Attack Detection and Identification for Automatic Generation Control Systems
The DOI matches its Crossref record; 36 of the 37 references it cites were found in a registry or an index.
Abstract
Integrating today's power systems with communication infrastructure makes them vulnerable to cyber-attacks, which can disrupt their normal operation undetectable. Automatic generation control (AGC) is one of the vulnerable controllers in power grids, since it greatly depends on communication systems. This paper first shows that false data injection attacks (FDIAs) against an AGC system can be carried out stealthily with destructive outcomes. Then, it proposes an anomaly based attack detection and identification method for protecting the AGC system against cyber vulnerabilities. To detect attacks, the proposed method estimates the load frequency control system's states using an unknown input observer (UIO), and calculates the UIO's residual function. A discrepancy between the residual functions and a predefined threshold signifies an FDIA. Different identification UIOs are then used to determine the attack type, i.e., which system parameter(s) is (are) targeted by the attack. The effectiveness of the proposed method is corroborated using simulation results for a three-area power system and the IEEE 39-bus network.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“This control system—if attacked by FDIA—will lead to overloading transmission lines by excessive power generation [56].”
From Impact, Vulnerabilities, and Mitigation Strategies for Cyber-Secure Critical Infrastructure. (2023) · cites this paper as [56]
Citations
Cites
Power System Stability and Control
Kundur, P. (1994) · Cited by 19,639
Power Generation, Operation, and Control
Wood, A. J., & Wollenberg, B. F. (1984) · Cited by 8,303
The algebraic eigenvalue problem
Wilkinson, J. H. (1965) · Cited by 5,833
Linear System Theory and Design
Chen, C. (1995) · Medical Entomology and Zoology · Cited by 3,093
Energy Function Analysis for Power System Stability
Pai, M. A. (1989) · Springer eBooks · doi:10.1007/978-1-4613-1635-0 · Cited by 1,991
(2005) · Nonconvex Optimization and Its Applications · doi:10.1007/0-387-28154-1_8 · Cited by 1,550 · cited 2×
“To make the obtained model suitable for numerical implementation, (30) and (33) must be discretized [26].”
BackgroundHill, P. G. (1977) · Cited by 1,394
尾形, 克. (1995) · Prentice-Hall International eBooks · Cited by 1,137
Cyber security in the Smart Grid: Survey and challenges
Wang, W., & Lu, Z. (2013) · Computer Networks · doi:10.1016/j.comnet.2012.12.017 · Cited by 1,123
Robust pole assignment in linear state feedback
KAUTSKY, J., NICHOLS, N. K., & VAN DOOREN, P. (1985) · International Journal of Control · doi:10.1080/0020718508961188 · Cited by 1,076
Research works printed but not linked: 3
- 2016, Compact Load-Shedding Relay PML630 Series—Technical Manual
- clarke, 2004, Practical Modern SCADA Protocols DNP3 60870 5 and Related Systems
- 0, 700G Series—Generator Protection Technical Manual
Cited by
Yohanandhan, R. V., Elavarasan, R. M., Manoharan, P., & Mihet-Popa, L. (2020) · IEEE Access · doi:10.1109/access.2020.3016826 · Cited by 391
Karimipour, H., Dehghantanha, A., Parizi, R. M., Choo, K.-K. R., & Leung, H. (2019) · IEEE Access · doi:10.1109/access.2019.2920326 · Cited by 355
“Online and continuous system monitoring is a requirement to detect targeted cyber-attacks and achieve attack resilience [7].”
BackgroundA survey on attack detection, estimation and control of industrial cyber–physical systems
Zhang, D., Wang, Q.-G., Feng, G., Shi, Y., & Vasilakos, A. V. (2021) · ISA Transactions · doi:10.1016/j.isatra.2021.01.036 · Cited by 317
Du, D., Zhu, M., Li, X., Fei, M., Bu, S., Wu, L., & Li, K. (2023) · Journal of Modern Power Systems and Clean Energy · doi:10.35833/mpce.2021.000604 · Cited by 175
Joint Detection and Mitigation of False Data Injection Attacks in AGC Systems
Khalaf, M., Youssef, A., & El-Saadany, E. (2019) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2018.2872120 · Cited by 160
Self-citationImpact, Vulnerabilities, and Mitigation Strategies for Cyber-Secure Critical Infrastructure.
