The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Transition From Islanded to Grid-Connected Mode of Microgrids With Voltage-Based Droop Control
Open accessAbstract
Microgrids are able to provide a coordinated integration of the increasing share of distributed generation (DG) units in the network. The primary control of the DG units is generally performed by droop-based control algorithms that avoid communication. The voltage-based droop (VBD) control is developed for islanded low-voltage microgrids with a high share of renewable energy sources. With VBD control, both dispatchable and less-dispatchable units will contribute in the power sharing and balancing. The priority for power changes is automatically set dependent on the terminal voltages. In this way, the renewables change their output power in more extreme voltage conditions compared to the dispatchable units, hence, only when necessary for the reliability of the network. This facilitates the integration of renewable units and improves the reliability of the network. This paper focusses on modifying the VBD control strategy to enable a smooth transition between the islanded and the grid-connected mode of the microgrid. The VBD control can operate in both modes. Therefore, for islanding, no specific measures are required. To reconnect the microgrid to the utility network, the modified VBD control synchronizes the voltage of a specified DG unit with the utility voltage. It is shown that this synchronization procedure significantly limits the switching transient and enables a smooth mode transfer.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Guerrero, J. M., Vasquez, J. C., Matas, J., de Vicuna, L. G., & Castilla, M. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2066534 · Cited by 5,075
Cited by
State of the Art in Research on Microgrids: A Review
Parhizi, S., Lotfi, H., Khodaei, A., & Bahramirad, S. (2015) · IEEE Access · doi:10.1109/access.2015.2443119 · Cited by 1,194
Grid-Forming Converters: Control Approaches, Grid-Synchronization, and Future Trends—A Review
Rosso, R., Wang, X., Liserre, M., Lu, X., & Engelken, S. (2021) · IEEE Open Journal of Industry Applications · doi:10.1109/ojia.2021.3074028 · Cited by 1,187
Overview of Power Management Strategies of Hybrid AC/DC Microgrid
Nejabatkhah, F., & Li, Y. W. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2014.2384999 · Cited by 986
Grid Forming Inverter Modeling, Control, and Applications
Rathnayake, D. B., Akrami, M., Phurailatpam, C., Me, S. P., Hadavi, S., Jayasinghe, G., Zabihi, S., & Bahrani, B. (2021) · IEEE Access · doi:10.1109/access.2021.3104617 · Cited by 630
Battery‐supercapacitor hybrid energy storage system in standalone DC microgrids: areview
Jing, W., Hung Lai, C., Wong, S. H. W., & Wong, M. L. D. (2017) · IET Renewable Power Generation · doi:10.1049/iet-rpg.2016.0500 · Cited by 413
Metadata
- Authors
- Vandoorn, T. L., Meersman, B., Kooning, D., & Vandevelde, L.
- Venue
- IEEE Transactions on Power Systems
- Published
- 2013-08
- Volume
- 28
- Issue
- 3
- Pages
- 2545-2553
- ISSN
- 0885-8950 (ISSN-L)
- 1558-0679
- OpenAlex
- W2021038145
- Cited by
- 221
- References
- 1
- FWCI
- 23.24
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Transition From Islanded to Grid-Connected Mode of Microgrids With Voltage-Based Droop Control. https://app.cochat.ai/papers/10.1109/tpwrs.2012.2226481
- The paper
- Vandoorn, T. L., Meersman, B., Kooning, D., & Vandevelde, L. (2013). Transition From Islanded to Grid-Connected Mode of Microgrids With Voltage-Based Droop Control. IEEE Transactions on Power Systems. https://doi.org/10.1109/tpwrs.2012.2226481
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.