The DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.
Placement and Implementation of Grid-Forming and Grid-Following Virtual Inertia and Fast Frequency Response
Open accessAbstract
The electric power system is witnessing a shift in the technology of generation. Conventional thermal generation based on synchronous machines is gradually being replaced by power electronics interfaced renewable generation. This new mode of generation, however, lacks the natural inertia and governor damping, which are quintessential features of synchronous machines. The loss of these features results in increasing frequency excursions and, ultimately, system instability. Among the numerous studies on mitigating these undesirable effects, the main approach involves virtual inertia (VI) emulation to mimic the behavior of synchronous machines. In this paper, explicit models of grid-following and grid-forming VI devices are developed for inertia emulation and fast frequency response in low-inertia systems. An optimization problem is formulated to optimize the parameters and location of these devices in a power system to increase its resilience. Finally, a case study based on a high-fidelity model of the South-East Australian system is used to illustrate the effectiveness of such devices.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Weiss, M. (1997) · Automatica · doi:10.1016/s0005-1098(97)00132-5 · Cited by 5,495
Mangasarian, O. L. (1994) · Society for Industrial and Applied Mathematics eBooks · doi:10.1137/1.9781611971255 · Cited by 3,220
Synchronverters: Inverters That Mimic Synchronous Generators
Zhong, Q.-C., & Weiss, G. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2048839 · Cited by 3,107
Modeling, Analysis and Testing of Autonomous Operation of an Inverter-Based Microgrid
Pogaku, N., Prodanovic, M., & Green, T. C. (2007) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2006.890003 · Cited by 3,018
Power System Dynamics and Stability
Sauer, P. W., & Pai, M. A. (1997) · Cited by 2,154
Wind Turbines Emulating Inertia and Supporting Primary Frequency Control
Morren, J., de Haan, S. W. H., Kling, W. L., & Ferreira, J. A. (2006) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2005.861956 · Cited by 1,263
A phase tracking system for three phase utility interface inverters
Chung, S.-K. (2000) · IEEE Transactions on Power Electronics · doi:10.1109/63.844502 · Cited by 1,192
Foundations and Challenges of Low-Inertia Systems (Invited Paper)
Milano, F., Dörfler, F., Hug, G., Hill, D. J., & Verbič, G. (2018) · 2018 Power Systems Computation Conference (PSCC) · doi:10.23919/pscc.2018.8450880 · Cited by 1,039
Impact of Low Rotational Inertia on Power System Stability and Operation
Ulbig, A., Borsche, T., & Andersson, G. (2014) · IFAC Proceedings Volumes · doi:10.3182/20140824-6-za-1003.02615 · Cited by 908
Virtual synchronous generators: A survey and new perspectives
Bevrani, H., Ise, T., & Miura, Y. (2014) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2013.07.009 · Cited by 837
The Relevance of Inertia in Power Systems
Tielens, P., & Van Hertem, D. (2016) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2015.11.016 · Cited by 809
D'Arco, S., & Suul, J. A. (2013) · 2013 IEEE Grenoble Conference · doi:10.1109/ptc.2013.6652456 · Cited by 443
Grid-forming control for power converters based on matching of synchronous machines
Arghir, C., Jouini, T., & Dörfler, F. (2018) · Automatica · doi:10.1016/j.automatica.2018.05.037 · Cited by 263
Impacts of distributed generation on power system transient stability
Slootweg, J. G., & Kling, W. L. (2003) · IEEE Power Engineering Society Summer Meeting, · doi:10.1109/pess.2002.1043465 · Cited by 259
