Review on Implementation and Assessment of Conservation Voltage Reduction
The DOI matches its Crossref record; 30 of the 30 references it cites were found in a registry or an index.
Abstract
Conservation voltage reduction (CVR) is widely adopted by utilities for peak demand reduction and energy savings through reducing the voltage level of the electrical distribution system. This paper presents an in-depth review on implementing and assessing CVR. The methodologies to quantify CVR effects are categorized into comparison-based, regression-based, synthesis-based and simulation-based methods. The implementation strategies for voltage reduction are classified into open-loop and closed-loop methods. The impacts of emerging smart-grid technologies on CVR are also discussed. The paper can provide researchers and utility engineers with further insights into the state of the art, technical barriers and future research directions of CVR technologies.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A New Heuristic Optimization Algorithm: Harmony Search
Geem, Z. W., Kim, J. H., & Loganathan, G. V. (2001) · SIMULATION · doi:10.1177/003754970107600201 · Cited by 6,247
Power-Electronic Systems for the Grid Integration of Renewable Energy Sources: A Survey
Carrasco, J. M., Franquelo, L. G., Bialasiewicz, J. T., Galvan, E., PortilloGuisado, R. C., Prats, M. A. M., Leon, J. I., & Moreno-Alfonso, N. (2006) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2006.878356 · Cited by 4,018
Neural networks for short-term load forecasting: a review and evaluation
Hippert, H. S., Pedreira, C. E., & Souza, R. C. (2001) · IEEE Transactions on Power Systems · doi:10.1109/59.910780 · Cited by 2,221
Electric load forecasting using an artificial neural network
Park, D.-C., El-Sharkawi, M. A., Marks, R. J., Atlas, L., & Damborg, M. J. (1991) · IEEE Transactions on Power Systems · doi:10.1109/59.76685 · Cited by 1,440
Load Forecasting Using Support Vector Machines: A Study on EUNITE Competition 2001
Chen, B.-J., Chang, M.-W., & Lin, C.-J. (2004) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2004.835679 · Cited by 841
Al Abri, R. S., El-Saadany, E. F., & Atwa, Y. M. (2013) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2012.2200049 · Cited by 488
Adaptive VAR Control for Distribution Circuits With Photovoltaic Generators
Yeh, H.-G., Gayme, D. F., & Low, S. H. (2012) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2012.2183151 · Cited by 458
A Method for Placement of DG Units in Distribution Networks
Hedayati, H., Nabavi-Niaki, S. A., & Akbarimajd, A. (2008) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2007.916106 · Cited by 438
Short-Term Load Forecasting Based on an Adaptive Hybrid Method
Fan, S., & Chen, L. (2006) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2005.860944 · Cited by 405
Inverter VAR control for distribution systems with renewables
Farivar, M., Clarke, C. R., Low, S. H., & Chandy, K. M. (2011) · 2011 IEEE International Conference on Smart Grid Communications (SmartGridComm) · doi:10.1109/smartgridcomm.2011.6102366 · Cited by 331 · cited 2×
“output requires a faster controller, such as an inverter [71]–[73].”
