CoChat

A grasp-based passivity signature for haptics-enabled human-robot interaction: Application to design of a new safety mechanism for robotic rehabilitation

Atashzar, Seyed Farokh, Shahbazi, Mahya, Tavakoli, Mahdi, Patel, Rajni V · 2017 · The International Journal of Robotics Research

The DOI matches its Crossref record; 61 of the 61 references it cites were found in a registry or an index.

Abstract

In this paper, the biomechanical capability of the human upper limb in absorbing physical interaction energy during human-robot interaction is analyzed. The outcome is a graphical map that can quantitatively correlate the extent of the grasp pressure and the geometry of interaction to the extent of hand passivity. For this purpose, a user study has been conducted for 11 healthy human subjects to characterize the energy absorption capability in their arm and wrist. The above correlation is statistically validated. The identified user-specific grasp-based passivity signature map can be used as a graphical tool to assess the biomechanical capabilities of the upper limb in absorbing interaction energy. In this paper, the proposed grasp-based passivity signature map is utilized in the design of a new stabilizer for haptic systems, that takes into account the variation in energy absorption during haptic task execution. The goal is to optimize the haptic system fidelity while guaranteeing human-robot interaction stability despite the potential existence of delays and a non-passive environment. The controller is termed grasp-based passivity signature map stabilizer. If the user provides minimum to no energy absorption during the interaction, the controller makes the force reflection gate tight to guarantee stability. However, when the user demonstrates high capability in absorbing interaction energy, the controller allows the forces to be reflected. The grasp-based passivity signature map stabilizer is an alternative for both conventional stabilizers of haptic/telerobotic systems and fixed conservative force limits in rehabilitation systems where patient-robot interaction safety is a crucial requirement. This provides the practical motivation for this work. Experimental results are presented.

Overview

Integrity signals

Registry

Crossref · 10.1177/0278364916689139

Cites

61 of 61 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 61 references

Research works printed but not linked: 2

  1. Hommel G, 2009, Deutsches Ärzteblatt International, 106, 335
  2. Khalil HK, 2002, Nonlinear Systems, 3

Cited by

See all 43

Metadata

Authors
Atashzar, S. F., Shahbazi, M., Tavakoli, M., & Patel, R. V.
Affiliations
  • Western University (CA)
  • University of Alberta (CA)
Corresponding author
Atashzar, Seyed Farokh
Venue
The International Journal of Robotics Research
Published
2017-04-04
Volume
36
Issue
5-7
Pages
778-799
ISSN
  • 0278-3649 (ISSN-L)
  • 1741-3176
OpenAlex
W2604635497
Cited by
41
References
61
Citations by year
2026: 1 · 2025: 1 · 2024: 6 · 2023: 8 · 2022: 3 · 2021: 5 · 2020: 11 · 2019: 3 · 2018: 2 · 2017: 1
FWCI
3.61
Type
journal article
Language
en
Open access
closed
Licence
journals.sagepub.com/page/policies/text-and-data-mining-license (tdm)
Locations
The International Journal of Robotics Research (publishedVersion)
Funders
  • Quanser Inc.
  • Natural Sciences and Engineering Research Council (NSERC) of Canada and Canadian Institutes of Health Research (CIHR) under a Collaborative Health Research Projects (CHRP) Grant (316170)
  • Canada Foundation for Innovation (28241)
  • NSERC Discovery Grant (RGPIN 1345)
  • AGE-WELL Network of Centres of Excellence Grant (AW CRP 2015-WP5.3)
  • Alberta Innovation and Advanced Education Ministry under Small Equipment (RCP-12-021)
Topics
  • Physical Sciences › Engineering › Mechanical Engineering › Teleoperation and Haptic Systems
  • Physical Sciences › Engineering › Biomedical Engineering › Prosthetics and Rehabilitation Robotics
  • Physical Sciences › Engineering › Control and Systems Engineering › Robot Manipulation and Learning
Keywords
human-robot interaction, haptic devices, rehabilitation robotics, energy absorption, upper limb biomechanics, force reflection, interaction stability

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A grasp-based passivity signature for haptics-enabled human-robot interaction: Application to design of a new safety mechanism for robotic rehabilitation. https://app.cochat.ai/papers/10.1177/0278364916689139
The paper
Atashzar, S. F., Shahbazi, M., Tavakoli, M., & Patel, R. V. (2017). A grasp-based passivity signature for haptics-enabled human-robot interaction: Application to design of a new safety mechanism for robotic rehabilitation. The International Journal of Robotics Research. https://doi.org/10.1177/0278364916689139

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.