The DOI matches its Crossref record; 36 of the 36 references it cites were found in a registry or an index.
A Small-Gain Approach for Nonpassive Bilateral Telerobotic Rehabilitation: Stability Analysis and Controller Synthesis
Abstract
In this paper, the design of a novel bilateral telerobotic architecture for rehabilitation purposes is proposed and the related feasibility, stability, and control challenges are studied. The objective is to incorporate the supervision of a local/remote human physiotherapist into haptics-enabled rehabilitation systems and allow the therapist to provide nonpassive nonlinear assistive/resistive forces in response to the patient's movements. This can address a challenge of conventional software-based rehabilitation systems, i.e., limited capability in adjusting the therapy. To guarantee human-robot interaction safety, a new design framework and a stabilizing controller are developed based on the small-gain approach. System stability and transparency are analyzed in the presence of the nonpassive, nonlinear, and nonautonomous behavior of the terminals (the therapist and the patient) and time-varying delays for the case of remote and cloud-based therapy. Several practical considerations have been taken into account to match the clinical needs and minimize the implementation cost. Simulation studies, practical implementation, and experimental evaluations are presented.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“It is worth noting that phase lag (even in the order of 10 ms) can easily make a high-gain rehabilitation robot unstable which can sacrifice safety13,56–59.”
From PHTNet: Characterization and Deep Mining of Involuntary Pathological Hand Tremor using Recurrent Neural Network Models (2020) · cites this paper as [56]
Citations
Cites
Stability and transparency in bilateral teleoperation
Lawrence, D. A. (1993) · IEEE Transactions on Robotics and Automation · doi:10.1109/70.258054 · Cited by 2,061
Linear controller design: limits of performance
Boyd, S., & Barratt, C. H. (1991) · Prentice-Hall, Inc eBooks · Cited by 1,196
Review of control strategies for robotic movement training after neurologic injury
Marchal-Crespo, L., & Reinkensmeyer, D. J. (2009) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-6-20 · Cited by 1,182
Input to State Stability: Basic Concepts and Results
Sontag, E. D. (2008) · Lecture Notes in Mathematics · doi:10.1007/978-3-540-77653-6_3 · Cited by 1,181 · cited 1×
“fer matrix is proper; in this case, the peak gain of a system is equal to its IOS gain [28].”
BackgroundTime-domain passivity control of haptic interfaces
Hannaford, B., & Ryu, J.-H. (2002) · IEEE Transactions on Robotics and Automation · doi:10.1109/70.988969 · Cited by 767
Rehabilitation Robotics: Performance-Based Progressive Robot-Assisted Therapy
Krebs, H. I., Palazzolo, J. J., Dipietro, L., Ferraro, M., Krol, J., Rannekleiv, K., Volpe, B. T., & Hogan, N. (2003) · Autonomous Robots · doi:10.1023/a:1024494031121 · Cited by 714 · cited 1×
“of impairment, body dynamics, and needs for rehabilitation [11]–[13].”
BackgroundDissipative systems analysis and control theory and applications
Lozano, R. (2000) · Cited by 647
Stable haptic interaction with virtual environments
Adams, R. J., & Hannaford, B. (1999) · IEEE Transactions on Robotics and Automation · doi:10.1109/70.768179 · Cited by 646 · cited 1×
“An example can be the definition of Z width developed in the literature for linear haptic rendering systems [31].”
BackgroundEpidemiology and the Global Burden of Stroke
Mukherjee, D., & Patil, C. G. (2011) · World Neurosurgery · doi:10.1016/j.wneu.2011.07.023 · Cited by 644 · cited 1×
“It is anticipated that the population of people suffering a stroke worldwide each year will reach 23 million by 2030 [3].”
BackgroundDissipative Systems Analysis and Control
Lozano, R., Brogliato, B., Egeland, O., & Maschke, B. (2000) · Communications and Control Engineering · doi:10.1007/978-1-4471-3668-2 · Cited by 554
Robot-Aided Neurorehabilitation: A Robot for Wrist Rehabilitation
Krebs, H. I., Volpe, B. T., Williams, D., Celestino, J., Charles, S. K., Lynch, D., & Hogan, N. (2007) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2007.903899 · Cited by 553 · cited 1×
“PVT is an interactive virtual-reality-based environment that can provide the patient with assistive and resistive therapeutic forces during various tasks [2], [9].”
