The DOI matches its Crossref record; 43 of the 43 references it cites were found in a registry or an index.
Needle insertion into soft tissue: A survey
Abstract
Needle insertion in soft tissue has attracted considerable attention in recent years due to its application in minimally invasive percutaneous procedures such as biopsies and brachytherapy. This paper presents a survey of the current state of research on needle insertion in soft tissue. It examines the topic from several aspects, e.g. modeling needle insertion forces, modeling tissue deformation and needle deflection during insertion, robot-assisted needle insertion, and the effect of different trajectories on tissue deformation. All studies show that the axial force of a needle during insertion in soft tissue is the summation of different forces distributed along the needle shaft such as stiffness force, frictional force and cutting force. Some studies have modeled these forces. The force data in some procedures is used for identifying tissue layers as the needle is inserted or for path planning. Needle deflection and tissue deformation are major problems for accurate needle insertion and attempts have been made to model them. Using current models several insertion techniques have been developed which are briefly reviewed in this paper.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Zienkiewicz, O. C. (1989) · Cited by 14,802
To Err Is Human: Building a Safer Health System
(2000) · National Academies Press eBooks · doi:10.17226/9728 · Cited by 14,044
To Err is Human: Building a Safer Health System
Hendee, W. R. (2001) · Journal of Vascular and Interventional Radiology · doi:10.1016/s1051-0443(01)70072-3 · Cited by 10,103
Biomechanics. Mechanical Properties of Living Tissues
Fung, Y. C., & Skalak, R. (1982) · Journal of Applied Mechanics · doi:10.1115/1.3162171 · Cited by 6,025
Nonlinear programming: theory and algorithms
(1993) · Computers & Operations Research · doi:10.1016/0305-0548(93)90042-h · Cited by 5,779
Barry Issenberg, S., Mcgaghie, W. C., Petrusa, E. R., Lee Gordon, D., & Scalese, R. J. (2005) · Medical Teacher · doi:10.1080/01421590500046924 · Cited by 3,966
Biomechanics: Mechanical Properties of Living Tissues
Fung, Y. C., & Skalak, R. (1981) · Journal of Biomechanical Engineering · doi:10.1115/1.3138285 · Cited by 2,769
Elastic Moduli of Breast and Prostate Tissues under Compression
Krouskop, T. A., Wheeler, T. M., Kallel, F., Garra, B. S., & Hall, T. (1998) · Ultrasonic Imaging · doi:10.1177/016173469802000403 · Cited by 1,703
Nonlinear programming: Theory and algorithms
Plastria, F. (1994) · European Journal of Operational Research · doi:10.1016/0377-2217(94)90039-6 · Cited by 1,467
Cited by
Microneedle, bio-microneedle and bio-inspired microneedle: A review
Ma, G., & Wu, C. (2017) · Journal of Controlled Release · doi:10.1016/j.jconrel.2017.02.011 · Cited by 477
Mechanics of Flexible Needles Robotically Steered through Soft Tissue
Misra, S., Reed, K. B., Schafer, B. W., Ramesh, K. T., & Okamura, A. M. (2010) · The International Journal of Robotics Research · doi:10.1177/0278364910369714 · Cited by 314
DLR MiroSurge: a versatile system for research in endoscopic telesurgery
Hagn, U., Konietschke, R., Tobergte, A., Nickl, M., Jörg, S., Kübler, B., Passig, G., Gröger, M., Fröhlich, F., Seibold, U., et al. (2010) · International Journal of Computer Assisted Radiology and Surgery · doi:10.1007/s11548-009-0372-4 · Cited by 270
Cutaneous force feedback as a sensory subtraction technique in haptics
Prattichizzo, D., Pacchierotti, C., & Rosati, G. (2012) · IEEE Transactions on Haptics · doi:10.1109/toh.2012.15 · Cited by 172
Metadata
- Authors
- Abolhassani, N., Patel, R., & Moallem, M.
- Venue
- Medical Engineering & Physics
- Publisher
- IOP Publishing
- Published
- 2006-08-28
- Volume
- 29
- Issue
- 4
- Pages
- 413-431
- ISSN
- 1350-4533 (ISSN-L)
- 1873-4030
- OpenAlex
- W2090415875
- Cited by
- 704
- References
- 43
- FWCI
- 12.19
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Needle insertion into soft tissue: A survey. https://app.cochat.ai/papers/10.1016/j.medengphy.2006.07.003
- The paper
- Abolhassani, N., Patel, R., & Moallem, M. (2007). Needle insertion into soft tissue: A survey. Medical Engineering & Physics. https://doi.org/10.1016/j.medengphy.2006.07.003
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.