Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 409

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Design of a Cable-Driven Arm Exoskeleton (CAREX) for Neural Rehabilitation

Mao, Ying, Agrawal, Sunil Kumar·2012·IEEE Transactions on Robotics

Abstract

Rehabilitation robots are, currently, being explored for training of neural impaired subjects or for assistance of those with weak limbs. Intensive training of neurally impaired subjects, with quantifiable outcomes, is the eventual goal of these robot exoskeletons. Conventional arm exoskeletons for rehabilitation are bulky and heavy. In recent years, the authors have proposed to make lightweight exoskeletons for rehabilitation by replacing the rigid links of the exoskeleton with lightweight cuffs fixed to the moving limb segments of the human arm. Cables are routed through these cuffs, which are driven by motors, to move the limb segments relative to each other. However, a scientific limitation of a cable-driven system is that each cable can only pull but not push. This paper is the first to demonstrate via experiments with cable-driven arm exoskeleton (CAREX) that it is possible to achieve desired forces on the hand, i.e., both pull and push, in any direction as required in neural training. In this research, an anthropomorphic arm was used to bench test the design and control concepts proposed in CAREX. As described in this paper, CAREX was attached to the limb segments of a five degree-of-freedom anthropomorphic arm instrumented with joint sensors. The cuffs of CAREX were designed to have adjustable cable routing points to optimize the “tensioned” workspace of the anthropomorphic arm. Simulation results of force field for training and rehabilitation of the arm are first presented. Experiments are conducted to show the performance of a CAREX force field controller when human subjects pull the end-effector of the anthropomorphic arm to travel on prescribed paths. The human-exoskeleton interface is also presented at the end of this paper to demonstrate the feasibility of CAREX on human arm.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tro.2012.2189496

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 409

Metadata

Authors
Mao, Y., & Agrawal, S. K.
Venue
IEEE Transactions on Robotics
Published
2012-08
Volume
28
Issue
4
Pages
922-931
ISSN
  • 1552-3098 (ISSN-L)
  • 1941-0468
OpenAlex
W1972239908
Cited by
409
References
3
FWCI
10.81
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Design of a Cable-Driven Arm Exoskeleton (CAREX) for Neural Rehabilitation. https://app.cochat.ai/papers/10.1109/tro.2012.2189496
The paper
Mao, Y., & Agrawal, S. K. (2012). Design of a Cable-Driven Arm Exoskeleton (CAREX) for Neural Rehabilitation. IEEE Transactions on Robotics. https://doi.org/10.1109/tro.2012.2189496

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.