Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 623

The DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.

Subsynchronous Interaction Between Direct-Drive PMSG Based Wind Farms and Weak AC Networks

Liu, Huakun, Xie, Xiaorong, He, Jingbo, Xu, Tao, Yu, Zhao, Wang, Chao, Zhang, Chuanyu·2017·IEEE Transactions on Power Systems

Abstract

Recently, sustained power oscillation at subsynchronous frequency was captured in direct-drive permanent magnetic synchronous generator (PMSG) based wind farms in Xinjiang Uygur Autonomous Region, China. This new type of subsynchronous interaction (SSI) detected in practical systems has never been reported and analyzed before. Therefore, its mechanism and characteristics are not yet clearly clarified. In this paper, a simplified but representative system model with multiple PMSGs interfaced with AC networks is established first based on the actual system and the PMSG model provided by the manufacturer. Then, small-signal eigenanalysis, time-domain simulation, and impedance model analysis are carried out to investigate the interactive dynamics between them. The results show that such interaction between direct-drive PMSG wind farms and weak ac grids characterized by low short-circuit ratio would cause negative-resistance effect for the SSI mode, leading to unstable oscillation. In such cases, the controller of PMSG would saturate soon, resulting in sustained power oscillation in the system. If unfortunately the oscillation frequency matches the torsional mode of any nearby turbogenerator, severe torsional vibration would be excited on the shaft of the latter. The analysis results are finally validated with field measurements of an actual SSI event. To address the problem, a supplementary subsynchronous damping control loop is attached to the controllers of PMSGs to reshape the impedance and thus to stabilize the SSI.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tpwrs.2017.2682197

Cites

17 of 17 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 17 references

Cited by

See all 623

Metadata

Authors
Liu, H., Xie, X., He, J., Xu, T., Yu, Z., Wang, C., & Zhang, C.
Venue
IEEE Transactions on Power Systems
Published
2017-11
Volume
32
Issue
6
Pages
4708-4720
ISSN
  • 0885-8950 (ISSN-L)
  • 1558-0679
OpenAlex
W2595551762
Cited by
623
References
17
FWCI
20.03
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Subsynchronous Interaction Between Direct-Drive PMSG Based Wind Farms and Weak AC Networks. https://app.cochat.ai/papers/10.1109/tpwrs.2017.2682197
The paper
Liu, H., Xie, X., He, J., Xu, T., Yu, Z., Wang, C., & Zhang, C. (2017). Subsynchronous Interaction Between Direct-Drive PMSG Based Wind Farms and Weak AC Networks. IEEE Transactions on Power Systems. https://doi.org/10.1109/tpwrs.2017.2682197

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.