Geometry of Power Flows and Optimization in Distribution Networks
Open accessThe DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
We investigate the geometry of injection regions and its relationship to optimization of power flows in tree networks. The injection region is the set of all vectors of bus power injections that satisfy the network and operation constraints. The geometrical object of interest is the set of Pareto-optimal points of the injection region. If the voltage magnitudes are fixed, the injection region of a tree network can be written as a linear transformation of the product of two-bus injection regions, one for each line in the network. Using this decomposition, we show that under the practical condition that the angle difference across each line is not too large, the set of Pareto-optimal points of the injection region remains unchanged by taking the convex hull. Moreover, the resulting convexified optimal power flow problem can be efficiently solved via semi-definite programming or second-order cone relaxations. These results improve upon earlier works by removing the assumptions on active power lower bounds. It is also shown that our practical angle assumption guarantees two other properties: 1) the uniqueness of the solution of the power flow problem and 2) the non-negativity of the locational marginal prices. Partial results are presented for the case when the voltage magnitudes are not fixed but can lie within certain bounds.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Distribution System Modeling and Analysis
Kersting, W. (2012) · Electric Power Engineering Series · doi:10.1201/b12056-31 · Cited by 1,241
Inverter VAR control for distribution systems with renewables
Farivar, M., Clarke, C. R., Low, S. H., & Chandy, K. M. (2011) · 2011 IEEE International Conference on Smart Grid Communications (SmartGridComm) · doi:10.1109/smartgridcomm.2011.6102366 · Cited by 331 · cited 2×
“First, the arguments used in [8]–[10] are algebraic and some used no n-trivial matrix fitting results and [13], [14] use algebraic SOCP relaxations, while the present paper uses en tirely elementary geometric arguments.”
MethodResultOn the existence and uniqueness of load flow solution for radial distribution power networks
Chiang, H.-D., & Baran, M. E. (1990) · IEEE Transactions on Circuits and Systems · doi:10.1109/31.52734 · Cited by 156
Geometry of injection regions of power networks
Zhang, B., & Tse, D. (2013) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2012.2208205 · Cited by 118
Self-citation
Cited by
A Survey of Distributed Optimization and Control Algorithms for Electric Power Systems
Molzahn, D. K., Dorfler, F., Sandberg, H., Low, S. H., Chakrabarti, S., Baldick, R., & Lavaei, J. (2017) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2017.2720471 · Cited by 1,273
Self-citationZero Duality Gap in Optimal Power Flow Problem
Lavaei, J., & Low, S. H. (2012) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2011.2160974 · Cited by 1,195
Self-citationConvex Relaxation of Optimal Power Flow—Part I: Formulations and Equivalence
Low, S. H. (2014) · IEEE Transactions on Control of Network Systems · doi:10.1109/tcns.2014.2309732 · Cited by 929
Network Equilibrium of Coupled Transportation and Power Distribution Systems
Wei, W., Wu, L., Wang, J., & Mei, S. (2018) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2017.2723016 · Cited by 360
An Optimal and Distributed Method for Voltage Regulation in Power Distribution Systems
Zhang, B., Lam, A. Y. S., Dominguez-Garcia, A. D., & Tse, D. (2015) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2014.2347281 · Cited by 325
Self-citationOptimal Dispatch of Photovoltaic Inverters in Residential Distribution Systems
Dall'Anese, E., Dhople, S. V., & Giannakis, G. B. (2014) · IEEE Transactions on Sustainable Energy · doi:10.1109/tste.2013.2292828 · Cited by 285
Strong SOCP Relaxations for the Optimal Power Flow Problem
Kocuk, B., Dey, S. S., & Sun, X. A. (2016) · Operations Research · doi:10.1287/opre.2016.1489 · Cited by 281
A Survey of Relaxations and Approximations of the Power Flow Equations
Molzahn, D. K., & Hiskens, I. A. (2019) · Foundations and Trends® in Electric Energy Systems · doi:10.1561/3100000012 · Cited by 272
Distributed Reactive Power Feedback Control for Voltage Regulation and Loss Minimization
Bolognani, S., Carli, R., Cavraro, G., & Zampieri, S. (2015) · IEEE Transactions on Automatic Control · doi:10.1109/tac.2014.2363931 · Cited by 252
AC-feasibility on tree networks is NP-hard
Lehmann, K., Grastien, A., & Van Hentenryck, P. (2016) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2015.2407363 · Cited by 221
Decentralized Optimal Dispatch of Photovoltaic Inverters in Residential Distribution Systems
Dall'Anese, E., Dhople, S. V., Johnson, B. B., & Giannakis, G. B. (2014) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2014.2357997 · Cited by 158
“Sufficient conditions for SDR to be successful in OPF-type problems are available for networks that are radial and balanced in [14], [20], whereas the virtu es of SDR for unbalanced medium- and low- voltage distribution systems have been demonstrated in [9].”
MethodResilience of Energy Infrastructure and Services: Modeling, Data Analytics, and Metrics
Ji, C., Wei, Y., & Poor, H. V. (2017) · Proceedings of the IEEE · doi:10.1109/jproc.2017.2698262 · Cited by 91
Metadata
- Authors
- Lavaei, J., Tse, D., & Zhang, B.
- Venue
- IEEE Transactions on Power Systems
- Published
- 2014-03
- Volume
- 29
- Issue
- 2
- Pages
- 572-583
- ISSN
- 0885-8950 (ISSN-L)
- 1558-0679
- OpenAlex
- W2057057063
- Cited by
- 181
- References
- 4
- FWCI
- 11.98
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.