The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Grid-Synchronization Stability Improvement of Large Scale Wind Farm During Severe Grid Fault
Abstract
Loss of synchronization between wind farm and power grid during severe grid faults would cause wind farm tripping. In this paper, the mechanism of grid-synchronization is uncovered, described as motion of an autonomous nonlinear differential equation with specific initial states. The revealed mechanism indicates that even though steady-state working point exists, improper initial states and poor system dynamic properties could lead to synchronization instability. In order to keep wind farm synchronous with the power grid during severe grid faults, special requirements on system dynamic properties are stated. Moreover, to satisfy all the requirements, a current injecting method is proposed. By adjusting active and reactive output currents of the wind farm, the proposed method could ensure system synchronization stability during severe grid faults. Implementation of the proposed method on PMSG- and DFIG-based wind farm is illustrated. Simulation results validate the analysis and the control method.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(2005) · Wiley eBooks · doi:10.1002/0470012684 · Cited by 2,915
Decoupled Double Synchronous Reference Frame PLL for Power Converters Control
Rodriguez, P., Pou, J., Bergas, J., Candela, J. I., Burgos, R. P., & Boroyevich, D. (2007) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2006.890000 · Cited by 1,359
Power-Synchronization Control of Grid-Connected Voltage-Source Converters
Zhang, L., Harnefors, L., & Nee, H.-P. (2010) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2009.2032231 · Cited by 1,317
Ridethrough of Wind Turbines with Doubly-Fed Induction Generator During a Voltage Dip
Morren, J., & deHaan, S. W. H. (2005) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2005.845526 · Cited by 873
Zhou, J. Z., Ding, H., Fan, S., Zhang, Y., & Gole, A. M. (2014) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2014.2330518 · Cited by 738
Dong, D., Wen, B., Boroyevich, D., Mattavelli, P., & Xue, Y. (2015) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2014.2334665 · Cited by 709
Impedance-Based Analysis of Grid-Synchronization Stability for Three-Phase Paralleled Converters
Wen, B., Dong, D., Boroyevich, D., Burgos, R., Mattavelli, P., & Shen, Z. (2016) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2015.2419712 · Cited by 586
Interconnection of Two Very Weak AC Systems by VSC-HVDC Links Using Power-Synchronization Control
Zhang, L., Harnefors, L., & Nee, H.-P. (2011) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2010.2047875 · Cited by 452
Xin, H., Huang, L., Zhang, L., Wang, Z., & Hu, J. (2016) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2016.2521325 · Cited by 299
Cited by
Grid-Synchronization Stability of Converter-Based Resources—An Overview
Wang, X., Taul, M. G., Wu, H., Liao, Y., Blaabjerg, F., & Harnefors, L. (2020) · IEEE Open Journal of Industry Applications · doi:10.1109/ojia.2020.3020392 · Cited by 862
Current Limiting Control With Enhanced Dynamics of Grid-Forming Converters During Fault Conditions
Taul, M. G., Wang, X., Davari, P., & Blaabjerg, F. (2020) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2019.2931477 · Cited by 466
Design-Oriented Transient Stability Analysis of PLL-Synchronized Voltage-Source Converters
Wu, H., & Wang, X. (2020) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2019.2937942 · Cited by 454
Shair, J., Li, H., Hu, J., & Xie, X. (2021) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2021.111111 · Cited by 433
Taul, M. G., Wang, X., Davari, P., & Blaabjerg, F. (2019) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2019.2892142 · Cited by 415
Metadata
- Authors
- Ma, S., Geng, H., Liu, L., Yang, G., & Pal, B. C.
- Venue
- IEEE Transactions on Power Systems
- Published
- 2018-01
- Volume
- 33
- Issue
- 1
- Pages
- 216-226
- ISSN
- 0885-8950 (ISSN-L)
- 1558-0679
- OpenAlex
- W2610528666
- Cited by
- 261
- References
- 9
- FWCI
- 7.50
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Grid-Synchronization Stability Improvement of Large Scale Wind Farm During Severe Grid Fault. https://app.cochat.ai/papers/10.1109/tpwrs.2017.2700050
- The paper
- Ma, S., Geng, H., Liu, L., Yang, G., & Pal, B. C. (2018). Grid-Synchronization Stability Improvement of Large Scale Wind Farm During Severe Grid Fault. IEEE Transactions on Power Systems. https://doi.org/10.1109/tpwrs.2017.2700050
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.