The DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.
Design of a Cable-Driven Arm Exoskeleton (CAREX) for Neural Rehabilitation
Abstract
Rehabilitation robots are, currently, being explored for training of neural impaired subjects or for assistance of those with weak limbs. Intensive training of neurally impaired subjects, with quantifiable outcomes, is the eventual goal of these robot exoskeletons. Conventional arm exoskeletons for rehabilitation are bulky and heavy. In recent years, the authors have proposed to make lightweight exoskeletons for rehabilitation by replacing the rigid links of the exoskeleton with lightweight cuffs fixed to the moving limb segments of the human arm. Cables are routed through these cuffs, which are driven by motors, to move the limb segments relative to each other. However, a scientific limitation of a cable-driven system is that each cable can only pull but not push. This paper is the first to demonstrate via experiments with cable-driven arm exoskeleton (CAREX) that it is possible to achieve desired forces on the hand, i.e., both pull and push, in any direction as required in neural training. In this research, an anthropomorphic arm was used to bench test the design and control concepts proposed in CAREX. As described in this paper, CAREX was attached to the limb segments of a five degree-of-freedom anthropomorphic arm instrumented with joint sensors. The cuffs of CAREX were designed to have adjustable cable routing points to optimize the “tensioned” workspace of the anthropomorphic arm. Simulation results of force field for training and rehabilitation of the arm are first presented. Experiments are conducted to show the performance of a CAREX force field controller when human subjects pull the end-effector of the anthropomorphic arm to travel on prescribed paths. The human-exoskeleton interface is also presented at the end of this paper to demonstrate the feasibility of CAREX on human arm.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Upper-Limb Powered Exoskeleton Design
Perry, J. C., Rosen, J., & Burns, S. (2007) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2007.901934 · Cited by 1,023
Bütefisch, C., Hummelsheim, H., Denzler, P., & Mauritz, K.-H. (1995) · Journal of the Neurological Sciences · doi:10.1016/0022-510x(95)00003-k · Cited by 840
Robot assisted gait training with Active Leg Exoskeleton (ALEX)
Banala, S. K., Kim, S. H., Agrawal, S. K., & Scholz, J. P. (2009) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2008.2008280 · Cited by 751
Effects of Intensity of Rehabilitation After Stroke: A Research Synthesis
Kwakkel, G., Wagenaar, R. C., Koelman, T. W., Lankhorst, G. J., & Koetsier, J. C. (1997) · Stroke · doi:10.1161/01.str.28.8.1550 · Cited by 589
ARMin III – Arm Therapy Exoskeleton with an Ergonomic Shoulder Actuation
Nef, T., Guidali, M., & Riener, R. (2009) · Applied Bionics and Biomechanics · doi:10.1080/11762320902840179 · Cited by 522
The Effect of Robot-Assisted Therapy and Rehabilitative Training on Motor Recovery Following Stroke
Aisen, M. L., Krebs, H. I., Hogan, N., McDowell, F., & Volpe, B. T. (1997) · Archives of Neurology · doi:10.1001/archneur.1997.00550160075019 · Cited by 516
Path Control: A Method for Patient-Cooperative Robot-Aided Gait Rehabilitation
Duschau-Wicke, A., von Zitzewitz, J., Caprez, A., Lunenburger, L., & Riener, R. (2010) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2009.2033061 · Cited by 421 · cited 1×
““Assist-as-needed” training paradigm, which has been shown effective for rehabilitation [24]–[26], was adopted.”
BackgroundThe Role of Task-Specific Training in Rehabilitation Therapies
Bayona, N. A., Bitensky, J., Salter, K., & Teasell, R. (2005) · Topics in Stroke Rehabilitation · doi:10.1310/bqm5-6ygb-mvj5-wvcr · Cited by 411
Sunderland, A., Tinson, D. J., Bradley, E. L., Fletcher, D., Langton Hewer, R., & Wade, D. T. (1992) · Journal of Neurology, Neurosurgery & Psychiatry · doi:10.1136/jnnp.55.7.530 · Cited by 332
Analysis of the Workspace of Tendon-based Stewart Platforms
Verhoeven, R. (2004) · DuEPublico (University of Duisburg-Essen) · Cited by 201
Emken, J. L., Benitez, R., & Reinkensmeyer, D. J. (2007) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-4-8 · Cited by 199
MEDARM: a rehabilitation robot with 5DOF at the shoulder complex
Ball, S. J., Brown, I. E., & Scott, S. H. (2007) · 2007 IEEE/ASME international conference on advanced intelligent mechatronics · doi:10.1109/aim.2007.4412446 · Cited by 188
ARMin - Design of a Novel Arm Rehabilitation Robot
Nef, T., & Riener, R. (2005) · 9th International Conference on Rehabilitation Robotics, 2005. ICORR 2005. · doi:10.1109/icorr.2005.1501051 · Cited by 180
Design of an arm exoskeleton with scapula motion for shoulder rehabilitation
Roderick, S., Liszka, M., & Carignan, C. (2005) · ICAR '05. Proceedings., 12th International Conference on Advanced Robotics, 2005. · doi:10.1109/icar.2005.1507459 · Cited by 178
A cable driven upper arm exoskeleton for upper extremity rehabilitation
Mao, Y., & Agrawal, S. K. (2011) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/icra.2011.5980142 · Cited by 57
Self-citationTraining Toddlers Seated on Mobile Robots to Drive Indoors Amidst Obstacles
Chen, X., Ragonesi, C. B., Galloway, J. C., & Agrawal, S. K. (2011) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2011.2114370 · Cited by 38
Self-citationMao, Y., & Agrawal, S. K. (2010) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/robot.2010.5509823 · Cited by 31
Self-citation
Cited by
A decade retrospective of medical robotics research from 2010 to 2020
Dupont, P. E., Nelson, B. J., Goldfarb, M., Hannaford, B., Menciassi, A., O’Malley, M. K., Simaan, N., Valdastri, P., & Yang, G.-Z. (2021) · Science Robotics · doi:10.1126/scirobotics.abi8017 · Cited by 516
Developments in hardware systems of active upper-limb exoskeleton robots: A review
Gopura, R. A. R. C., Bandara, D. S. V., Kiguchi, K., & Mann, G. K. I. (2016) · Robotics and Autonomous Systems · doi:10.1016/j.robot.2015.10.001 · Cited by 480
Losey, D. P., McDonald, C. G., Battaglia, E., & O'Malley, M. K. (2018) · Applied Mechanics Reviews · doi:10.1115/1.4039145 · Cited by 392
Upper-Limb Robotic Exoskeletons for Neurorehabilitation: A Review on Control Strategies
Proietti, T., Crocher, V., Roby-Brami, A., & Jarrasse, N. (2016) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2016.2552201 · Cited by 388
Minimal Assist-as-Needed Controller for Upper Limb Robotic Rehabilitation
Pehlivan, A. U., Losey, D. P., & O'Malley, M. K. (2016) · IEEE Transactions on Robotics · doi:10.1109/tro.2015.2503726 · Cited by 275
Metadata
- Authors
- Mao, Y., & Agrawal, S. K.
- Venue
- IEEE Transactions on Robotics
- Published
- 2012-08
- Volume
- 28
- Issue
- 4
- Pages
- 922-931
- ISSN
- 1552-3098 (ISSN-L)
- 1941-0468
- OpenAlex
- W1972239908
- Cited by
- 409
- References
- 17
- FWCI
- 10.81
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.