Riggs, H., Tufail, S., Parvez, I., Tariq, M., Khan, M. A., Amir, A., Vuda, K. V., & Sarwat, A. I. (2023) · Sensors · doi:10.3390/s23084060 · Cited by 124
“This control system—if attacked by FDIA—will lead to overloading transmission lines by excessive power generation [56].”
BackgroundVahidi, S., Ghafouri, M., Au, M., Kassouf, M., Mohammadi, A., & Debbabi, M. (2023) · IEEE Communications Surveys & Tutorials · doi:10.1109/comst.2023.3251899 · Cited by 149
Tuyen, N. D., Quan, N. S., Linh, V. B., Vu, T., & Fujita, G. (2022) · IEEE Access · doi:10.1109/access.2022.3163551 · Cited by 148
Data-Driven Resilient Automatic Generation Control Against False Data Injection Attacks
Chen, C., Chen, Y., Zhao, J., Zhang, K., Ni, M., & Ren, B. (2021) · IEEE Transactions on Industrial Informatics · doi:10.1109/tii.2021.3058413 · Cited by 122
Survey of false data injection in smart power grid: Attacks, countermeasures and challenges
Aoufi, S., Derhab, A., & Guerroumi, M. (2020) · Journal of Information Security and Applications · doi:10.1016/j.jisa.2020.102518 · Cited by 138
Resilient Frequency Control Design for Microgrids Under False Data Injection
Khalghani, M. R., Solanki, J. M., Solanki, S. K., Khooban, M. H., & Sargolzaei, A. (2020) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2020.2975494 · Cited by 105
“[27], [28] proposed model-based estimation and detection of unknown input and do not address controlling and thwarting of the disruptions.”
BackgroundWang, X., Luo, X., Zhang, Y., & Guan, X. (2019) · IEEE Internet of Things Journal · doi:10.1109/jiot.2019.2916670 · Cited by 98
“, A and C are taken in [38], and the false attack sequence is as the same as [37].”
BackgroundFalse Data Injection Attack and Defense Method on Load Frequency Control
Li, Y., Huang, R., & Ma, L. (2020) · IEEE Internet of Things Journal · doi:10.1109/jiot.2020.3021429 · Cited by 89
“Presently, there are many studies on FDIA, and its detection is closely related to the state estimation in the smart grid [11], [14], [17].”
BackgroundMethodCoordinated control scheme for provision of frequency regulation service by virtual power plants
Oshnoei, A., Kheradmandi, M., Blaabjerg, F., Hatziargyriou, N. D., Muyeen, S. M., & Anvari‐Moghaddam, A. (2022) · Applied Energy · doi:10.1016/j.apenergy.2022.119734 · Cited by 83
Detection and Mitigation of Cyber-Attacks on AGC Systems of Low Inertia Power Grid
Roy, S. D., & Debbarma, S. (2019) · IEEE Systems Journal · doi:10.1109/jsyst.2019.2943921 · Cited by 90
“Since the attacker’s motive is to maintain stealthiness in such a way that the attack remains undetected at the control center, following conditions are considered to design the attack [3], [11]: 1) The frequency deviation signal received by the control center should be below |0.1| Hz.”
BackgroundInfluentialA Two-stage Kalman Filter for Cyber-attack Detection in Automatic Generation Control System
Tummala, A. S. L. V., & Inapakurthi, R. K. (2022) · Journal of Modern Power Systems and Clean Energy · doi:10.35833/mpce.2019.000119 · Cited by 80
Luo, X., Li, Y., Wang, X., & Guan, X. (2020) · IEEE Internet of Things Journal · doi:10.1109/jiot.2020.3005926 · Cited by 79
Mohammadikia, R., & Aliasghary, M. (2018) · International Transactions on Electrical Energy Systems · doi:10.1002/etep.2735 · Cited by 76
Cyber resilience in renewable microgrids: A review of standards, challenges, and solutions
Rouhani, S. H., Su, C., Mobayen, S., Razmjooy, N., & Elsisi, M. (2024) · Energy · doi:10.1016/j.energy.2024.133081 · Cited by 89
Wang, X., Luo, X., Zhang, M., Jiang, Z., & Guan, X. (2020) · IEEE Internet of Things Journal · doi:10.1109/jiot.2020.2966221 · Cited by 83
“, A and C are taken in [38], and the false attack sequence is as the same as [37].”
