The DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.
Needle insertion modeling and simulation
Abstract
A methodology for estimating the force distribution that occurs along a needle shaft during insertion is described. An experimental system for measuring planar tissue phantom deformation during needle insertions has been developed and is presented. A two-dimensional linear elastostatic material model, discretised using the finite element method, is used to derive contact force information that is not directly measurable. This approach provides a method for quantifying the needle forces and soft tissue deformations that occur during general needle trajectories in multiple dimensions. The needle force distribution is used for graphical and haptic real-time simulations of needle insertion. Since the force displacement relationship is required only along the needle, a condensation technique is shown to achieve very fast interactive simulations. Stiffness matrix changes corresponding to changes in boundary conditions and material coordinate frames are performed using low-rank matrix updates.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A four-step camera calibration procedure with implicit image correction
Heikkila, J., & Silven, O. (2002) · Proceedings of IEEE Computer Society Conference on Computer Vision and Pattern Recognition · doi:10.1109/cvpr.1997.609468 · Cited by 2,051
Real-time elastic deformations of soft tissues for surgery simulation
Cotin, S., Delingette, H., & Ayache, N. (1999) · IEEE Transactions on Visualization and Computer Graphics · doi:10.1109/2945.764872 · Cited by 729
A First Course in Continuum Mechanics
Gonzalez, O., & Stuart, A. M. (2001) · Cambridge University Press eBooks · doi:10.1017/cbo9780511619571 · Cited by 601
A first course in continuum mechanics
Fung, Y. C. (1969) · Medical Entomology and Zoology · Cited by 550
Mechanical properties of brain tissue in-vivo: experiment and computer simulation
Miller, K., Chinzei, K., Orssengo, G., & Bednarz, P. (2000) · Journal of Biomechanics · doi:10.1016/s0021-9290(00)00120-2 · Cited by 501
ArtDefo: accurate real time deformable objects
James, D. L., & Pai, D. K. (1999) · Proceedings of the 26th annual conference on Computer graphics and interactive techniques - SIGGRAPH '99 · doi:10.1145/311535.311542 · Cited by 498
Finite Element Methods and Navier-Stokes Equations
Cuvelier, C., Segal, A., & van Steenhoven, A. A. (1986) · Springer eBooks · doi:10.1007/978-94-010-9333-0 · Cited by 422
Finite element modeling in surgery simulation
Bro-Nielsen, M. (1998) · Proceedings of the IEEE · doi:10.1109/5.662874 · Cited by 401
Modeling of needle insertion forces for robot-assisted percutaneous therapy
Simone, C., & Okamura, A. M. (2003) · Proceedings 2002 IEEE International Conference on Robotics and Automation (Cat. No.02CH37292) · doi:10.1109/robot.2002.1014848 · Cited by 200
Measuring in vivo animal soft tissue properties for haptic modeling in surgical simulation.
Brouwer, I., Ustin, J. S., Bentley, L., Sherman, A., Dhruv, N. T., & Tendick, F. (2001) · PubMed · Cited by 180
Dosimetric effects of needle divergence in prostate seed implant using and radioactive seeds
Nath, S. K., Chen, Z., Yue, N. J., Trumpore, S., & Peschel, R. E. (2000) · Medical Physics · doi:10.1118/1.598971 · Cited by 119
Finite element methods and Navier-Stokes equations
Raviart, P.-A. (2008) · Springer eBooks · doi:10.1007/3-540-09119-x_91 · Cited by 106
Thao, D., Annaswamy, T. M., & Srinivasan, M. A. (2001) · Studies in health technology and informatics · doi:10.3233/978-1-60750-925-7-97 · Cited by 99
A robotic system for blood sampling
Zivanovic, A., & Davies, B. (2000) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/4233.826854 · Cited by 73
Realistic force reflection in a spine biopsy simulator
Kwon, D., Kyung, K., Kwon, S. M., et al. (2002) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/robot.2001.932799 · Cited by 34
Cited by
Force Modeling for Needle Insertion Into Soft Tissue
Okamura, A. M., Simone, C., & O'Leary, M. D. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.831542 · Cited by 830
Needle insertion into soft tissue: A survey
Abolhassani, N., Patel, R., & Moallem, M. (2007) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2006.07.003 · Cited by 704
Nonholonomic Modeling of Needle Steering
Webster, R. J., Kim, J. S., Cowan, N. J., Chirikjian, G. S., & Okamura, A. M. (2006) · The International Journal of Robotics Research · doi:10.1177/0278364906065388 · Cited by 633
Nonholonomic Modeling of Needle Steering
Webster, R. J., Cowan, N. J., Chirikjian, G., & Okamura, A. M. (2006) · Springer Tracts in Advanced Robotics · doi:10.1007/11552246_4 · Cited by 527
Mechanics of Precurved-Tube Continuum Robots
Webster, R. J., Romano, J. M., & Cowan, N. J. (2009) · IEEE Transactions on Robotics · doi:10.1109/tro.2008.2006868 · Cited by 485
Metadata
- Authors
- DiMaio, S. P., & Salcudean, S. E.
- Venue
- IEEE Transactions on Robotics and Automation
- Published
- 2003-10
- Volume
- 19
- Issue
- 5
- Pages
- 864-875
- ISSN
- 1042-296X (ISSN-L)
- OpenAlex
- W2754300823
- Cited by
- 518
- References
- 15
- FWCI
- 17.42
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.