Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 299

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Synchronous Instability Mechanism of P-f Droop-Controlled Voltage Source Converter Caused by Current Saturation

Xin, Huanhai, Huang, Linbin, Zhang, Leiqi, Wang, Zhen, Hu, Jiabing·2016·IEEE Transactions on Power Systems

Abstract

Under large disturbances, P-f droop-controlled voltage source converters may lose synchronous stability, just like synchronous generator. Moreover, the current limitation leads to a more complicated instability mechanism and decreases stability margin greatly. This letter describes a virtual power angle instability problem and analyzes its mechanism from the virtual power angle characteristic curves of a converter with respect to an infinite bus. Simulation verifies the rationality of the analysis.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tpwrs.2016.2521325

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

See all 299

Metadata

Authors
Xin, H., Huang, L., Zhang, L., Wang, Z., & Hu, J.
Venue
IEEE Transactions on Power Systems
Published
2016-11
Volume
31
Issue
6
Pages
5206-5207
ISSN
  • 0885-8950 (ISSN-L)
  • 1558-0679
OpenAlex
W2344894939
Cited by
299
References
4
FWCI
18.24
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Synchronous Instability Mechanism of P-f Droop-Controlled Voltage Source Converter Caused by Current Saturation. https://app.cochat.ai/papers/10.1109/tpwrs.2016.2521325
The paper
Xin, H., Huang, L., Zhang, L., Wang, Z., & Hu, J. (2016). Synchronous Instability Mechanism of P-f Droop-Controlled Voltage Source Converter Caused by Current Saturation. IEEE Transactions on Power Systems. https://doi.org/10.1109/tpwrs.2016.2521325

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.