BackgroundXiahou, K., Liu, Y., & Wu, Q. (2021) · IEEE Journal of Emerging and Selected Topics in Industrial Electronics · doi:10.1109/jestie.2021.3112919 · Cited by 75
An Intrusion Detection Method for Line Current Differential Relays
Ameli, A., Hooshyar, A., El-Saadany, E. F., & Youssef, A. (2019) · IEEE Transactions on Information Forensics and Security · doi:10.1109/tifs.2019.2916331 · Cited by 66
“A UIO estimating Xs at time step k+1 is formulated as [44]:”
MethodSelf-citationCAE: Contextual auto-encoder for multivariate time-series anomaly detection in air transportation
Chevrot, A., Vernotte, A., & Legeard, B. (2022) · Computers & Security · doi:10.1016/j.cose.2022.102652 · Cited by 74
Lu, A., & Yang, G. (2022) · IEEE Transactions on Automatic Control · doi:10.1109/tac.2022.3218545 · Cited by 72
Command Authentication Using Multiagent System for Attacks on the Economic Dispatch Problem
Siu, J. Y., Kumar, N., & Panda, S. K. (2022) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2022.3172240 · Cited by 60
False Data Injection Attack Detection in Smart Grid Using Energy Consumption Forecasting
Mahi-al-rashid, A., Hossain, F., Anwar, A., & Azam, S. (2022) · Energies · doi:10.3390/en15134877 · Cited by 79
Naeem, H., Ullah, F., & Srivastava, G. (2024) · Expert Systems · doi:10.1111/exsy.13556 · Cited by 61
“Continuous system monitoring may strengthen defence against cyber-physical attacks (Ameli et al., 2018).”
Intelligent Anomaly Detection for Large-scale Smart Grids
Karimipour, H., Geris, S., Dehghantanha, A., & Leung, H. (2019) · Conference proceedings - Canadian Conference on Electrical and Computer Engineering · doi:10.1109/ccece.2019.8861995 · Cited by 58
Qu, Z., Younis, W., Liu, X., Junejo, A. K., Almutairi, S. Z., & Wang, P. (2024) · IEEE Access · doi:10.1109/access.2024.3445165 · Cited by 58
Stable Adaptation in Multi-Area Load Frequency Control Under Dynamically-Changing Topologies
Tao, T., Roy, S., & Baldi, S. (2020) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2020.3044436 · Cited by 56
“The dynamics of a single-area power system can be described as [7]–[13]:”
BackgroundMethodInfluentialSyrmakesis, A. D., Alhelou, H. H., & Hatziargyriou, N. D. (2023) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2023.3242015 · Cited by 55
“For instance, an unknown input observer has been utilised in [13], [14] for attack detection and identification.”
MethodWang, X., Luo, X., Zhang, M., & Guan, X. (2019) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2019.03.008 · Cited by 57
Raj, T. D., Kumar, C., Kotsampopoulos, P. C., & Fayek, H. H. (2023) · Energies · doi:10.3390/en16042014 · Cited by 51
COVID-19, Green Deal and recovery plan permanently change emissions and prices in EU ETS Phase IV
Bruninx, K., & Ovaere, M. (2022) · Nature Communications · doi:10.1038/s41467-022-28398-2 · Cited by 50
“An unknown input observer is used to identify cyber attacks against LFC [30].”
