The DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.
Hierarchical Control of Parallel AC-DC Converter Interfaces for Hybrid Microgrids
Open accessAbstract
In this paper, a hierarchical control system for parallel power electronics interfaces between ac bus and dc bus in a hybrid microgrid is presented. Both standalone and grid-connected operation modes in the dc side of the microgrid are analyzed. Concretely, a three-level hierarchical control system is implemented. In the primary control level, the decentralized control is realized by using the droop method. Local ac current proportional-resonant controller and dc voltage proportional-integral controller are employed. When the local load is connected to the dc bus, dc droop control is applied to obtain equal or proportional dc load current sharing. The common secondary control level is designed to eliminate the dc bus voltage deviation produced by the droop control, with dc bus voltage in the hybrid microgrid boosted to an acceptable range. After guaranteeing the performance of the dc side standalone operation by means of the primary and secondary control levels, the tertiary control level is thereafter employed to perform the connection to an external dc system. Meanwhile, the impact of the bandwidth of the secondary and tertiary control levels is discussed. The closed-loop model including all the three control levels is developed in order to adjust the main control parameters and study the system stability. Experimental results of a 2 × 2.2 kW parallel ac-dc converter system have shown satisfactory realization of the designed system.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Guerrero, J. M., Vasquez, J. C., Matas, J., de Vicuna, L. G., & Castilla, M. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2066534 · Cited by 5,075
Self-citationPower-Electronic Systems for the Grid Integration of Renewable Energy Sources: A Survey
Carrasco, J. M., Franquelo, L. G., Bialasiewicz, J. T., Galvan, E., PortilloGuisado, R. C., Prats, M. A. M., Leon, J. I., & Moreno-Alfonso, N. (2006) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2006.878356 · Cited by 4,018
Burton, T., Sharpe, D., Jenkins, N., & Bossanyi, E. (2001) · Wiley eBooks · doi:10.1002/0470846062 · Cited by 3,559
Power electronics as efficient interface in dispersed power generation systems
Blaabjerg, F., Chen, Z., & Kjaer, S. B. (2004) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2004.833453 · Cited by 2,588
A Hybrid AC/DC Microgrid and Its Coordination Control
Liu, X., Wang, P., & Loh, P. C. (2011) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2011.2116162 · Cited by 1,192
Lu, X., Guerrero, J. M., Sun, K., & Vasquez, J. C. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2266419 · Cited by 1,049
Self-citationAnand, S., Fernandes, B. G., & Guerrero, J. (2013) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2012.2215055 · Cited by 920
Self-citationControl Strategy for Flexible Microgrid Based on Parallel Line-Interactive UPS Systems
Guerrero, J. M., Vasquez, J. C., Matas, J., Castilla, M., & de Vicuna, L. G. (2009) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2008.2009274 · Cited by 788
Self-citationAutonomous Operation of Hybrid Microgrid With AC and DC Subgrids
Loh, P. C., Li, D., Chai, Y. K., & Blaabjerg, F. (2013) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2012.2214792 · Cited by 727
Control of Distributed Uninterruptible Power Supply Systems
Guerrero, J. M., Hang, L., & Uceda, J. (2008) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2008.924173 · Cited by 700
Self-citation
Cited by
DC Microgrids–Part I: A Review of Control Strategies and Stabilization Techniques
Dragicevic, T., Lu, X., Vasquez, J., & Guerrero, J. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2015.2478859 · Cited by 1,564
Self-citationDC Microgrids—Part II: A Review of Power Architectures, Applications, and Standardization Issues
Dragicevic, T., Lu, X., Vasquez, J. C., & Guerrero, J. M. (2016) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2015.2464277 · Cited by 1,451
Self-citationLu, X., Sun, K., Guerrero, J. M., Vasquez, J. C., & Huang, L. (2014) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2013.2279374 · Cited by 752
Self-citationNetworked Microgrids for Enhancing the Power System Resilience
Li, Z., Shahidehpour, M., Aminifar, F., Alabdulwahab, A., & Al-Turki, Y. (2017) · Proceedings of the IEEE · doi:10.1109/jproc.2017.2685558 · Cited by 640
DC Microgrid Planning, Operation, and Control: A Comprehensive Review
Al-Ismail, F. S. (2021) · IEEE Access · doi:10.1109/access.2021.3062840 · Cited by 542
Metadata
- Authors
- Lu, X., Guerrero, J. M., Sun, K., Vasquez, J. C., Teodorescu, R., & Huang, L.
- Venue
- IEEE Transactions on Smart Grid
- Published
- 2014-03
- Volume
- 5
- Issue
- 2
- Pages
- 683-692
- ISSN
- 1949-3053 (ISSN-L)
- 1949-3061
- OpenAlex
- W2054493301
- Cited by
- 401
- References
- 21
- FWCI
- 40.77
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Hierarchical Control of Parallel AC-DC Converter Interfaces for Hybrid Microgrids. https://app.cochat.ai/papers/10.1109/tsg.2013.2272327
- The paper
- Lu, X., Guerrero, J. M., Sun, K., Vasquez, J. C., Teodorescu, R., & Huang, L. (2014). Hierarchical Control of Parallel AC-DC Converter Interfaces for Hybrid Microgrids. IEEE Transactions on Smart Grid. https://doi.org/10.1109/tsg.2013.2272327
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.