The DOI matches its Crossref record.
Interconnection of Two Very Weak AC Systems by VSC-HVDC Links Using Power-Synchronization Control
Abstract
In this paper, voltage-source converter (VSC) based high-voltage dc (HVDC) transmission is investigated for interconnection of two very weak ac systems. By using the recently proposed power-synchronization control, the short-circuit capacities of the ac systems are no longer the limiting factors, but rather the load angles. For the analysis of the stability, the Jacobian transfer matrix concept has been introduced. The right-half plane (RHP) transmission zero of the ac Jacobian transfer matrix moves closer to the origin with larger load angles. The paper shows that, due to the bandwidth limitation imposed by the RHP zero on the direct-voltage control of the VSC, high dc-capacitance values are needed for such applications. In addition, the paper proposes a control structure particularly designed for weak-ac-system interconnections. As an example, it is shown that the proposed control structure enables a power transmission of 0.86 p.u. from a system with the short-circuit ratio (SCR) of 1.2 to a system with an SCR of 1.0. This should be compared to previous results for VSC based HVDC using vector current control. In this case, only 0.4 p.u. power transmission can be achieved for dc link where only one of the ac systems has an SCR of 1.0.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Subsynchronous Interaction Between Direct-Drive PMSG Based Wind Farms and Weak AC Networks
Liu, H., Xie, X., He, J., Xu, T., Yu, Z., Wang, C., & Zhang, C. (2017) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2017.2682197 · Cited by 623
Current Limiting Control With Enhanced Dynamics of Grid-Forming Converters During Fault Conditions
Taul, M. G., Wang, X., Davari, P., & Blaabjerg, F. (2020) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2019.2931477 · Cited by 466
Integration of Large Photovoltaic and Wind System by Means of Smart Transformer
Zhu, R., De Carne, G., Deng, F., & Liserre, M. (2017) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2017.2701758 · Cited by 71
Grid support functionalities based on modular multilevel converters with synchronous power control
Verdugo, C., Candela, J. I., & Rodriguez, P. (2016) · 2016 IEEE International Conference on Renewable Energy Research and Applications (ICRERA) · doi:10.1109/icrera.2016.7884399 · Cited by 23
Metadata
- Authors
- Zhang, L., Harnefors, L., & Nee, H.-P.
- Venue
- IEEE Transactions on Power Systems
- Published
- 2011-02
- Volume
- 26
- Issue
- 1
- Pages
- 344-355
- ISSN
- 0885-8950 (ISSN-L)
- 1558-0679
- OpenAlex
- W2142672517
- Cited by
- 452
- References
- 0
- FWCI
- 9.22
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Interconnection of Two Very Weak AC Systems by VSC-HVDC Links Using Power-Synchronization Control. https://app.cochat.ai/papers/10.1109/tpwrs.2010.2047875
- The paper
- Zhang, L., Harnefors, L., & Nee, H.-P. (2011). Interconnection of Two Very Weak AC Systems by VSC-HVDC Links Using Power-Synchronization Control. IEEE Transactions on Power Systems. https://doi.org/10.1109/tpwrs.2010.2047875
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.