A Small-Gain Approach for Nonpassive Bilateral Telerobotic Rehabilitation: Stability Analysis and Controller Synthesis
The DOI matches its Crossref record; 36 of the 36 references it cites were found in a registry or an index.
Abstract
In this paper, the design of a novel bilateral telerobotic architecture for rehabilitation purposes is proposed and the related feasibility, stability, and control challenges are studied. The objective is to incorporate the supervision of a local/remote human physiotherapist into haptics-enabled rehabilitation systems and allow the therapist to provide nonpassive nonlinear assistive/resistive forces in response to the patient's movements. This can address a challenge of conventional software-based rehabilitation systems, i.e., limited capability in adjusting the therapy. To guarantee human-robot interaction safety, a new design framework and a stabilizing controller are developed based on the small-gain approach. System stability and transparency are analyzed in the presence of the nonpassive, nonlinear, and nonautonomous behavior of the terminals (the therapist and the patient) and time-varying delays for the case of remote and cloud-based therapy. Several practical considerations have been taken into account to match the clinical needs and minimize the implementation cost. Simulation studies, practical implementation, and experimental evaluations are presented.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“It is worth noting that phase lag (even in the order of 10 ms) can easily make a high-gain rehabilitation robot unstable which can sacrifice safety13,56–59.”
From PHTNet: Characterization and Deep Mining of Involuntary Pathological Hand Tremor using Recurrent Neural Network Models (2020) · cites this paper as [56]
Citations
Cites
Stability and transparency in bilateral teleoperation
Lawrence, D. A. (1993) · IEEE Transactions on Robotics and Automation · doi:10.1109/70.258054 · Cited by 2,061
Linear controller design: limits of performance
Boyd, S., & Barratt, C. H. (1991) · Prentice-Hall, Inc eBooks · Cited by 1,196
Review of control strategies for robotic movement training after neurologic injury
Marchal-Crespo, L., & Reinkensmeyer, D. J. (2009) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-6-20 · Cited by 1,182
Input to State Stability: Basic Concepts and Results
Sontag, E. D. (2008) · Lecture Notes in Mathematics · doi:10.1007/978-3-540-77653-6_3 · Cited by 1,181 · cited 1×
“fer matrix is proper; in this case, the peak gain of a system is equal to its IOS gain [28].”
BackgroundTime-domain passivity control of haptic interfaces
Hannaford, B., & Ryu, J.-H. (2002) · IEEE Transactions on Robotics and Automation · doi:10.1109/70.988969 · Cited by 767
Rehabilitation Robotics: Performance-Based Progressive Robot-Assisted Therapy
Krebs, H. I., Palazzolo, J. J., Dipietro, L., Ferraro, M., Krol, J., Rannekleiv, K., Volpe, B. T., & Hogan, N. (2003) · Autonomous Robots · doi:10.1023/a:1024494031121 · Cited by 714 · cited 1×
“of impairment, body dynamics, and needs for rehabilitation [11]–[13].”
BackgroundDissipative systems analysis and control theory and applications
Lozano, R. (2000) · Cited by 647
Stable haptic interaction with virtual environments
Adams, R. J., & Hannaford, B. (1999) · IEEE Transactions on Robotics and Automation · doi:10.1109/70.768179 · Cited by 646 · cited 1×
“An example can be the definition of Z width developed in the literature for linear haptic rendering systems [31].”
BackgroundEpidemiology and the Global Burden of Stroke
Mukherjee, D., & Patil, C. G. (2011) · World Neurosurgery · doi:10.1016/j.wneu.2011.07.023 · Cited by 644 · cited 1×
“It is anticipated that the population of people suffering a stroke worldwide each year will reach 23 million by 2030 [3].”
