Quasi-Monte Carlo Based Probabilistic Small Signal Stability Analysis for Power Systems With Plug-In Electric Vehicle and Wind Power Integration
The DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.
Abstract
This work presents a new quasi-Monte Carlo (QMC) based probabilistic small signal stability analysis (PSSSA) method to assess the dynamic effects of plug-in electric vehicles (PEVs) and wind energy conversion systems (WECSs) in power systems. The detailed dynamic model of PEVs is first proposed for stability study. To account for the stochastic behavior of PEVs and WECSs in load flow studies, the randomized model and probability density function (PDF) representing their nodal power injections are first developed, and then their stochastic injections are sampled by Sobol sequences. Finally, the distribution of system eigenvalues can be obtained by the PSSSA. The proposed QMC-based PSSSA is tested on the modified 2-area 4-machine system and New England 10-generator 39-bus system. Results showed the necessity of modeling of PEVs and WECSs, and validated the efficiency of the proposed QMC.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Power System Stability and Control
Kundur, P. (1994) · Cited by 19,639
Power system dynamics : stability and control
Machowski, J., Bialek, J. W., & Bumby, J. R. (2008) · Durham Research Online (Durham University) · Cited by 2,348
Kempton, W., & Tomić, J. (2005) · Journal of Power Sources · doi:10.1016/j.jpowsour.2004.12.022 · Cited by 2,126 · cited 1×
“The usage of plug-in electric vehicle (PEV) has been recognized as a promising means not only to reduce emissions by automobiles but also to relieve the operational problems caused by the intermittent characteristic of wind energy [1].”
BackgroundStott, B., & Alsac, O. (1974) · IEEE Transactions on Power Apparatus and Systems · doi:10.1109/tpas.1974.293985 · Cited by 1,522 · cited 2×
“Fast decoupled load flow (FDLF) [34] method is employed.”
MethodModeling of Load Demand Due to EV Battery Charging in Distribution Systems
Qian, K., Zhou, C., Allan, M., & Yuan, Y. (2011) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2010.2057456 · Cited by 1,268 · cited 2×
“On the other hand, the usage of vehicles also show stochastic characteristics due to the different driving times and distances [16] and, therefore, state-of-charge (SOC) of the battery is a random factor when the PEV plugs into the grid.”
BackgroundDevelopment of an Optimal Vehicle-to-Grid Aggregator for Frequency Regulation
Han, S., Han, S., & Sezaki, K. (2010) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2010.2045163 · Cited by 1,086
Gautam, D., Vittal, V., & Harbour, T. (2009) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2009.2021234 · Cited by 680 · cited 1×
“However, DFIG affects the dynamic behavior of the systems [14].”
BackgroundNew dynamical models of lead-acid batteries
Ceraolo, M. (2000) · IEEE Transactions on Power Systems · doi:10.1109/59.898088 · Cited by 584 · cited 1×
“3) Battery of PEVs: A third-order model of lead-acid batteries has been developed and validated for analysis of electrical system in [25], so it is used for the study in this paper, as follows:”
MethodModeling of Plug-in Hybrid Electric Vehicle Charging Demand in Probabilistic Power Flow Calculations
Li, G., & Zhang, X.-P. (2012) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2011.2172643 · Cited by 434 · cited 1×
“In other words, the serviced time of each customer is equal to the time after arrival, which follows exponential distribution with mean [29]:”
BackgroundThe impact of large scale wind power generation on power system oscillations
Slootweg, J. G., & Kling, W. L. (2003) · Electric Power Systems Research · doi:10.1016/s0378-7796(03)00089-0 · Cited by 392 · cited 1×
“Its effect on stability is unlike synchronous generators; DFIG does not engage in oscillation modes since its generator model does not show the swing behavior between rotor angle and speed [13].”
Background
Cited by
Utilization of Electric Vehicles for Vehicle-to-Grid Services: Progress and Perspectives
Ravi, S. S., & Aziz, M. (2022) · Energies · doi:10.3390/en15020589 · Cited by 309
Hasan, K. N., Preece, R., & Milanović, J. V. (2019) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2018.10.027 · Cited by 217
Reliability Evaluation of Distribution Systems Including Vehicle-to-Home and Vehicle-to-Grid
Xu, N. Z., & Chung, C. Y. (2016) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2015.2396524 · Cited by 197
“To further improve the efficiency and the speed of convergence, advanced sampling methods [4], [31] can be used in future works.”
BackgroundMethodSelf-citation
Metadata
- Authors
- Wong, W. C., Chung, C. Y., Chan, K. W., & Chen, H.
- Venue
- IEEE Transactions on Power Systems
- Published
- 2013-08
- Volume
- 28
- Issue
- 3
- Pages
- 3335-3343
- ISSN
- 0885-8950 (ISSN-L)
- 1558-0679
- OpenAlex
- W2085545731
- Cited by
- 169
- References
- 20
- FWCI
- 5.59
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.