Denis, G., Prevost, T., Debry, M., Xavier, F., Guillaud, X., & Menze, A. (2018) · IET Renewable Power Generation · doi:10.1049/iet-rpg.2017.0369 · Cited by 172
Moeini, A., Kamwa, I., Brunelle, P., & Sybille, G. (2015) · International Universities Power Engineering Conference (UPEC) · doi:10.1109/upec.2015.7339813 · Cited by 156
Taylor, J. A., Dhople, S. V., & Callaway, D. S. (2016) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2015.12.083 · Cited by 121
Winter, W., Elkington, K., Bareux, G., & Kostevc, J. (2014) · IEEE Power and Energy Magazine · doi:10.1109/mpe.2014.2363534 · Cited by 113
Dynamic frequency control with increasing wind generation
Lalor, G., Ritchie, J., Rourke, S., Flynn, D., & O’Malley, M. (2004) · IEEE Power Engineering Society General Meeting · doi:10.1109/pes.2004.1373170 · Cited by 113
Optimizing DER Participation in Inertial and Primary-Frequency Response
Guggilam, S. S., Zhao, C., Dall’Anese, E., Chen, Y. C., & Dhople, S. V. (2018) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2018.2798540 · Cited by 108
Global Analysis of Synchronization Performance for Power Systems: Bridging the Theory-Practice Gap
Paganini, F., & Mallada, E. (2019) · IEEE Transactions on Automatic Control · doi:10.1109/tac.2019.2942536 · Cited by 76
Cvetkovic, I., Boroyevich, D., Burgos, R. P., Li, C., & Mattavelli, P. (2015) · IEEE ... Workshop on Control and Modeling for Power Electronics · doi:10.1109/compel.2015.7236454 · Cited by 68
Increasing the Resilience of Low-inertia Power Systems by Virtual Inertia and Damping
Groß, D., Bolognani, S., Poolla, B. K., & Dörfler, F. (2017) · Repository for Publications and Research Data (ETH Zurich) · doi:10.3929/ethz-b-000232185 · Cited by 58
Self-citationTayyebi, A., Dörfler, F., Kupzog, F., Miletic, Z., & Hribernik, W. (2018) · CIRED · doi:10.34890/412 · Cited by 57
Control of low-inertia power grids: A model reduction approach
Curi, S., Groß, D., & Dörfler, F. (2017) · IEEE Conference on Decision and Control (CDC) · doi:10.1109/cdc.2017.8264521 · Cited by 53
H∞ Performance of Mechanical and Power Networks
Pirani, M., Hashemi, E., Fi̇dan, B., & Simpson-Porco, J. W. (2017) · IFAC-PapersOnLine · doi:10.1016/j.ifacol.2017.08.453 · Cited by 7
Cited by
Grid Forming Inverter Modeling, Control, and Applications
Rathnayake, D. B., Akrami, M., Phurailatpam, C., Me, S. P., Hadavi, S., Jayasinghe, G., Zabihi, S., & Bahrani, B. (2021) · IEEE Access · doi:10.1109/access.2021.3104617 · Cited by 630
Frequency Stability of Synchronous Machines and Grid-Forming Power Converters
Tayyebi, A., Gross, D., Anta, A., Kupzog, F., & Dorfler, F. (2020) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2020.2966524 · Cited by 442
Understanding Small-Signal Stability of Low-Inertia Systems
Markovic, U., Stanojev, O., Aristidou, P., Vrettos, E., Callaway, D., & Hug, G. (2021) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2021.3061434 · Cited by 370
Meng, L., Zafar, J., Khadem, S. K., Collinson, A., Murchie, K. C., Coffele, F., & Burt, G. M. (2020) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2019.2940173 · Cited by 364
Resilience of renewable power systems under climate risks
Xu, L., Feng, K., Lin, N., Perera, A. T. D., Poor, H. V., Xie, L., Ji, C., Sun, X. A., Guo, Q., & O’Malley, M. (2024) · Nature Reviews Electrical Engineering · doi:10.1038/s44287-023-00003-8 · Cited by 293
Metadata
- Authors
- Poolla, B. K., Gros, D., & Dorfler, F.
- Venue
- IEEE Transactions on Power Systems
- Published
- 2019-07
- Volume
- 34
- Issue
- 4
- Pages
- 3035-3046
- ISSN
- 0885-8950 (ISSN-L)
- 1558-0679
- OpenAlex
- W2898968226
- Cited by
- 400
- References
- 26
- FWCI
- 23.31
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.