BackgroundDissipative Systems Analysis and Control
Lozano, R., Brogliato, B., Egeland, O., & Maschke, B. (2000) · Communications and Control Engineering · doi:10.1007/978-1-4471-3668-2 · Cited by 554
Cited by
Haptic Feedback and Force-Based Teleoperation in Surgical Robotics
Patel, R. V., Atashzar, S. F., & Tavakoli, M. (2022) · Proceedings of the IEEE · doi:10.1109/jproc.2022.3180052 · Cited by 200
“Using small gain control, the aforementioned assumptions are relaxed, and variable time delays are also considered to propose several new categories of stabilizers that guarantee system stability while reducing deterioration in transparency by decreasing the conservatism of the system [92]–[94], [127], [129], [130], […”
BackgroundInfluentialSelf-citationRobotics in Healthcare: A Survey
Silvera‐Tawil, D. (2024) · SN Computer Science · doi:10.1007/s42979-023-02551-0 · Cited by 184
“Telerobots can also support clinicians with other tasks, such as the remote evaluation and rehabilitation of upper-limb function [150, 151].”
Atashzar, S. F., Carriere, J., & Tavakoli, M. (2021) · Frontiers in Robotics and AI · doi:10.3389/frobt.2021.610529 · Cited by 75
“(2015); Atashzar et al. (2016b); Atashzar et al. (2017b); Atashzar et al. (2020)).”
BackgroundInfluentialSelf-citationHuman Lower Limb Motion Intention Recognition for Exoskeletons: A Review
Li, L., Cao, G., Liang, H., Zhang, Y.-P., & Cui, F. (2023) · IEEE Sensors Journal · doi:10.1109/jsen.2023.3328615 · Cited by 71
“HMIR not only involves signals from CNS and musculoskeletal dynamics but also concerns the past and current motion states and trajectories [233].”
BackgroundReview of Advanced Medical Telerobots
Mehrdad, S., Liu, F., Pham, M. T., Lelevé, A., & Atashzar, S. F. (2020) · Applied Sciences · doi:10.3390/app11010209 · Cited by 66
“Thus with the use of advanced technology, including ultra-fast communication, advanced instrumentation, and algorithmic stabilizers [7,64,82,85,150,166,180,181,184], it can be envisioned that the next generation of telerobotic surgical systems is equipped with means of high-fidelity haptics…”
InfluentialSelf-citationLiu, Y., Guo, S., Yang, Z., Hirata, H., & Tamiya, T. (2022) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2022.3176276 · Cited by 67
“are regarded as a nonlinear active network to inject nonpassive energy into the interconnection for providing assistance and coordination [31].”
BackgroundLuo, J., He, W., & Yang, C. (2020) · Cognitive Computation and Systems · doi:10.1049/ccs.2020.0005 · Cited by 53
Atashzar, S. F., Shahbazi, M., Tavakoli, M., & Patel, R. V. (2017) · The International Journal of Robotics Research · doi:10.1177/0278364916689139 · Cited by 41
“An example is the recently-developed Haptics-enabled Telerobotic Rehabilitation (HTR) system, proposed by the authors in Atashzar et al. (2015), Atashzar et al. (2012a), Atashzar et al. (2013), Atashzar et al.”
BackgroundMethodInfluentialSelf-citationAtashzar, S. F., Shahbazi, M., & Patel, R. V. (2018) · Mechatronics · doi:10.1016/j.mechatronics.2018.03.002 · Cited by 42
Self-citationPosition-Force Domain Passivity of the Human Arm in Telerobotic Systems
Shahbazi, M., Atashzar, S. F., Tavakoli, M., & Patel, R. V. (2018) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2018.2793877 · Cited by 38
“Teleoperation systems have been broadly used in a wide range of applications from mining to space and underwater exploration to robotics-assisted minimally invasive surgery [1], [2], robotic surgical training [3], [4], and robotics-assisted rehabilitation therapy [5], [6].”
BackgroundSelf-citationAtashzar, S. F., Shahbazi, M., Tavakoli, M., & Patel, R. V. (2018) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2018.2806918 · Cited by 38
“The sensory substitution is not as intuitive as directly reflecting back the kinesthetic forces, but it eliminates concerns regarding stability and safety of a closed-loop telerobotic rehabilitation architecture [21], [27].”
BackgroundMethodSelf-citationShahtalebi, S., Atashzar, S. F., Samotus, O., Patel, R. V., Jog, M. S., & Mohammadi, A. (2020) · Scientific Reports · doi:10.1038/s41598-020-58912-9 · Cited by 32
“It should be noted that the time resolution of signal processing plays a very important role when the control loop gain and the frequency of activations in a control system are high (such as the robotic rehabilitation devices) 56 .”
