The DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
MPC-Based Appliance Scheduling for Residential Building Energy Management Controller
Abstract
This paper proposes an appliance scheduling scheme for residential building energy management controllers, by taking advantage of the time-varying retail pricing enabled by the two-way communication infrastructure of the smart grid. Finite-horizon scheduling optimization problems are formulated to exploit operational flexibilities of thermal and non-thermal appliances using a model predictive control (MPC) method which incorporates both forecasts and newly updated information. For thermal appliance scheduling, the thermal mass of the building, which serves as thermal storage, is integrated into the optimization problem by modeling the thermodynamics of rooms in a building as constraints. Within the comfort range modeled by the predicted mean vote (PMV) index, thermal appliances are scheduled smartly together with thermal mass storage to hedge against high prices and make use of low-price time periods. For non-thermal appliance scheduling, in which delay and/or power consumption flexibilities are available, operation dependence of inter-appliance and intra-appliance is modeled to further exploit the price variation. Simulation results show that customers have notable energy cost savings on their electricity bills with time-varying pricing. The impact of customers' preferences of appliances usage on energy cost savings is also evaluated.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Mohsenian-Rad, A.-H., Wong, V. W. S., Jatskevich, J., Schober, R., & Leon-Garcia, A. (2010) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2010.2089069 · Cited by 2,744
Optimal Residential Load Control With Price Prediction in Real-Time Electricity Pricing Environments
Mohsenian-Rad, A.-H., & Leon-Garcia, A. (2010) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2010.2055903 · Cited by 1,838
ARIMA models to predict next-day electricity prices
Contreras, J., Espinola, R., Nogales, F. J., & Conejo, A. J. (2003) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2002.804943 · Cited by 1,553
Appliance Commitment for Household Load Scheduling
Du, P., & Lu, N. (2011) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2011.2140344 · Cited by 568
Day-ahead electricity price forecasting using wavelet transform combined with ARIMA and GARCH models
Tan, Z., Zhang, J., Wang, J., & Xu, J. (2010) · Applied Energy · doi:10.1016/j.apenergy.2010.05.012 · Cited by 332
Self-citationResidential Demand Response Using Reinforcement Learning
O'Neill, D., Levorato, M., Goldsmith, A., & Mitra, U. (2010) · 2010 First IEEE International Conference on Smart Grid Communications · doi:10.1109/smartgrid.2010.5622078 · Cited by 281
Oldewurtel, F., Ulbig, A., Parisio, A., Andersson, G., & Morari, M. (2010) · 49th IEEE Conference on Decision and Control (CDC) · doi:10.1109/cdc.2010.5717458 · Cited by 237
Study on Auto-DR and pre-cooling of commercial buildings with thermal mass in California
Yin, R., Xu, P., Piette, M. A., & Kiliccote, S. (2010) · Energy and Buildings · doi:10.1016/j.enbuild.2010.01.008 · Cited by 193
Liu, C., Wang, J., Botterud, A., Zhou, Y., & Vyas, A. (2012) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2012.2187687 · Cited by 165
Self-citationZong, Y., Kullmann, D., Thavlov, A., Gehrke, O., & Bindner, H. W. (2012) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2011.2177282 · Cited by 151
Cited by
Serale, G., Fiorentini, M., Capozzoli, A., Bernardini, D., & Bemporad, A. (2018) · Energies · doi:10.3390/en11030631 · Cited by 637
Ten Questions Concerning Model Predictive Control for Energy Efficient Buildings
Killian, M., & Kozek, M. (2016) · Building and Environment · doi:10.1016/j.buildenv.2016.05.034 · Cited by 463
Althaher, S., Mancarella, P., & Mutale, J. (2015) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2014.2388357 · Cited by 426
Li, H., Wang, Z., Hong, T., & Piette, M. A. (2021) · Advances in Applied Energy · doi:10.1016/j.adapen.2021.100054 · Cited by 411
From demand response to transactive energy: state of the art
CHEN, S., & LIU, C.-C. (2017) · Journal of Modern Power Systems and Clean Energy · doi:10.1007/s40565-016-0256-x · Cited by 279
A Distributed Direct Load Control Approach for Large-Scale Residential Demand Response
Chen, C., Wang, J., & Kishore, S. (2014) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2014.2307474 · Cited by 258
Self-citationForesee: A user-centric home energy management system for energy efficiency and demand response
Jin, X., Baker, K., Christensen, D., & Isley, S. (2017) · Applied Energy · doi:10.1016/j.apenergy.2017.08.166 · Cited by 204
Langner, F., Wang, W., Frahm, M., & Hagenmeyer, V. (2024) · Energy and Buildings · doi:10.1016/j.enbuild.2023.113753 · Cited by 73
Esmaeilzadeh, A., Deal, B., Yousefi-Koma, A., & Zakerzadeh, M. R. (2022) · Energies · doi:10.3390/en15228675 · Cited by 10
Metadata
- Authors
- Chen, C., Wang, J., Heo, Y., & Kishore, S.
- Venue
- IEEE Transactions on Smart Grid
- Published
- 2013-09
- Volume
- 4
- Issue
- 3
- Pages
- 1401-1410
- ISSN
- 1949-3053 (ISSN-L)
- 1949-3061
- OpenAlex
- W2078926545
- Cited by
- 287
- References
- 12
- FWCI
- 12.38
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.