A Hybrid Motion Classification Approach for EMG-Based Human–Robot Interfaces Using Bayesian and Neural Networks
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
In a human-robot interface, the prediction of motion, which is based on context information of a task, has the potential to improve the robustness and reliability of motion classification to control prosthetic devices or human-assisting manipulators. This paper proposes a task model using a Bayesian network (BN) for motion prediction. Given information of the previous motion, this task model is able to predict occurrence probabilities of the motions concerned in the task. Furthermore, a hybrid motion classification framework has been developed based on the BN motion prediction. Besides the motion prediction, electromyogram (EMG) signals are simultaneously classified by a probabilistic neural network (NN). Then, the motion occurrence probabilities are combined with the NN classifier's outputs to generate motion commands for control. With the proposed motion classification framework, it is expected that classification performance can be enhanced so that motion commands can be more robust and reliable. Experiments have been conducted with four subjects to demonstrate the feasibility of the proposed methods. In these experiments, forearm motions are classified with EMG signals considering a cooking task. Finally, robot manipulation experiments were carried out to verify the proposed human interface system with a task of taking meal. The experimental results indicate that the proposed methods improved the robustness and stability of motion classification.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A new strategy for multifunction myoelectric control
Hudgins, B., Parker, P., & Scott, R. N. (1993) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.204774 · Cited by 2,149
Control of Multifunctional Prosthetic Hands by Processing the Electromyographic Signal
Zecca, M., Micera, S., Carrozza, M. C., & Dario, P. (2002) · Critical Reviews? in Biomedical Engineering · doi:10.1615/critrevbiomedeng.v30.i456.80 · Cited by 606
Micera, S., Sabatini, A. M., Dario, P., & Rossi, B. (1999) · Medical Engineering & Physics · doi:10.1016/s1350-4533(99)00055-7 · Cited by 90
Cited by
Brain Computer Interfaces, a Review
Nicolas-Alonso, L. F., & Gomez-Gil, J. (2012) · Sensors · doi:10.3390/s120201211 · Cited by 2,143
“EMG computer interface [201], human-computer interface (HCI) [202], EMG-based human-computer interface [203], EMG-Based Human-Machine Interface [204], EMG-based human-robot interface [205], muscle-computer interface (MuCI) [206], man-machine interface (MMI) [207], and biocontroller interface [208] are different”
BackgroundPang, M., Guo, S., Huang, Q., Ishihara, H., & Hirata, H. (2015) · Journal of Medical and Biological Engineering · doi:10.1007/s40846-015-0033-8 · Cited by 53
A strain gauge based locomotion mode recognition method using convolutional neural network
Feng, Y., Chen, W., & Wang, Q. (2019) · Advanced Robotics · doi:10.1080/01691864.2018.1563500 · Cited by 28
Metadata
- Authors
- Bu, N., Okamoto, M., & Tsuji, T.
- Venue
- IEEE Transactions on Robotics
- Published
- 2009-06
- Volume
- 25
- Issue
- 3
- Pages
- 502-511
- ISSN
- 1552-3098 (ISSN-L)
- 1941-0468
- OpenAlex
- W2111593098
- Cited by
- 159
- References
- 3
- FWCI
- 7.96
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.