BackgroundSelf-citationZhang, Z., Niu, Y., Yan, Z., & Lin, S. (2018) · Applied Sciences · doi:10.3390/app8102005 · Cited by 35
A Review of Bilateral Teleoperation Control Strategies with Soft Environment
Deng, Y., Tang, Y., Yang, B., Zheng, W., Liu, S., & Liu, C. (2021) · International Conference on Advanced Robotics and Mechatronics (ICARM) · doi:10.1109/icarm52023.2021.9536056 · Cited by 29
“[51] designed a new bilateral rehabilitation teleoperation robot structure, which incorporated the supervision of local/remote human physiotherapists into the rehabilitation system, and allowed the therapists to provide nonlinear force to respond to the movement of patients, solving the challenge of traditional softwa…”
A Survey of Technologies Facilitating Home and Community-Based Stroke Rehabilitation
Sun, X., Ding, J., Dong, Y., Ma, X., Wang, R., Jin, K., Zhang, H., & Zhang, Y. (2022) · International Journal of Human-Computer Interaction · doi:10.1080/10447318.2022.2050545 · Cited by 26
“Atashzar et al. (2017) introduced a non-passive bilateral telerobotic rehabilitation system, allowing the therapist to provide non-passive nonlinear assistive/resistive forces in response to the patient’s movement, consisting of master and slave haptic devices on both sides.”
BackgroundControl of bilateral teleoperators with time delays using only position measurements
Nuño, E., Arteaga, M. A., & Espinosa–Pérez, G. (2017) · International Journal of Robust and Nonlinear Control · doi:10.1002/rnc.3903 · Cited by 26
Batty, T., Ehrampoosh, A., Shirinzadeh, B., Zhong, Y., & Smith, J. A. (2022) · Sensors · doi:10.3390/s22249770 · Cited by 24
“As an alternative to passivity-based control, there is the small gain control theory [25], which does not require the assumption of passivity of system components since it deals with the overall loop gain of the system.”
BackgroundPassive Multiuser Teleoperation of a Multirobot System With Connectivity-Preserving Containment
Yang, Y., Constantinescu, D., & Shi, Y. (2021) · IEEE Transactions on Robotics · doi:10.1109/tro.2021.3086685 · Cited by 24
Cloud-supported framework for patients in post-stroke disability rehabilitation
Hossain, M. S., Hoda, M., Muhammad, G., Almogren, A., & Alamri, A. M. (2017) · Telematics and Informatics · doi:10.1016/j.tele.2017.12.001 · Cited by 20
Split-Crank Functional Electrical Stimulation Cycling: An Adapting Admitting Rehabilitation Robot
Cousin, C. A., Rouse, C. A., & Dixon, W. E. (2020) · IEEE Transactions on Control Systems Technology · doi:10.1109/tcst.2020.3032474 · Cited by 19
A review on human intent understanding and compliance control strategies for lower limb exoskeletons
Yang, J., He, Y., Shi, P. A., & Yu, H. (2022) · Proceedings of the Institution of Mechanical Engineers Part I Journal of Systems and Control Engineering · doi:10.1177/09596518221085793 · Cited by 22
Scattering-based stabilization of non-planar conic systems
Usova, A. A., Polushin, I. G., & Patel, R. V. (2018) · Automatica · doi:10.1016/j.automatica.2018.03.028 · Cited by 18
Self-citationDynamic gain control of teleoperating cyber-physical system with time-varying delay
Yan, J., Yang, X., Luo, X., & Guan, X. (2019) · Nonlinear Dynamics · doi:10.1007/s11071-018-04740-6 · Cited by 17
Feizi, N., Patel, R. V., Kermani, M. R., & Atashzar, S. F. (2022) · IEEE Transactions on Robotics · doi:10.1109/tro.2022.3158195 · Cited by 16
“Variable structure passivity signature control (VSPSC) is proposed recently to further reduce the complexity of nonlinear formulation, and result in smoother outcomes in the power domain considering not only the lower bound, but also the variability of the EoP of the user’s biome-chanics [16].”