MethodA Comprehensive Review of Load Frequency Control Technologies
Rasolomampionona, D., Połecki, M., Zagrajek, K., Wróblewski, W., & Januszewski, M. (2024) · Energies · doi:10.3390/en17122915 · Cited by 50
False Data Injection Attacks Against Synchronization Systems in Microgrids
Mohamed, A. S., Arani, M. F. M., Jahromi, A. A., & Kundur, D. (2021) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2021.3080693 · Cited by 57
“Yet, most of the literature on the cybersecurity of generation control loops has been focused on automatic generation control (AGC) [7]–[9].”
BackgroundResilient Adaptive Wide-Area Damping Control to Mitigate False Data Injection Attacks
Zhao, Y., Yao, W., Nan, J., Fang, J., Ai, X., Wen, J., & Cheng, S. (2020) · IEEE Systems Journal · doi:10.1109/jsyst.2020.3020425 · Cited by 48
From Static to Dynamic Anomaly Detection With Application to Power System Cyber Security
Pan, K., Pálenský, P., & Esfahani, P. M. (2019) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2019.2943304 · Cited by 56
“Recently, a variant of observer-based methods is also investigated in [20] so as to deal with unknown natural exogenous inputs.”
BackgroundPanthi, M., & Das, T. K. (2022) · International Journal of Critical Infrastructure Protection · doi:10.1016/j.ijcip.2022.100567 · Cited by 52
Pan, K., Rakhshani, E., & Pálenský, P. (2020) · IEEE Access · doi:10.1109/access.2020.3013889 · Cited by 46
Roy, S. D., Debbarma, S., & Guerrero, J. M. (2022) · IEEE Journal on Emerging and Selected Topics in Circuits and Systems · doi:10.1109/jetcas.2022.3142055 · Cited by 43
Optimal False Data Injection Attacks Against Power System Frequency Stability
Jafari, M., Rahman, M. A., & Paudyal, S. (2022) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2022.3206717 · Cited by 51
“We use the IEEE 39-bus system [29] shown in Fig.”
BackgroundMethodInfluentialAyad, A., Khalaf, M., Salama, M. M. A., & El-Saadany, E. F. (2022) · Electric Power Systems Research · doi:10.1016/j.epsr.2022.107958 · Cited by 43
Self-citationVidyarthi, P. K., Kumar, A., & Raj, S. (2024) · Chaos Solitons & Fractals · doi:10.1016/j.chaos.2024.115542 · Cited by 42
Hierarchical-Attention-Based Defense Method for Load Frequency Control System Against DoS Attack
Li, Y., Huang, R., & Ma, L. (2021) · IEEE Internet of Things Journal · doi:10.1109/jiot.2021.3073060 · Cited by 42
Zhao, X., Ma, Z., Shi, X., & Zou, S. (2024) · IEEE Transactions on Industrial Informatics · doi:10.1109/tii.2024.3390549 · Cited by 40
“In order to avoid the impractical requirement on real-time load change, the authors in [19] and [20] developed the delayed unknown input observer (UIO) to estimate the system state by collecting delayed output information of the LFC system, and then, the attack can be detected by monitoring the…”
BackgroundMethodA novel OC-SVM based ensemble learning framework for attack detection in AGC loop of power systems
Roy, S. D., & Debbarma, S. (2021) · Electric Power Systems Research · doi:10.1016/j.epsr.2021.107625 · Cited by 47
Attack Detection and Isolation for Distributed Load Shedding Algorithm in Microgrid Systems
Yan, J., Guo, F., & Wen, C. (2020) · IEEE Journal of Emerging and Selected Topics in Industrial Electronics · doi:10.1109/jestie.2020.3004744 · Cited by 38
“According to [25], the frequency of the MG will be synchronized as”
BackgroundSah, S. V., Prakash, V., Pathak, P. K., & Yadav, A. K. (2024) · Chaos Solitons & Fractals · doi:10.1016/j.chaos.2024.115578 · Cited by 41
Coordinated False Data Injection Attacks in AGC System and Its Countermeasure
He, X., Liu, X., & Li, P. (2020) · IEEE Access · doi:10.1109/access.2020.3033566 · Cited by 44
“An alarm will raise if any of the following situations happens : The Rate of Change of Frequency (RoCoF) exceeds a certain value, e.g., if the frequency exceeds 1Hz during a 15-second time window, an alarm will be raised [20].”
