The DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.
Distribution Voltage Control Considering the Impact of PV Generation on Tap Changers and Autonomous Regulators
Abstract
The uptake of variable megawatts from photovoltaics (PV) challenges distribution system operation. The primary problem is significant voltage rise in the feeder that forces existing voltage control devices such as on-load tap-changers and line voltage regulators to operate continuously. The consequence is the deterioration of the operating life of the voltage control mechanism. Also, conventional non-coordinated reactive power control can result in the operation of the line regulator at its control limit (runaway condition). This paper proposes an optimal reactive power coordination strategy based on the load and irradiance forecast. The objective is to minimize the number of tap operations so as not to reduce the operating life of the tap control mechanism and avoid runaway. The proposed objective is achieved by coordinating various reactive power control options in the distribution network while satisfying constraints such as maximum power point tracking of PV and voltage limits of the feeder. The option of voltage support from PV plant is also considered. The problem is formulated as constrained optimization and solved through the interior point technique. The effectiveness of the approach is demonstrated in a realistic distribution network model.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Primal-Dual Interior-Point Methods
Wright, S. J. (1997) · Society for Industrial and Applied Mathematics eBooks · doi:10.1137/1.9781611971453 · Cited by 2,391
Distribution System Modeling and Analysis
Kersting, W. (2012) · Electric Power Engineering Series · doi:10.1201/b12056-31 · Cited by 1,241
Summary of Distributed Resources Impact on Power Delivery Systems
Walling, R. A., Saint, R., Dugan, R. C., Burke, J., & Kojovic, L. A. (2008) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2007.909115 · Cited by 1,024
Coordinated Active Power Curtailment of Grid Connected PV Inverters for Overvoltage Prevention
Tonkoski, R., Lopes, L. A. C., & El-Fouly, T. H. M. (2011) · IEEE Transactions on Sustainable Energy · doi:10.1109/tste.2010.2098483 · Cited by 822
Voltage rise: the big issue when connecting embedded generation to long 11 kV overhead lines
Masters, C. L. (2002) · Power Engineering Journal · doi:10.1049/pe:20020101 · Cited by 648
Solar PV Integration Challenges
Katiraei, F., & Aguero, J. (2011) · IEEE Power and Energy Magazine · doi:10.1109/mpe.2011.940579 · Cited by 550
Improved Low Voltage Grid-Integration of Photovoltaic Systems in Germany
Stetz, T., Marten, F., & Braun, M. (2013) · IEEE Transactions on Sustainable Energy · doi:10.1109/tste.2012.2198925 · Cited by 466
Three-phase power flow calculations using the current injection method
Garcia, P. A. N., Pereira, J. L. R., Carneiro, S., da Costa, V. M., & Martins, N. (2000) · IEEE Transactions on Power Systems · doi:10.1109/59.867133 · Cited by 438
Optimal Distribution Voltage Control and Coordination With Distributed Generation
Senjyu, T., Miyazato, Y., Yona, A., Urasaki, N., & Funabashi, T. (2008) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2007.908816 · Cited by 424
Distribution System Modeling and Analysis
Denny, F., & Dismukes, D. (2001) · Electric Power Engineering Series · doi:10.1201/9781420058451 · Cited by 362
Cited by
A review of key power system stability challenges for large-scale PV integration
Shah, R., Mithulananthan, N., Bansal, R. C., & Ramachandaramurthy, V. K. (2015) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2014.09.027 · Cited by 501
Li, P., Ji, H., Wang, C., Zhao, J., Song, G., Ding, F., & Wu, J. (2017) · IEEE Transactions on Sustainable Energy · doi:10.1109/tste.2017.2686009 · Cited by 447
Active Management of Low-Voltage Networks for Mitigating Overvoltages Due to Photovoltaic Units
Olivier, F., Aristidou, P., Ernst, D., & Van Cutsem, T. (2016) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2015.2410171 · Cited by 328
Methods and strategies for overvoltage prevention in low voltage distribution systems with PV
Hashemi, S., & Østergaard, J. (2017) · IET Renewable Power Generation · doi:10.1049/iet-rpg.2016.0277 · Cited by 212
On Estimation and Sensitivity Analysis of Distribution Circuit’s Photovoltaic Hosting Capacity
Dubey, A., & Santoso, S. (2017) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2016.2622286 · Cited by 151
Metadata
- Authors
- Agalgaonkar, Y. P., Pal, B. C., & Jabr, R. A.
- Venue
- IEEE Transactions on Power Systems
- Published
- 2014-01
- Volume
- 29
- Issue
- 1
- Pages
- 182-192
- ISSN
- 0885-8950 (ISSN-L)
- 1558-0679
- OpenAlex
- W2173817159
- Cited by
- 315
- References
- 19
- FWCI
- 13.38
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Distribution Voltage Control Considering the Impact of PV Generation on Tap Changers and Autonomous Regulators. https://app.cochat.ai/papers/10.1109/tpwrs.2013.2279721
- The paper
- Agalgaonkar, Y. P., Pal, B. C., & Jabr, R. A. (2014). Distribution Voltage Control Considering the Impact of PV Generation on Tap Changers and Autonomous Regulators. IEEE Transactions on Power Systems. https://doi.org/10.1109/tpwrs.2013.2279721
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.