The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Synchronous Instability Mechanism of P-f Droop-Controlled Voltage Source Converter Caused by Current Saturation
Abstract
Under large disturbances, P-f droop-controlled voltage source converters may lose synchronous stability, just like synchronous generator. Moreover, the current limitation leads to a more complicated instability mechanism and decreases stability margin greatly. This letter describes a virtual power angle instability problem and analyzes its mechanism from the virtual power angle characteristic curves of a converter with respect to an infinite bus. Simulation verifies the rationality of the analysis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Control of Power Converters in AC Microgrids
Rocabert, J., Luna, A., Blaabjerg, F., & Rodríguez, P. (2012) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2012.2199334 · Cited by 3,723
Defining Control Strategies for MicroGrids Islanded Operation
Lopes, J. A. P., Moreira, C. L., & Madureira, A. G. (2006) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2006.873018 · Cited by 2,312
Synchronization and power sharing for droop-controlled inverters in islanded microgrids
Simpson-Porco, J. W., Dörfler, F., & Bullo, F. (2013) · Automatica · doi:10.1016/j.automatica.2013.05.018 · Cited by 832
Equivalence of Virtual Synchronous Machines and Frequency-Droops for Converter-Based MicroGrids
D’Arco, S., & Suul, J. A. (2014) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2013.2288000 · Cited by 674
Cited by
Frequency Stability of Synchronous Machines and Grid-Forming Power Converters
Tayyebi, A., Gross, D., Anta, A., Kupzog, F., & Dorfler, F. (2020) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2020.2966524 · Cited by 442
A Review of Current-Limiting Control of Grid-Forming Inverters Under Symmetrical Disturbances
Fan, B., Liu, T., Zhao, F., Wu, H., & Wang, X. (2022) · IEEE Open Journal of Power Electronics · doi:10.1109/ojpel.2022.3227507 · Cited by 371
Fault Recovery Analysis of Grid-Forming Inverters With Priority-Based Current Limiters
Fan, B., & Wang, X. (2023) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2022.3221209 · Cited by 131
Huang, L., Wu, C., Zhou, D., & Blaabjerg, F. (2023) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2022.3199906 · Cited by 107
Self-citationWu, X., Wu, S., Wang, F., Wei, C., Li, R., Jiang, X., & Cai, X. (2025) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2024.3510361 · Cited by 24
Metadata
- Authors
- Xin, H., Huang, L., Zhang, L., Wang, Z., & Hu, J.
- Venue
- IEEE Transactions on Power Systems
- Published
- 2016-11
- Volume
- 31
- Issue
- 6
- Pages
- 5206-5207
- ISSN
- 0885-8950 (ISSN-L)
- 1558-0679
- OpenAlex
- W2344894939
- Cited by
- 299
- References
- 4
- FWCI
- 18.24
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Synchronous Instability Mechanism of P-f Droop-Controlled Voltage Source Converter Caused by Current Saturation. https://app.cochat.ai/papers/10.1109/tpwrs.2016.2521325
- The paper
- Xin, H., Huang, L., Zhang, L., Wang, Z., & Hu, J. (2016). Synchronous Instability Mechanism of P-f Droop-Controlled Voltage Source Converter Caused by Current Saturation. IEEE Transactions on Power Systems. https://doi.org/10.1109/tpwrs.2016.2521325
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.