BackgroundMethodA Reinforcement Learning Approach to Undetectable Attacks Against Automatic Generation Control
Shereen, E., Kazari, K., & Dán, G. (2023) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2023.3288676 · Cited by 38
“Simple FDIAs such as ramp , pulse , step , scaling , sine , random , and replay attacks [9], [10], [14], [17], [19], [23], [27], [28], [31] have been commonly utilized either (1) to quantify the impact of FDIAs on AGC systems, or (2) to evaluate FDIA detection approaches.”
BackgroundMethodInfluentialAdvanced Persistent Threat Detection and Mitigation Using Machine Learning Model
Sakthivelu, U., & Kumar, C. N. S. V. (2023) · Intelligent Automation & Soft Computing · doi:10.32604/iasc.2023.036946 · Cited by 34
“Due to the high complexity and limitations of gradient spread and network layers, real-time APT attacks are often dealt with better by deep neural networks than neural networks in APT attack identification by Ameli et al. [10].”
BackgroundVidyarthi, P. K., & Kumar, A. (2023) · Optimal Control Applications and Methods · doi:10.1002/oca.3052 · Cited by 34
Cyberattack-Resilient Secondary Frequency Control Scheme for Stand-Alone Microgrids
Aluko, A., Musumpuka, R., & Dorrell, D. G. (2022) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2022.3159965 · Cited by 41
“Another salient design consideration for stealthy SSFD-basedattackisthepermissiblerateofchangeoffrequency deviationasspecifiedbytheMGstandardtoensurethatthe compromised measurement does not bypass the observer [18].”
BackgroundInfluentialSurvey of Load-Altering Attacks Against Power Grids: Attack Impact, Detection, and Mitigation
Maleki, S., Pan, S., Lakshminarayana, S., & Konstantinou, C. (2025) · IEEE Open Access Journal of Power and Energy · doi:10.1109/oajpe.2025.3562052 · Cited by 47
“…have been proposed, such as strategic protection of sensors to prevent undetectable attacks [14], machine learning (ML)- based approaches to detect cyberattacks [11], and moving target defense to invalidate attacker’s knowledge of the target system and thus making the attacks detectable [15].”
Mitigating Sensor Attacks Against Industrial Control Systems
Cómbita, L. F., Cárdenas, Á. A., & Quijano, N. (2019) · IEEE Access · doi:10.1109/access.2019.2927484 · Cited by 36
“It is important to mention that fault-tolerant control (FTC) technology is being used as a tool for dealing with cyber-attacks [16], [17]; however, even these works that leverage the fault-tolerant literature focus on detection and isolation, mainly using unknown input observers (UIOs), they do not…”
MethodA Decentralized Intrusion Detection System for Security of Generation Control
Roy, S. D., Debbarma, S., & Iqbal, A. (2022) · IEEE Internet of Things Journal · doi:10.1109/jiot.2022.3163502 · Cited by 32
“Table I, the attackers may plan sophisticated stealthy attacks to harm the system integrity while being undetectable by the traditional security algorithms [9].”
BackgroundMethodAluko, A., Carpanen, R. P., Dorrell, D. G., & Ojo, E. E. (2020) · IEEE Systems Journal · doi:10.1109/jsyst.2020.3005979 · Cited by 31
Syrmakesis, A. D., Alhelou, H. H., & Hatziargyriou, N. D. (2023) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2023.3332702 · Cited by 33
“The physical part of LFC interacts with the cyber layer via industrial network protocols, including DNP3 [8] and ICCP [9].”
BackgroundChaudhary, A. K., Roy, S., Guha, D., Negi, R., & Banerjee, S. (2024) · Energy · doi:10.1016/j.energy.2024.131809 · Cited by 30
Shangguan, X., Yu, M.-H., Zhang, C., & He, Y. M. (2025) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2025.3578985 · Cited by 30
“These methods include robust con-trol defense, state estimation, sparse optimization techniques, matrix separation, and observer-based detection methods [1], [9], [10], [11], [12], [13], [14], [15].”