BackgroundSelf-citationPaik, P., Thudi, S., & Atashzar, S. F. (2022) · IEEE Transactions on Robotics · doi:10.1109/tro.2022.3197932 · Cited by 17
“telerobotic architecture proposed by our team before [35].”
BackgroundMethodSelf-citationEnergetic Passivity Decoding of Human Hip Joint for Physical Human-Robot Interaction
Atashzar, S. F., Huang, H.-Y., Duca, F. D., Burdet, E., & Farina, D. (2020) · IEEE Robotics and Automation Letters · doi:10.1109/lra.2020.3010459 · Cited by 15
“As a result, implementing classical derivations of controllers, such as TDPA, for assistive therapies will result in excessively dampening of the assistance and compensating for the assistive power generated by the robot [33], [34], [35].”
BackgroundSelf-citationThudi, S., & Atashzar, S. F. (2021) · IEEE Robotics and Automation Letters · doi:10.1109/lra.2021.3064204 · Cited by 13
“• Case 1: Reflected Impedance: The reflected impedance represents the extent of the assistive/resistive therapy delivered from the therapist (environment) to the patient, in the telerobotic system [2].”
BackgroundSelf-citationHernández-Ortiz, Ó., & Arteaga, M. A. (2020) · Control Engineering Practice · doi:10.1016/j.conengprac.2020.104564 · Cited by 10
Evolving control of human-exoskeleton system using Gaussian process with local model
Yang, J., & Peng, C. (2020) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2019.101844 · Cited by 10
Avraham, C., & Nisky, I. (2020) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-020-0649-y · Cited by 10
S 2 -RTPIC: A State-Switching Remote Therapist Patient Interaction Control for Telerehabilitation
Yang, Z., Guo, S., Ren, L., An, R., Liu, Y., & Kawanishi, M. (2024) · IEEE Transactions on Industrial Informatics · doi:10.1109/tii.2024.3452244 · Cited by 9
Stabilization of Robot-Environment Interaction Through Generalized Scattering Techniques
Usova, A. A., Pachkouski, K. A., Polushin, I. G., & Patel, R. V. (2021) · IEEE Transactions on Robotics · doi:10.1109/tro.2021.3107231 · Cited by 9
Self-citationUpper-limb Geometric MyoPassivity Map for Physical Human-Robot Interaction
Zhou, X., Paik, P., & Atashzar, S. F. (2023) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/icra48891.2023.10161188 · Cited by 10
“shown if the EoP of the user’s upper-limb biomechanics is greater than the SoP of the force field injected by the robot into the interconnection, the overall pHRI system will remain L2 stable [10].”
BackgroundSelf-citationPassivity-based control of nonlinear teleoperation systems with non-passive interaction forces
Bavili, R. E., Akbari, A., & Esfanjani, R. M. (2020) · Intelligent Service Robotics · doi:10.1007/s11370-020-00327-6 · Cited by 7
A Wave Variable Approach With Multiple Channel Architecture for Teleoperated System
Luo, J., Liu, C., Wang, N., & Yang, C. (2019) · IEEE Access · doi:10.1109/access.2019.2945674 · Cited by 6
“A bilateral teleoperated architecture with a small gain method was developed to guarantee the safety of human-robot interaction in the presence of without passivity [23].”
MethodSensorimotor Skill Communication: A Literature Review
Babushkin, V., Jamil, M. H., Park, W., & Eid, M. A. (2021) · IEEE Access · doi:10.1109/access.2021.3081449 · Cited by 7
“Haptics-enabled tele-rehabilitation systems provide a bi-directional haptic interaction in a virtual environment that allows the therapist to remotely guide the patient by applying nonpassive nonlinear assistive/resistive forces in response to their movements [27], [28].”