BackgroundConnections between Razumikhin-type theorems and the ISS nonlinear small gain theorem
Teel, A. R. (1998) · IEEE Transactions on Automatic Control · doi:10.1109/9.701099 · Cited by 451
Rehabilitation robotics: pilot trial of a spatial extension for MIT-Manus
Krebs, H. I., Ferraro, M., Buerger, S. P., Newbery, M. J., Makiyama, A., Sandmann, M., Lynch, D., Volpe, B. T., & Hogan, N. (2004) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-1-5 · Cited by 445 · cited 1×
“Commercially available robotic rehabilitation systems use a haptics-enabled software-based environment equipped with a programmable virtual therapist (PVT) [2], [5], [7], [8].”
BackgroundRobotic techniques for upper limb evaluation and rehabilitation of stroke patients
Colombo, R., Pisano, F., Micera, S., Mazzone, A., Delconte, C., Carrozza, M. C., Dario, P., & Minuco, G. (2005) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2005.848352 · Cited by 399 · cited 4×
“There are significant advantages with the use of haptics-enabled robotic rehabilitation systems, such as accelerating recovery of disabled patients [2], [4] and helping therapists in quantifying the severity of movement disorders [5], [6].”
BackgroundMethodInfluentialMotions or muscles? Some behavioral factors underlying robotic assistance of motor recovery
Hogan, N., Krebs, H. I., Rohrer, B., Palazzolo, J. J., Dipietro, L., Fasoli, S. E., Stein, J., Hughs, R., Frontera, W. R., Lynch, D., et al. (2006) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.2005.06.0103 · Cited by 374 · cited 1×
“As a result, improved motor performance has been reported using adaptive virtual therapy techniques [14], [15].”
BackgroundHashtrudi-Zaad, K., & Salcudean, S. E. (2001) · The International Journal of Robotics Research · doi:10.1177/02783640122067471 · Cited by 365 · cited 3×
“This force cancelation is similar to ELFC architecture [18], [19].”
BackgroundResultA paradigm shift for rehabilitation robotics
Krebs, H., Dipietro, L., Levy-Tzedek, S., Fasoli, S., Rykman-Berland, A., Zipse, J., Fawcett, J., Stein, J., Poizner, H., Lo, A., et al. (2008) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/memb.2008.919498 · Cited by 162
High-Fidelity Bilateral Teleoperation Systems and the Effect of Multimodal Haptics
Tavakoli, M., Aziminejad, A., Patel, R. V., & Moallem, M. (2007) · IEEE Transactions on Systems Man and Cybernetics Part B (Cybernetics) · doi:10.1109/tsmcb.2007.903700 · Cited by 152 · cited 1×
“ideal transparency corresponds to the following formula [24]:”
BackgroundSelf-citationTherapeutic Robotics: A Technology Push
Krebs, H. I., & Hogan, N. (2006) · Proceedings of the IEEE · doi:10.1109/jproc.2006.880721 · Cited by 138 · cited 9×
“One of the problems of PVT-based systems is how to modify the assistive/resistive exercises.”
BackgroundMethodInfluentialRen, Y., Kang, S. H., Park, H., Wu, Y., & Zhang, L. (2012) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2012.2225073 · Cited by 128 · cited 2×
“There are significant advantages with the use of haptics-enabled robotic rehabilitation systems, such as accelerating recovery of disabled patients [2], [4] and helping therapists in quantifying the severity of movement disorders [5], [6].”
BackgroundSelf-adaptive robot training of stroke survivors for continuous tracking movements
Vergaro, E., Casadio, M., Squeri, V., Giannoni, P., Morasso, P., & Sanguineti, V. (2010) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-7-13 · Cited by 114
Dipietro, L., Krebs, H. I., Volpe, B. T., Stein, J. M., Bever, C. T., Mernoff, S. T., Fasoli, S. E., & Hogan, N. (2011) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2011.2175008 · Cited by 112 · cited 1×
“As a result, improved motor performance has been reported using adaptive virtual therapy techniques [14], [15].”