Huang, R., Li, Y., & Wang, X. (2022) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2022.108815 · Cited by 37
Cyber-attack-tolerant Frequency Control of Power Systems
Chen, C., Zhang, K., Ni, M., & Wang, Y. (2021) · Journal of Modern Power Systems and Clean Energy · doi:10.35833/mpce.2019.000185 · Cited by 29
Stability Assessment of Secondary Frequency Control System With Dynamic False Data Injection Attacks
Chen, C., Zhang, X., Cui, M., Zhang, K., Zhao, J., & Li, F. F. (2021) · IEEE Transactions on Industrial Informatics · doi:10.1109/tii.2021.3107539 · Cited by 29
Zhu, F., Zhou, X., Zhang, Y., Xu, D., & Fu, J. (2021) · Energy Reports · doi:10.1016/j.egyr.2021.09.029 · Cited by 28
Oshnoei, A., Sadeghian, O., & Anvari‐Moghaddam, A. (2022) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2022.3218589 · Cited by 28
Ahmadian, S., Tang, X., Malki, H., & Han, Z. (2019) · IEEE Access · doi:10.1109/access.2019.2899293 · Cited by 33
“In [6], FDI attacks to AGC are detected using load frequency control system of generators.”
MethodKaviani, R., & Hedman, K. W. (2021) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2021.3135357 · Cited by 27
“The authors in [13], [14] falsified the control signals to attack the systems’ stability.”
BackgroundRanjan, M., Shankar, R., Raj, U., Kumar, S., & Kumar, J. (2024) · Optimal Control Applications and Methods · doi:10.1002/oca.3184 · Cited by 25
“11 In the detection of optimal attack schemes, a threshold-based detection method is employed.”
APT attack detection algorithm based on spatio-temporal association analysis in industrial network
Wang, X., Liu, Q., Pan, Z., & Pang, G. (2020) · Journal of Ambient Intelligence and Humanized Computing · doi:10.1007/s12652-020-01840-3 · Cited by 25
Intrusion Detection Method Based on SMOTE Transformation for Smart Grid Cybersecurity
Massaoudi, M., Refaat, S. S., & Abu‐Rub, H. (2022) · International Conference on Smart Grid and Renewable Energy (SGRE) · doi:10.1109/sgre53517.2022.9774070 · Cited by 31
Research on Cyber Attacks and Defensive Measures of Power Communication Network
Wu, Y., Ru, Y., Lin, Z., Liu, C., Xue, T., Zhao, X., & Chen, J. (2022) · IEEE Internet of Things Journal · doi:10.1109/jiot.2022.3181698 · Cited by 30
Event‐triggered detection of cyberattacks on load frequency control
Patel, A., & Purwar, S. (2020) · IET Cyber-Physical Systems Theory & Applications · doi:10.1049/iet-cps.2019.0067 · Cited by 27
Beura, S., & Padhy, B. P. (2022) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2022.3224996 · Cited by 29
“The bad data injection (BDI) algorithm [15] is formulated”
MethodSyrmakesis, A. D., Alhelou, H. H., & Hatziargyriou, N. D. (2023) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2023.3340744 · Cited by 24
“The communication of the physical system with its cyber layer is achieved through industrial network protocols, such as Distributed Network Protocol version 3.0 (DNP3) [6], a Inter-Control Center Communication Protocol (ICCP) [7], etc.”
InfluentialYameen, M. Z., Junejo, A. K., Lu, Z., Siddiqui, R. A., El-Sousy, F. F. M., & Naveed, I. (2025) · Scientific Reports · doi:10.1038/s41598-025-01481-6 · Cited by 23
Real-Time Cyber Attack Detection Scheme for Standalone Microgrids
Aluko, A., Carpanen, R. P., Dorrell, D. G., & Ojo, E. E. (2022) · IEEE Internet of Things Journal · doi:10.1109/jiot.2022.3180939 · Cited by 29
“In contrast to [24] and [36], the real-time detection accuracy of the proposed UIO scheme is evaluated using two metrics.”