Load Representation in Power System Stability Studies
Concordia, C., & Ihara, S. (1982) · IEEE Transactions on Power Apparatus and Systems · doi:10.1109/tpas.1982.317163 · Cited by 326
An Improved Multi-Objective Harmony Search for Optimal Placement of DGs in Distribution Systems
Nekooei, K., Farsangi, M. M., Nezamabadi-Pour, H., & Lee, K. Y. (2013) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2012.2237420 · Cited by 284
Niknam, T., Zare, M., & Aghaei, J. (2012) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2012.2209900 · Cited by 239
Volt/var control algorithm for modern distribution management system
Roytelman, I., Wee, B. K., & Lugtu, R. L. (1995) · IEEE Transactions on Power Systems · doi:10.1109/59.466504 · Cited by 193
Dynamic models of house heating based on equivalent thermal parameters
Sonderegger, R. C. (1978) · Cited by 122
Multi-State Load Models for Distribution System Analysis
Schneider, K. P., Fuller, J. C., & Chassin, D. P. (2011) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2011.2132154 · Cited by 116
Impact of Voltage Reduction on Energy and Demand
Preiss, R. F., & Warnock, V. J. (1978) · IEEE Transactions on Power Apparatus and Systems · doi:10.1109/tpas.1978.354658 · Cited by 110
Capacitor Placement for Conservative Voltage Reduction on Distribution Feeders
Milosevic, B., & Begovic, M. M. (2004) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2004.824400 · Cited by 110
Effects of distributed energy resources on conservation voltage reduction (CVR)
Singh, R., Tuffner, F., Fuller, J., & Schneider, K. P. (2011) · IEEE Power Engineering Society General Meeting · doi:10.1109/pes.2011.6039702 · Cited by 79
Analysis of Conservation Voltage Reduction Effects Based on Multistage SVR and Stochastic Process
Wang, Z., Begovic, M. M., & Wang, J. (2013) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2013.2279836 · Cited by 77
Self-citationWilson, T. L. (2010) · IEEE Power Engineering Society General Meeting · doi:10.1109/pes.2010.5589762 · Cited by 75
Conservation Voltage Reduction with feedback from Advanced Metering Infrastructure
Peskin, M. A., Powell, P. W., & Hall, E. J. (2012) · doi:10.1109/tdc.2012.6281644 · Cited by 71
A quantification of the energy savings by Conservation Voltage Reduction
Ellens, W., Berry, A., & West, S. (2012) · IEEE International Conference on Power System Technology · doi:10.1109/powercon.2012.6401391 · Cited by 67
BC Hydro's experience on Voltage VAR Optimization in distribution system
Dabic, V., Siew, C., Peralta, J., & Acebedo, D. (2010) · IEEE PES Transmission and Distribution Conference and Exhibition · doi:10.1109/tdc.2010.5484276 · Cited by 64
The Effects of Voltage Reduction on Distribution Circuit Loads
Erickson, J., & Gilligan, S. (1982) · IEEE Transactions on Power Apparatus and Systems · doi:10.1109/tpas.1982.317449 · Cited by 49
A coordinated optimization approach to Volt/VAr control for large power distribution networks
Krok, M. J., & Genç, Ş. (2011) · Proceedings of the ... American Control Conference/Proceedings of the American Control Conference · doi:10.1109/acc.2011.5991606 · Cited by 43
Energy conservation with voltage reduction-fact or fantasy
Wilson, T. L. (2003) · IEEE Rural Electric Power Conference (REPC) · doi:10.1109/repcon.2002.1002295 · Cited by 38
Integrating engineering and economic analysis for conservation voltage reduction
Fletcher, R. H., & Saeed, A. (2003) · IEEE Power Engineering Society Summer Meeting · doi:10.1109/pess.2002.1043401 · Cited by 25
Dugan, R. C., & McGranaghan, M. F. (2011) · IEEE Power and Energy Magazine · doi:10.1109/mpe.2011.941867 · Cited by 23
Neal, R. (2010) · IEEE PES Transmission and Distribution Conference and Exhibition · doi:10.1109/tdc.2010.5484402 · Cited by 19
Cited by
Arif, A., Wang, Z., Wang, J., Mather, B., Bashualdo, H., & Zhao, D. (2018) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2017.2700436 · Cited by 500
Self-citationA Review of Power System Flexibility With High Penetration of Renewables
Mohandes, B., Moursi, M. S. E., Hatziargyriou, N., & Khatib, S. E. (2019) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2019.2897727 · Cited by 496
Ferreira Costa, L., De Carne, G., Buticchi, G., & Liserre, M. (2017) · IEEE Power Electronics Magazine · doi:10.1109/mpel.2017.2692381 · Cited by 303
Wang, Z., Wang, J., Chen, B., Begovic, M. M., & He, Y. (2014) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2014.2329842 · Cited by 183
“outputs of renewable energy sources (RES)-based DGs [1], [2].”
BackgroundSelf-citationFrequency Control in Isolated/Islanded Microgrids Through Voltage Regulation
Farrokhabadi, M., Canizares, C. A., & Bhattacharya, K. (2017) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2015.2479576 · Cited by 168
Metadata
- Authors
- Wang, Z., & Wang, J.
- Venue
- IEEE Transactions on Power Systems
- Published
- 2014-05
- Volume
- 29
- Issue
- 3
- Pages
- 1306-1315
- ISSN
- 0885-8950 (ISSN-L)
- 1558-0679
- OpenAlex
- W2031329484
- Cited by
- 288
- References
- 30
- FWCI
- 13.97
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.