy Storage System for Frequency Control Application in an Isolated Power System
Open accessThe DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
This paper presents a method for optimal sizing and operation of a battery energy storage system (BESS) used for spinning reserve in a small isolated power system. Numerical simulations are performed on a load-frequency control (LFC) dynamic simulator of the isolated network. A novel control algorithm using adjustable state of charge limits is implemented and tested on a BESS dynamic model. An optimal sizing procedure of the BESS is developed for an isolated power system in order to achieve highest expected profitability of the device. The BESS can increase significantly the power system stability, the grid security, and the planning flexibility for a small isolated power system with low grid inertia. Meanwhile, it fulfills the frequency control requirements with a high expected economic profitability.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Power System Stability and Control
Kundur, P. (1994) · Cited by 19,639
Optimizing a Battery Energy Storage System for Primary Frequency Control
Oudalov, A., Chartouni, D., & Ohler, C. (2007) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2007.901459 · Cited by 536
Self-citationValue Analysis of Battery Energy Storage Applications in Power Systems
Oudalov, A., Chartouni, D., Ohler, C., & Linhofer, G. (2006) · 2006 IEEE PES Power Systems Conference and Exposition · doi:10.1109/psce.2006.296284 · Cited by 219
Self-citationLu, C., Liu, C., & Wu, C. (1995) · IEEE Transactions on Energy Conversion · doi:10.1109/60.464882 · Cited by 157
An object-oriented power plant adaptive control system design tool
Lu, S., Swidenbank, E., & Hogg, B. W. (1995) · IEEE Transactions on Energy Conversion · doi:10.1109/60.464888 · Cited by 54
Cited by
Luo, X., Wang, J., Dooner, M., & Clarke, J. (2015) · Applied Energy · doi:10.1016/j.apenergy.2014.09.081 · Cited by 3,869
Control of Power Converters in AC Microgrids
Rocabert, J., Luna, A., Blaabjerg, F., & Rodríguez, P. (2012) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2012.2199334 · Cited by 3,723
A review of energy storage technologies for wind power applications
Díaz-González, F., Sumper, A., Gomis-Bellmunt, O., & Villafáfila-Robles, R. (2012) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2012.01.029 · Cited by 1,547
Das, C. K., Bass, O., Kothapalli, G., Mahmoud, T. S., & Habibi, D. (2018) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2018.03.068 · Cited by 656
Kim, J.-Y., Jeon, J.-H., Kim, S.-K., Cho, C., Park, J. H., Kim, H.-M., & Nam, K.-Y. (2010) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2010.2073488 · Cited by 468
Metadata
- Authors
- Mercier, P., Cherkaoui, R., & Oudalov, A.
- Venue
- IEEE Transactions on Power Systems
- Published
- 2009-08
- Volume
- 24
- Issue
- 3
- Pages
- 1469-1477
- ISSN
- 0885-8950 (ISSN-L)
- 1558-0679
- OpenAlex
- W2116525489
- Cited by
- 498
- References
- 5
- FWCI
- 9.02
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.