BackgroundTransparent master-slave teleoperation without force nor velocity measurements
Gutiérrez–Giles, A., Arteaga, M. A., & Rodríguez-Ángeles, A. (2019) · European Control Conference (ECC) · doi:10.23919/ecc.2019.8796143 · Cited by 5
Wang, K., Wang, Y., & Yin, P.-C. (2021) · Proceedings of the Institution of Mechanical Engineers Part C Journal of Mechanical Engineering Science · doi:10.1177/09544062211020344 · Cited by 5
“In order to improve the training of the muscle strength of the inner thigh muscle group of patients and meet the needs of the rehabilitation training track, Ataszsar proposed a bilateral remote control architecture for rehabilitation, which enables rehabilitation physicians to provide non-linear assistance/ resistance…”
BackgroundInterday Reliability of Upper-limb Geometric MyoPassivity Map for Physical Human-Robot Interaction
Zhou, X., Paik, P., O’Keeffe, R., & Atashzar, S. F. (2023) · IEEE Transactions on Haptics · doi:10.1109/toh.2023.3277453 · Cited by 7
“A widely-used and efficient method for handling uncertain environmental dynamics and variable delays are the Time-domain Passivity Approach (TDPA) [11], [12], [13], [14], [15], [16], [17].”
MethodSelf-citationA self-tuning dual impedance control architecture for collaborative haptic training
Motaharifar, M., Hashtrudi-Zaad, K., Mohammadi, S.-F., Lashay, A., & Taghirad, H. D. (2024) · Mechatronics · doi:10.1016/j.mechatronics.2024.103205 · Cited by 5
DBR-TILT: A Novel Direct Biomechanics Reflecting Therapist-in-the-Loop Telerehabilitation System
Yang, Z., Guo, S., Ren, L., Qian, Z., An, R., Liu, Y., & Kawanishi, M. (2025) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2025.3627075 · Cited by 4
“Moreover, a small-gain-theory-based control approach was developed for further dealing with the nonpassive behaviors of therapists and patients to improve the conservation of the stabilizer [11].”
Paik, P., Zhou, X., & Atashzar, S. F. (2025) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2025.3575999 · Cited by 5
“…of new algorithms which can guarantee the stability of the system while maximizing the transparency when relaxing classical assumptions (such as passivity of the environment) which is voided when two humans interact over a telerobotic system (more details can be seen in [5], [7], [8], and [11]).”
InfluentialSelf-citationMartinez, C. M., Fong, J., Atashzar, S. F., & Tavakoli, M. (2019) · IEEE Global Conference on Signal and Information Processing · doi:10.1109/globalsip45357.2019.8969143 · Cited by 3
“In order to directly combine the therapists skills and the characteristics of a robotic system, telerobotic rehabilitation systems have been developed, using which the therapist can generate motion command through a robotic console, while perceiving the reactions of the patient, and the patient would receive the motio…”
BackgroundSelf-citationTime-Domain Passivity-based Controller with an Optimal Two-channel Lawrence Telerobotic Architecture
Feizi, N., Thudi, S., Patel, R. V., & Atashzar, S. F. (2021) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/icra48506.2021.9561930 · Cited by 3
“In this regard, a wide range of stabilizers has been proposed for teleoperation, including wave variables [5]–[7], time-domain passivity control [2], [4], [8]–[17], and small-gain controllers [3], [18], [19].”
BackgroundSelf-citationOn Stabilizing Communication Law for Bilateral Teleoperations
Tho, H. D., & Miyoshi, T. (2023) · IEEE Transactions on Automatic Control · doi:10.1109/tac.2023.3289925 · Cited by 2
“Although some existing methods based on the small-gain theorem and wave filters can overcome this dilemma (see [9] and [10]), they tend to be heuristic and their extensions to nonlinear teleoperations are not plausible.”
MethodOn Stabilizing Communication Law for Bilateral Force-reflecting Teleoperation Systems
Tho, H. D., & Miyoshi, T. (2022) · IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS) · doi:10.1109/iros47612.2022.9981557 · Cited by 2
“Although some existing methods based on the small-gain theorem and wave filters can overcome this dilemma (see [12], [13]), they tend to be heuristic and their extensions to nonlinear teleoperations are not plausible.”
MethodNajafabadi, A. M., Ataei, M., & Motaharifar, M. (2022) · RSI International Conference on Robotics and Mechatronics (ICRoM) · doi:10.1109/icrom57054.2022.10025246 · Cited by 2
“These systems are used in various tasks such as haptic surgical training [2] and tele-rehabilitation [3].”
