The DOI matches its Crossref record.
Control of Multiple Heterogeneous Magnetic Microrobots in Two Dimensions on Nonspecialized Surfaces
Abstract
In this paper, we propose methods to control multiple untethered magnetic microrobots (called Mag-μBots), with all dimensions under 1 mm, without the need for a specialized surface. We investigate sets of Mag-μBots that are geometrically designed to respond uniquely to the same applied magnetic fields. By controlling the magnetic field waveforms, individual and subgroups of Mag-μBots are able to locomote in a parallel but dissimilar fashion. The control of geometrically dissimilar Mag-μBots and a group of identically fabricated Mag-μBots are investigated, and control strategies are developed for 1-D and 2-D motion. This is accomplished by learning the velocity response of each microrobot to various control signals and using the uniqueness of each microrobot response to achieve independent control. The effect of high-level control parameters are investigated in simulation and in experiments, and the simultaneous independent global positioning of two and three microrobots is demonstrated in 2-D space. As this control method is accomplished without the use of a specialized surface, it has potential applications in areas such as microfluidic systems and biomanipulation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Soft Actuators for Small-Scale Robotics
Hines, L., Petersen, K., Lum, G. Z., & Sitti, M. (2017) · Advanced Materials · doi:10.1002/adma.201603483 · Cited by 1,337
Self-citationBio-inspired magnetic swimming microrobots for biomedical applications
Peyer, K. E., Zhang, L., & Nelson, B. J. (2013) · Nanoscale · doi:10.1039/c2nr32554c · Cited by 820
Soft Actuators for Soft Robotic Applications: A Review
El-Atab, N., Mishra, R. B., Al-Modaf, F., Joharji, L., Alsharif, A. A., Alamoudi, H., Diaz, M., Qaiser, N., & Hussain, M. M. (2020) · Advanced Intelligent Systems · doi:10.1002/aisy.202000128 · Cited by 552
Pros and Cons: Magnetic versus Optical Microrobots
Sitti, M., & Wiersma, D. S. (2020) · Advanced Materials · doi:10.1002/adma.201906766 · Cited by 398
Self-citationMagnetic Actuation Systems for Miniature Robots: A Review
Yang, Z., & Zhang, L. (2020) · Advanced Intelligent Systems · doi:10.1002/aisy.202000082 · Cited by 388
Multifunctional magnetic soft composites: a review
Wu, S., Hu, W., Ze, Q., Sitti, M., & Zhao, R. (2020) · Multifunctional Materials · doi:10.1088/2399-7532/abcb0c · Cited by 307
Self-citationUntethered micro-robotic coding of three-dimensional material composition
Tasoglu, S., Diller, E., Guven, S., Sitti, M., & Demirci, U. (2014) · Nature Communications · doi:10.1038/ncomms4124 · Cited by 293
Self-citationIndependent control of multiple magnetic microrobots in three dimensions
Diller, E., Giltinan, J., & Sitti, M. (2013) · The International Journal of Robotics Research · doi:10.1177/0278364913483183 · Cited by 267
Self-citationControl Strategies for Soft Robot Systems
Wang, J., & Chortos, A. (2022) · Advanced Intelligent Systems · doi:10.1002/aisy.202100165 · Cited by 254
Dong, X., & Sitti, M. (2020) · The International Journal of Robotics Research · doi:10.1177/0278364920903107 · Cited by 198
Self-citation
Metadata
- Authors
- Diller, E., Floyd, S., Pawashe, C., & Sitti, M.
- Venue
- IEEE Transactions on Robotics
- Published
- 2012-02
- Volume
- 28
- Issue
- 1
- Pages
- 172-182
- ISSN
- 1552-3098 (ISSN-L)
- 1941-0468
- OpenAlex
- W2063377555
- Cited by
- 184
- References
- 0
- FWCI
- 8.69
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.