BackgroundModeling the human hand as it interacts with a telemanipulation system
Speich, J. E., Shao, L., & Goldfarb, M. T. (2005) · Mechatronics · doi:10.1016/j.mechatronics.2005.06.001 · Cited by 112
A control scheme for stable force-reflecting teleoperation over IP networks
Polushin, I. G., Liu, P. X., & Lung, C. (2006) · IEEE Transactions on Systems Man and Cybernetics Part B (Cybernetics) · doi:10.1109/tsmcb.2005.861878 · Cited by 89
Self-citationAdaptive Virtual Reality Games for Rehabilitation of Motor Disorders
Ma, M., McNeill, M. D. J., Charles, D. K., McDonough, S., Crosbie, J., Oliver, L. M., & McGoldrick, C. (2007) · Lecture notes in computer science · doi:10.1007/978-3-540-73281-5_74 · Cited by 83
A small gain framework for networked cooperative force-reflecting teleoperation
Polushin, I. G., Dashkovskiy, S. N., Takhmar, A., & Patel, R. V. (2012) · Automatica · doi:10.1016/j.automatica.2012.11.001 · Cited by 77 · cited 4×
“Definition 1: [21] System (44) is said to be WIOS with linear IOS gains γ ≥ 0, i = 1, .”
BackgroundSelf-citationEstimating Physical Assistance Need Using a Musculoskeletal Model
Carmichael, M. G., & Liu, D. (2013) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2013.2244889 · Cited by 65 · cited 1×
“of impairment, body dynamics, and needs for rehabilitation [11]–[13].”
BackgroundA Multichannel IOS Small Gain Theorem for Systems With Multiple Time-Varying Communication Delays
Polushin, I. G., Marquez, H. J., Tayebi, A., & Liu, P. X. (2009) · IEEE Transactions on Automatic Control · doi:10.1109/tac.2008.2009582 · Cited by 63 · cited 1×
“The fulfillment of this assumption does not depend on the characteristics of the channel, such as bandwidth and information loss percentage (see [21] and [22]).”
BackgroundSelf-citationAugmented Dynamics and Motor Exploration as Training for Stroke
Huang, F. C., & Patton, J. L. (2012) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2012.2192116 · Cited by 52 · cited 1×
“of robotic assistive rehabilitation technique can be found in [35].”
BackgroundNetworked teleoperation with non-passive environment: Application to tele-rehabilitation
Atashzar, S. F., Polushin, I. G., & Patel, R. V. (2012) · IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS) · doi:10.1109/iros.2012.6386152 · Cited by 49 · cited 9×
“been conducted here upon consultation with clinicians, while [1] does not contain any experimental/implementation result.”
BackgroundMethodSelf-citationGlobal transparency analysis of the Lawrence teleoperator architecture
Nærum, E., & Hannaford, B. (2009) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/robot.2009.5152791 · Cited by 38 · cited 1×
“This method is a modified version of the one proposed in [25].”
MethodBilateral Teleoperation: Quantifying the Requirements for and Restrictions of Ideal Transparency
Willaert, B., Reynaerts, D., BRUSSEL, H. V., & Poorten, E. V. (2013) · IEEE Transactions on Control Systems Technology · doi:10.1109/tcst.2013.2251345 · Cited by 31 · cited 2×
“This force cancelation is similar to ELFC architecture [18], [19].”
