The DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.
Intelligent Time-Adaptive Transient Stability Assessment System
Abstract
Online identification of postcontingency transient stability is essential in power system control, as it facilitates the grid operator to decide and coordinate system failure correction control actions. Utilizing machine learning methods with synchrophasor measurements for transient stability assessment has received much attention recently with the gradual deployment of wide-area protection and control systems. In this paper, we develop a transient stability assessment system based on the long short-term memory network. By proposing a temporal self-adaptive scheme, our proposed system aims to balance the trade-off between assessment accuracy and response time, both of which may be crucial in real-world scenarios. Compared with previous work, the most significant enhancement is that our system learns from the temporal data dependencies of the input data, which contributes to better assessment accuracy. In addition, the model structure of our system is relatively less complex, speeding up the model training process. Case studies on three power systems demonstrate the efficacy of the proposed transient stability as sessment system.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hochreiter, S., & Schmidhuber, J. (1997) · Neural Computation · doi:10.1162/neco.1997.9.8.1735 · Cited by 102,318
Adam: A Method for Stochastic Optimization
Kingma, D. P., & Ba, J. (2014) · arXiv · doi:10.48550/arxiv.1412.6980 · Cited by 98,946
LeCun, Y., Bengio, Y., & Hinton, G. (2015) · Nature · doi:10.1038/nature14539 · Cited by 84,126
Power System Stability and Control
Kundur, P. (1994) · Cited by 19,639
Learning long-term dependencies with gradient descent is difficult
Bengio, Y., Simard, P., & Frasconi, P. (1994) · IEEE Transactions on Neural Networks · doi:10.1109/72.279181 · Cited by 8,542
Identification and control of dynamical systems using neural networks
Narendra, K. S., & Parthasarathy, K. (1990) · IEEE Transactions on Neural Networks · doi:10.1109/72.80202 · Cited by 8,014
Hansen, L. K., & Salamon, P. (1990) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/34.58871 · Cited by 4,260
(2004) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2004.825981 · Cited by 3,719
Devijver, P. A., & Kittler, J. (1982) · Prentice-Hall International eBooks · Cited by 2,910
Energy Function Analysis for Power System Stability
Pai, M. A. (1989) · Springer eBooks · doi:10.1007/978-1-4613-1635-0 · Cited by 1,991
Gomez, F. R., Rajapakse, A. D., Annakkage, U. D., & Fernando, I. T. (2011) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2010.2082575 · Cited by 407
IEEE Standard for Synchrophasor Data Transfer for Power Systems
(2011) · doi:10.1109/ieeestd.2011.6111222 · Cited by 349
Automatic Learning Techniques in Power Systems
Wehenkel, L. A. (1998) · Springer eBooks · doi:10.1007/978-1-4615-5451-6 · Cited by 318
Online dynamic security assessment with missing pmu measurements: A data mining approach
He, M., Vittal, V., & Zhang, J. (2013) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2013.2246822 · Cited by 188
Rotor Angle Instability Prediction Using Post-Disturbance Voltage Trajectories
Rajapakse, A. D., Gomez, F., Nanayakkara, K., Crossley, P. A., & Terzija, V. V. (2010) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2009.2036265 · Cited by 184
Zhang, R., Xu, Y., Dong, Z. Y., & Wong, K. P. (2015) · IET Generation, Transmission & Distribution · doi:10.1049/iet-gtd.2014.0264 · Cited by 163
An artificial intelligence framework for online transient stability assessment of power systems
Wehenkel, L. A., Cutsem, T. V., & Ribbens-Pavella, M. (1989) · IEEE Transactions on Power Systems · doi:10.1109/59.193853 · Cited by 136
Time Series Shapelet Classification Based Online Short-Term Voltage Stability Assessment
Zhu, L., Lü, C., & Sun, Y. (2015) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2015.2413895 · Cited by 125
Application of Energy-Based Power System Features for Dynamic Security Assessment
Geeganage, J., Annakkage, U. D., Weekes, T., et al. (2014) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2014.2353048 · Cited by 114
Kamwa, I., Samantaray, S. R., & Joós, G. (2011) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2011.2164948 · Cited by 101
Cited by
Foundations and Challenges of Low-Inertia Systems (Invited Paper)
Milano, F., Dörfler, F., Hug, G., Hill, D. J., & Verbič, G. (2018) · 2018 Power Systems Computation Conference (PSCC) · doi:10.23919/pscc.2018.8450880 · Cited by 1,039
Self-citationIntelligent Fault Detection Scheme for Microgrids With Wavelet-Based Deep Neural Networks
Yu, J. J. Q., Hou, Y., Lam, A. Y. S., & Li, V. O. K. (2019) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2017.2776310 · Cited by 451
Self-citationOnline False Data Injection Attack Detection With Wavelet Transform and Deep Neural Networks
Yu, J. J. Q., Hou, Y., & Li, V. O. K. (2018) · IEEE Transactions on Industrial Informatics · doi:10.1109/tii.2018.2825243 · Cited by 378
Self-citationA Review of Machine Learning Approaches to Power System Security and Stability
Alimi, O. A., Ouahada, K., & Abu-Mahfouz, A. M. (2020) · IEEE Access · doi:10.1109/access.2020.3003568 · Cited by 377
Artificial Intelligence Techniques in Smart Grid: A Survey
Omitaomu, O. A., & Niu, H. (2021) · Smart Cities · doi:10.3390/smartcities4020029 · Cited by 371
Metadata
- Authors
- Yu, J. J. Q., Hill, D. J., Lam, A. Y. S., Gu, J., & Li, V. O. K.
- Venue
- IEEE Transactions on Power Systems
- Published
- 2018-01
- Volume
- 33
- Issue
- 1
- Pages
- 1049-1058
- ISSN
- 0885-8950 (ISSN-L)
- 1558-0679
- OpenAlex
- W2540406226
- Cited by
- 370
- References
- 20
- FWCI
- 11.64
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.