MethodYang, Z., & Guo, S. (2023) · IEEE International Conference on Mechatronics and Automation (ICMA) · doi:10.1109/icma57826.2023.10216104 · Cited by 2
“Teleoperation technology is also widely applied to medical scenarios, such as the telesurgery robotic system [13] [14] [15] and the telerehabilitation robotic system [16] [17] [18] [19].”
BackgroundOliver, S., Paik, P., Zhou, X., & Atashzar, S. F. (2023) · IEEE Robotics and Automation Letters · doi:10.1109/lra.2023.3313489 · Cited by 4
Self-citationNo distance between disabled people and rehabilitation engineer in high-tech era
Gun, L. (2017) · Surgery and Rehabilitation · doi:10.15761/srj.1000118 · Cited by 1
Human-Robot Interaction: Mapping Literature Review and Network Analysis
Oberhofer, V., Seeber, I., & Maier, R. (2023) · Hawaii International Conference on System Sciences (HICSS) · doi:10.24251/hicss.2023.061 · Cited by 1
Wang, C., Liu, Y., Sun, C., Li, P., Chen, Y.-F., Dong, M., Li, Z., Liu, L., & Zhang, M. (2026) · IEEE Transactions on Robotics · doi:10.1109/tro.2026.3651680 · Cited by 1
“Furthermore, research in bilateral telerobotic rehabilitation has verified that assistance from the therapists can lead to a nonpassive interaction environment for the patient [20], [22], [39].”
Control strategies for robot‐assisted telerehabilitation under communication delay: A survey
Ngo, V., & Liu, Y.-C. (2026) · Asian Journal of Control · doi:10.1002/asjc.70176 · Cited by 1
Zhou, X., Paik, P., & Atashzar, S. F. (2023) · IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS) · doi:10.1109/iros55552.2023.10341393 · Cited by 1
“Therefore, numerous approaches have been proposed to address this stability issues [7]–[11].”
BackgroundSelf-citationA Robust Controller with Online Authority Transformation for Dual User Haptic Training System
Motaharifar, M., Taghirad, H. D., & Mohammadi, S.-F. (2020) · Journal of Control · doi:10.29252/joc.14.2.63
Zhou, X., Paik, P., & Atashzar, S. F. (2024) · Proceedings of the ... American Control Conference/Proceedings of the American Control Conference · doi:10.23919/acc60939.2024.10644460 · Cited by 1
“This design modifies the conventional Lawrence’s four-channel architecture (details can be found in [6]).”
BackgroundMethodSelf-citationKarkevandi, J. B., Ataei, M., Motaharifar, M., Shanahan, D., & Montazeri, A. (2025) · IFAC-PapersOnLine · doi:10.1016/j.ifacol.2025.09.119
Metadata
- Authors
- Atashzar, S. F., Polushin, I. G., & Patel, R. V.
- Affiliations
- Western University (CA)
- Venue
- IEEE Transactions on Robotics
- Published
- 2017-02
- Volume
- 33
- Issue
- 1
- Pages
- 49-66
- ISSN
- 1552-3098 (ISSN-L)
- 1941-0468
- OpenAlex
- W2560296492
- Cited by
- 57
- References
- 35
- Citations by year
- 2026: 2 · 2025: 3 · 2024: 4 · 2023: 8 · 2022: 9 · 2021: 8 · 2020: 10 · 2019: 4 · 2018: 5 · 2017: 4
- FWCI
- 3.85
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- IEEE Transactions on Robotics (publishedVersion)
- Funders
- Collaborative Health Research Projects (316170)
- AGE-WELL Network of Centres of Excellencey (2015-WP5.3)
- Topics
- Physical Sciences › Engineering › Mechanical Engineering › Teleoperation and Haptic Systems
- Physical Sciences › Engineering › Biomedical Engineering › Prosthetics and Rehabilitation Robotics
- Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Telemedicine and Telehealth Implementation
- Keywords
- bilateral teleoperation, haptic feedback, human-robot interaction safety, stability analysis, controller synthesis, time-varying delays, therapist supervision
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.