MethodSadi, M. A. H., Zhao, D., Hong, T., & Ali, M. H. (2022) · IEEE Systems Journal · doi:10.1109/jsyst.2022.3186619 · Cited by 27
“We also compared the performance of the proposed time sequence machine learning-based anomaly detection method with a time sequence clustering-based anomaly detection method at each sampling time [10].”
ResultResilient Identification of Distribution Network Topology
Jafarian, M. J., Soroudi, A., & Keane, A. (2020) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2020.3037639 · Cited by 24
“Securing the power system management against cyber-attacks has been the subject of many recent studies, like [16] and [17].”
BackgroundRouhani, S. H., Mojallali, H., & Baghramian, A. (2021) · International Transactions on Electrical Energy Systems · doi:10.1002/2050-7038.13206 · Cited by 22
Wu, D., Guo, F., Yao, Z., Zhu, D., Zhang, Z., Li, L., Du, X., & Zhang, J. (2024) · Applied Sciences · doi:10.3390/app14198631 · Cited by 25
“They require the careful management of load and generation imbalances across different regions to maintain optimal performance [16–20].”
Optimal False Data Injection Attack Against Load-Frequency Control in Power Systems
Jafari, M., Rahman, M. A., & Paudyal, S. (2023) · IEEE Transactions on Information Forensics and Security · doi:10.1109/tifs.2023.3305868 · Cited by 30
“The authors in [11] and [32] aim at finding the optimal attack within a minimum amount of time.”
BackgroundRoy, S. D., Debbarma, S., & Guerrero, J. M. (2022) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2022.108409 · Cited by 23
Du, D., Zhu, M., Wu, D., Li, X., Fei, M., Hu, Y., & Li, K. (2023) · Applied Energy · doi:10.1016/j.apenergy.2023.122001 · Cited by 21
“Using statistical information received, some attack detection methods have been proposed [51, 52, 53].”
Deep Learning for Smart Grid Intrusion Detection: A Hybrid CNN-LSTM-Based Model
Alsaiari, A., & Ilyas, M. (2024) · International Journal of Artificial Intelligence & Applications · doi:10.5121/ijaia.2024.15301 · Cited by 24
Hu, Z., Liu, S., Luo, W., & Wu, L. (2020) · IET Generation Transmission & Distribution · doi:10.1049/iet-gtd.2020.0389 · Cited by 20
Aluko, A., Carpanen, R. P., Dorrell, D. G., & Ojo, E. E. (2020) · IEEE PES/IAS PowerAfrica Conference (PowerAfrica) · doi:10.1109/powerafrica49420.2020.9219790 · Cited by 20
“The automatic generation control (AGC) or load frequency control (LFC) is a communication-reliant system that is highly susceptible to cyber attacks [11].”
BackgroundRouhani, S. H., Mojallali, H., & Baghramian, A. (2022) · Transactions of the Institute of Measurement and Control · doi:10.1177/01423312211068645 · Cited by 19
“…and Iqbal, 2015), denying of service (Liu et al., 2013; Shen et al., 2019), or replacing the corrected data with false data (Abbaspour et al., 2017; Ameli et al., 2018; Chen et al., 2018; Huang et al., 2018; Khalaf et al. 2019; Law et al., 2015; Mohajerin Esfahani et al., 2010; Sargolzaei et al.,…”
BackgroundMethodKong, X., Lu, Z., Li, Y., Guo, X., Zhang, J., & Ding, S. (2024) · Applied Energy · doi:10.1016/j.apenergy.2024.124785 · Cited by 22
Padhy, S. K., Sahu, P. R., Khadanga, R. K., Arya, Y., & Panda, S. (2025) · Electric Power Systems Research · doi:10.1016/j.epsr.2025.111736 · Cited by 18
Robust Load Frequency Control in Cyber-Vulnerable Smart Grids with Renewable Integration
Singh, R., Kumar, R., Raj, U., & Shankar, R. (2025) · Energies · doi:10.3390/en18112899 · Cited by 18
SMS–A Security Management System for Steam Turbines Using a Multisensor Array
Kordestani, M., Chaibakhsh, A., & Saif, M. (2020) · IEEE Systems Journal · doi:10.1109/jsyst.2019.2960149 · Cited by 18
“Themodel-basedmethodsincludeawiderangeof approaches,suchasKalmanfilter(KF)[14],particlefilter(PF) [15],andobserver-basedmethod[16].”
