A Differential Sequence Component Protection Scheme for Microgrids With Inverter-Based Distributed Generators
The DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.
Abstract
The protection of a microgrid containing inverter- based distributed generators (IBDGs) presents several problems if traditional techniques which rely on the current (fuses and overcurrent relays) are used. A possible solution to these problems is the use of a new type of the relay which takes advantage of the enhanced processing techniques and communication infrastructure, both of which are recently becoming available for power networks application. This paper proposes a new communication-based protection scheme for isolated microgrids where a data mining approach is used to identify the relay settings and parameters. A feature selection technique is implemented to help identify the most relevant electrical features required for the fault detection and to establish the best communication strategy to use between relays. The proposed approach is tested using a MATLAB simulation of a facility scale isolated microgrid embedded with IBDGs. The results show that a differential protection scheme that relies on symmetrical components is the most effective strategy for protecting microgrids with IBDGs.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Breiman, L. (2001) · Machine Learning · doi:10.1023/a:1010933404324 · Cited by 133,538
Modeling, Analysis and Testing of Autonomous Operation of an Inverter-Based Microgrid
Pogaku, N., Prodanovic, M., & Green, T. C. (2007) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2006.890003 · Cited by 3,018
Lasseter, R. H. (2003) · 2002 IEEE Power Engineering Society Winter Meeting. Conference Proceedings (Cat. No.02CH37309) · doi:10.1109/pesw.2002.985003 · Cited by 1,997
Computational Methods of Feature Selection
(2007) · Chapman & Hall/CRC eBooks · doi:10.1201/9781584888796 · Cited by 1,271
Jenkins, N. (2000) · Institution of Engineering and Technology eBooks · doi:10.1049/pbpo031e · Cited by 556
Microgrid Protection Using Communication-Assisted Digital Relays
Sortomme, E., Venkata, S. S., & Mitra, J. (2010) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2009.2035810 · Cited by 537
CERTS Microgrid Laboratory Test Bed
Lasseter, R. H., Eto, J. H., Schenkman, B., Stevens, J., Vollkommer, H., Klapp, D., Linton, E., Hurtado, H., & Roy, J. (2011) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2010.2051819 · Cited by 479
Optimal Protection Coordination for Microgrids With Grid-Connected and Islanded Capability
Najy, W., Zeineldin, H. H., & Woon, W. L. (2012) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2012.2192893 · Cited by 428
Self-citationThe Next Generation of Power Distribution Systems
Heydt, G. T. (2010) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2010.2080328 · Cited by 422
Protection Principles for Future Microgrids
Laaksonen, H. J. (2010) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2010.2066990 · Cited by 380
Nikkhajoei, H., & Lasseter, R. H. (2007) · IEEE Power Engineering Society General Meeting · doi:10.1109/pes.2007.385805 · Cited by 378
Ustun, T. S., Ozansoy, C., & Zayegh, A. (2012) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2012.2185072 · Cited by 335
A Protection Strategy and Microprocessor-Based Relay for Low-Voltage Microgrids
Zamani, M. A., Sidhu, T. S., & Yazdani, A. (2011) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2011.2120628 · Cited by 324
Blackburn, J. L., & Domin, T. J. (2006) · CRC Press eBooks · doi:10.1201/9781420017847 · Cited by 217
A voltage based protection for micro-grids containing power electronic converters
Al-Nasseri, H., Redfern, M. A., & Li, F. (2006) · IEEE Power Engineering Society General Meeting · doi:10.1109/pes.2006.1709423 · Cited by 195
Fault analysis and protection of a microgrid
Sortomme, E., Mapes, G. J., Foster, B. A., & Venkata, S. S. (2008) · North American Power Symposium (NAPS) · doi:10.1109/naps.2008.5307360 · Cited by 128
Adaptive over current protection for distribution feeders with distributed generators
Baran, M. E., & El-Markabi, I. M. S. (2005) · IEEE PES Power Systems Conference and Exposition · doi:10.1109/psce.2004.1397672 · Cited by 120
Cited by
Central Power Research Institute, Telukunta, V., Pradhan, J., Central Power Research Institute, Agrawal, A., Central Power Research Institute, Singh, M., Central Power Research Institute, Srivani, S. G., & R V College of Engineering (2017) · CSEE Journal of Power and Energy Systems · doi:10.17775/cseejpes.2017.00030 · Cited by 544
Intelligent Fault Detection Scheme for Microgrids With Wavelet-Based Deep Neural Networks
Yu, J. J. Q., Hou, Y., Lam, A. Y. S., & Li, V. O. K. (2019) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2017.2776310 · Cited by 451
Hooshyar, A., & Iravani, R. (2017) · Proceedings of the IEEE · doi:10.1109/jproc.2017.2669342 · Cited by 435
Data-Mining Model Based Intelligent Differential Microgrid Protection Scheme
Kar, S., Samantaray, S. R., & Zadeh, M. D. (2017) · IEEE Systems Journal · doi:10.1109/jsyst.2014.2380432 · Cited by 295
CNN-Based Transformer Model for Fault Detection in Power System Networks
Thomas, J. B., Chaudhari, S. G., K. V., S., & Verma, N. K. (2023) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2023.3238059 · Cited by 275
Metadata
- Authors
- Casagrande, E., Woon, W. L., Zeineldin, H. H., & Svetinovic, D.
- Venue
- IEEE Transactions on Smart Grid
- Published
- 2014-01
- Volume
- 5
- Issue
- 1
- Pages
- 29-37
- ISSN
- 1949-3053 (ISSN-L)
- 1949-3061
- OpenAlex
- W2063895100
- Cited by
- 276
- References
- 17
- FWCI
- 18.98
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.