BackgroundResultTelepresence Index for Bilateral Teleoperations
Chang, P. H., & Kim, J. (2011) · IEEE Transactions on Systems Man and Cybernetics Part B (Cybernetics) · doi:10.1109/tsmcb.2011.2160849 · Cited by 21 · cited 1×
“Considering definition of hybrid matrix H(s) [23] as [ Fp(s) −Vth(s) ]”
BackgroundExpanding Tele-rehabilitation of Stroke Through In-home Robot-assisted Therapy
Wu, C. B. D. (2013) · International Journal of Physical Medicine & Rehabilitation · doi:10.4172/2329-9096.1000184 · Cited by 21
Parameter-space transparency analysis of teleoperation systems
Schauß, T., & Peer, A. (2012) · IEEE Haptics Symposium · doi:10.1109/haptic.2012.6183778 · Cited by 9
Parameter-Space Transparency Analysis of Teleoperation Systems
Schauß, T. P. (n.d.) · mediaTUM – the media and publications repository of the Technical University Munich (Technical University Munich) · Cited by 5
Cited by
Haptic Feedback and Force-Based Teleoperation in Surgical Robotics
Patel, R. V., Atashzar, S. F., & Tavakoli, M. (2022) · Proceedings of the IEEE · doi:10.1109/jproc.2022.3180052 · Cited by 200
“Using small gain control, the aforementioned assumptions are relaxed, and variable time delays are also considered to propose several new categories of stabilizers that guarantee system stability while reducing deterioration in transparency by decreasing the conservatism of the system [92]–[94], [127], [129], [130], […”
BackgroundInfluentialSelf-citationRobotics in Healthcare: A Survey
Silvera‐Tawil, D. (2024) · SN Computer Science · doi:10.1007/s42979-023-02551-0 · Cited by 183
“Telerobots can also support clinicians with other tasks, such as the remote evaluation and rehabilitation of upper-limb function [150, 151].”
Atashzar, S. F., Carriere, J., & Tavakoli, M. (2021) · Frontiers in Robotics and AI · doi:10.3389/frobt.2021.610529 · Cited by 75
“(2015); Atashzar et al. (2016b); Atashzar et al. (2017b); Atashzar et al. (2020)).”
BackgroundInfluentialSelf-citationHuman Lower Limb Motion Intention Recognition for Exoskeletons: A Review
Li, L., Cao, G., Liang, H., Zhang, Y.-P., & Cui, F. (2023) · IEEE Sensors Journal · doi:10.1109/jsen.2023.3328615 · Cited by 70
“HMIR not only involves signals from CNS and musculoskeletal dynamics but also concerns the past and current motion states and trajectories [233].”
BackgroundReview of Advanced Medical Telerobots
Mehrdad, S., Liu, F., Pham, M. T., Lelevé, A., & Atashzar, S. F. (2020) · Applied Sciences · doi:10.3390/app11010209 · Cited by 66
“Thus with the use of advanced technology, including ultra-fast communication, advanced instrumentation, and algorithmic stabilizers [7,64,82,85,150,166,180,181,184], it can be envisioned that the next generation of telerobotic surgical systems is equipped with means of high-fidelity haptics…”
InfluentialSelf-citation
Metadata
- Authors
- Atashzar, S. F., Polushin, I. G., & Patel, R. V.
- Affiliations
- Western University (CA)
- Venue
- IEEE Transactions on Robotics
- Published
- 2017-02
- Volume
- 33
- Issue
- 1
- Pages
- 49-66
- ISSN
- 1552-3098 (ISSN-L)
- 1941-0468
- OpenAlex
- W2560296492
- Cited by
- 57
- References
- 35
- Citations by year
- 2026: 2 · 2025: 3 · 2024: 4 · 2023: 8 · 2022: 9 · 2021: 8 · 2020: 10 · 2019: 4 · 2018: 5 · 2017: 4
- FWCI
- 3.85
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- IEEE Transactions on Robotics (publishedVersion)
- Funders
- Collaborative Health Research Projects (316170)
- AGE-WELL Network of Centres of Excellencey (2015-WP5.3)
- Topics
- Physical Sciences › Engineering › Mechanical Engineering › Teleoperation and Haptic Systems
- Physical Sciences › Engineering › Biomedical Engineering › Prosthetics and Rehabilitation Robotics
- Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Telemedicine and Telehealth Implementation
- Keywords
- bilateral teleoperation, haptic feedback, human-robot interaction safety, stability analysis, controller synthesis, time-varying delays, therapist supervision
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).