The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Pushing the Limits in Time-of-Flight PET Imaging
Open accessAbstract
There is an increasing demand for high sensitivity multiparametric medical imaging approaches. High precision time-of-flight positron emission tomography (TOFPET) scanners have a very high potential in this context, providing an improvement in the signal-to-noise ratio of the reconstructed image and the possibility to further increase the already very high sensitivity (at the pico-molar level) of PET scanners. If the present state-of-the art coincidence time resolution of about 500 ps can be improved, it will open the way in particular to a significant reduction of the dose injected to the patient, and consequently, to the possibility to extend the use of PET scans to new categories of patients. This paper will describe the systematic approach followed by a number of researchers worldwide to push the limits of TOFPET imaging to the sub-100 ps level. It will be shown that the possibility to reach 10 ps, although extremely challenging, is not limited by physical barriers and that a number of disruptive technologies are presently being investigated at the level of all the components of the detection chain to gain at least a factor of 10 as compared to the present state-of-the-art.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Inhibited Spontaneous Emission in Solid-State Physics and Electronics
Yablonovitch, E. (1987) · Physical Review Letters · doi:10.1103/physrevlett.58.2059 · Cited by 14,067
Strong localization of photons in certain disordered dielectric superlattices
John, S. (1987) · Physical Review Letters · doi:10.1103/physrevlett.58.2486 · Cited by 10,029
Continuous-wave biexciton lasing at room temperature using solution-processed quantum wells
Grim, J. Q., Christodoulou, S., Di Stasio, F., Krahne, R., Cingolani, R., Manna, L., & Moreels, I. (2014) · Nature Nanotechnology · doi:10.1038/nnano.2014.213 · Cited by 532
The digital silicon photomultiplier — Principle of operation and intrinsic detector performance
Frach, T., Prescher, G., Degenhardt, C., de Gruyter, R., Schmitz, A., & Ballizany, R. (2009) · 2009 IEEE Nuclear Science Symposium Conference Record (NSS/MIC) · doi:10.1109/nssmic.2009.5402143 · Cited by 317
History and future technical innovation in positron emission tomography
Jones, T., & Townsend, D. (2017) · Journal of Medical Imaging · doi:10.1117/1.jmi.4.1.011013 · Cited by 303
Total-body imaging: Transforming the role of positron emission tomography
Cherry, S. R., Badawi, R. D., Karp, J. S., Moses, W. W., Price, P., & Jones, T. (2017) · Science Translational Medicine · doi:10.1126/scitranslmed.aaf6169 · Cited by 251
Studies of a Next-Generation Silicon-Photomultiplier–Based Time-of-Flight PET/CT System
Hsu, D. F. C., Ilan, E., Peterson, W. T., Uribe, J., Lubberink, M., & Levin, C. S. (2017) · Journal of Nuclear Medicine · doi:10.2967/jnumed.117.189514 · Cited by 241
Gundacker, S., Auffray, E., Pauwels, K., & Lecoq, P. (2016) · Physics in Medicine and Biology · doi:10.1088/0031-9155/61/7/2802 · Cited by 173
Self-citationGundacker, S., Acerbi, F., Auffray, E., Ferri, A., Gola, A. G., Nemallapudi, M. V., Paternoster, G., Piemonte, C., & Lecoq, P. R. (2016) · Journal of Instrumentation · doi:10.1088/1748-0221/11/08/p08008 · Cited by 155
Self-citationCan Transient Phenomena Help Improving Time Resolution in Scintillators?
Lecoq, P. R., Korzhik, M., & Vasiliev, A. (2013) · IEEE Transactions on Nuclear Science · doi:10.1109/tns.2013.2282232 · Cited by 92
Self-citation
Cited by
State of the art in total body PET
Vandenberghe, S., Moskal, P., & Karp, J. S. (2020) · EJNMMI Physics · doi:10.1186/s40658-020-00290-2 · Cited by 390
Efficient, fast and reabsorption-free perovskite nanocrystal-based sensitized plastic scintillators
Gandini, M., Villa, I., Beretta, M., Gotti, C., Imran, M., Carulli, F., Fantuzzi, E., Sassi, M., Zaffalon, M., Brofferio, C., et al. (2020) · Nature Nanotechnology · doi:10.1038/s41565-020-0683-8 · Cited by 389
Esmaeil Zadeh, I., Chang, J., Los, J. W. N., Gyger, S., Elshaari, A. W., Steinhauer, S., Dorenbos, S. N., & Zwiller, V. (2021) · Applied Physics Letters · doi:10.1063/5.0045990 · Cited by 331
Gundacker, S., Martinez Turtos, R., Kratochwil, N., Pots, R. H., Paganoni, M., Lecoq, P., & Auffray, E. (2020) · Physics in Medicine & Biology · doi:10.1088/1361-6560/ab63b4 · Cited by 265
Self-citationRoadmap toward the 10 ps time-of-flight PET challenge
Lecoq, P., Morel, C., Prior, J. O., Visvikis, D., Gundacker, S., Auffray, E., Križan, P., Turtos, R. M., Thers, D., Charbon, E., et al. (2020) · Physics in Medicine & Biology · doi:10.1088/1361-6560/ab9500 · Cited by 258
Self-citation
Metadata
- Authors
- Lecoq, P.
- Venue
- IEEE Transactions on Radiation and Plasma Medical Sciences
- Published
- 2017-11
- Volume
- 1
- Issue
- 6
- Pages
- 473-485
- ISSN
- 2469-7303 (ISSN-L)
- 2469-7311
- OpenAlex
- W2760029687
- Cited by
- 302
- References
- 11
- FWCI
- 27.95
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Pushing the Limits in Time-of-Flight PET Imaging. https://app.cochat.ai/papers/10.1109/trpms.2017.2756674
- The paper
- Lecoq, P. (2017). Pushing the Limits in Time-of-Flight PET Imaging. IEEE Transactions on Radiation and Plasma Medical Sciences. https://doi.org/10.1109/trpms.2017.2756674
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.