Ameli, A., Ghafouri, M., Salama, M. M. A., & El-Saadany, E. F. (2022) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2022.3142040 · Cited by 18
“2) UIO Stability: A UIO is stable when its poles, or the eigenvalues of E, all lie in the unit circle of the complex plane [28], [30].”
BackgroundMethodSelf-citationAbazari, A., Soleymani, M. M., Zadsar, M., Ghafouri, M., Assi, C. M., & Shafie‐khah, M. (2023) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2023.3304537 · Cited by 20
“Generally speaking, many previous papers have focused on the behaviours of state variables and used model-based or alternatively utilized learning-based approaches to identify the type of cyber attacks which manipulate only measurement and control channels [19], [20], [21].”
BackgroundFang, J. (2024) · Entertainment Computing · doi:10.1016/j.entcom.2024.100779 · Cited by 20
Khalaf, M., Youssef, A., & El-Saadany, E. F. (2018) · IEEE Electrical Power and Energy Conference (EPEC) · doi:10.1109/epec.2018.8598446 · Cited by 17
Self-citationDetection and Location of Bias Load Injection Attack in Smart Grid via Robust Adaptive Observer
Wang, X., Luo, X., Pan, X., & Guan, X. (2020) · IEEE Systems Journal · doi:10.1109/jsyst.2020.2967126 · Cited by 20
“In [26], an anomaly based attack detection and identification method based on the designed unknown input observer.”
MethodBakeer, M., Bakeer, A., Magdy, G., & Aly, M. H. (2023) · Journal of Cleaner Production · doi:10.1016/j.jclepro.2023.138866 · Cited by 20
A Multi-Source Power System’s Load Frequency Control Utilizing Particle Swarm Optimization
Qu, Z., Younis, W., Wang, Y., & Georgievitch, P. M. (2024) · Energies · doi:10.3390/en17020517 · Cited by 16
Detection, Identification, and Mitigation of False Data Injection Attacks in Vehicle Platooning
Ahmed, N., Ameli, A., & Naser, H. (2024) · IEEE Transactions on Vehicular Technology · doi:10.1109/tvt.2024.3456080 · Cited by 22
“As shown in [31], there exists an F that satisfies (42 where 3 n − 1 denotes the size of M vector, and J α − 1 can be found using J α in (36): Equation (44) represents a necessary condition for constructing an accurate UIO for the given system.”
InfluentialSelf-citation
Metadata
- Authors
- Ameli, A., Hooshyar, A., El-Saadany, E. F., & Youssef, A. M.
- Affiliations
- University of Waterloo (CA)
- York University (CA)
- Concordia University (CA)
- Venue
- IEEE Transactions on Power Systems
- Published
- 2018-09
- Volume
- 33
- Issue
- 5
- Pages
- 4760-4774
- ISSN
- 0885-8950 (ISSN-L)
- 1558-0679
- OpenAlex
- W2793107922
- Cited by
- 222
- References
- 37
- Citations by year
- 2026: 11 · 2025: 26 · 2024: 42 · 2023: 33 · 2022: 39 · 2021: 20 · 2020: 33 · 2019: 14 · 2018: 4
- FWCI
- 10.98
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- IEEE Transactions on Power Systems (publishedVersion)
- Funders
- NSERC-DGDND (#2017-00020)
- Topics
- Physical Sciences › Engineering › Control and Systems Engineering › Smart Grid Security and Resilience
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Power System Optimization and Stability
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Frequency Control in Power Systems
- Keywords
- automatic generation control, false data injection attacks, attack detection, load frequency control, unknown input observer, residual generation, power system cybersecurity, state estimation, three-area power system, IEEE 39-bus system
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.