Inverter-Less Hybrid Voltage/Var Control for Distribution Circuits With Photovoltaic Generators
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
This paper proposes a hybrid voltage/var control (VVC) architecture for distribution systems with a high PV penetration. The architecture consists of two control loops: coordinated normal control loop and uncoordinated transient cloud movement control loop. In the first loop, hourly dispatches are scheduled for on-load tap changer (OLTC), capacitor banks (CBs), and static var compensators (SVCs) based on forecasted load and PV power output so as to minimize power losses and voltage deviations. The second loop is triggered when large variations of PV power output caused by rapid cloud movement happen. All SVCs and CBs become self-controlled based on local voltage measurements with the single control objective to minimize voltage deviations. SVCs will operate firstly to flatten the voltage profile. If SVCs fail, CBs will switch to provide reactive power support. A time-adaptive delay is applied to each CB to avoid overcompensation. Case studies show the proposed method can optimize the system operation and is effective in voltage regulation with PV generators.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Inverter VAR control for distribution systems with renewables
Farivar, M., Clarke, C. R., Low, S. H., & Chandy, K. M. (2011) · 2011 IEEE International Conference on Smart Grid Communications (SmartGridComm) · doi:10.1109/smartgridcomm.2011.6102366 · Cited by 331 · cited 2×
“The algorithms proposed in [16] and [17] require complex communications.”
Background
Cited by
Coordinated Energy Management of Networked Microgrids in Distribution Systems
Wang, Z., Chen, B., Wang, J., Begovic, M. M., & Chen, C. (2015) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2014.2329846 · Cited by 584
Self-citationDistribution Locational Marginal Pricing (DLMP) for Congestion Management and Voltage Support
Bai, L., Wang, J., Wang, C., Chen, C., & Li, F. (2018) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2017.2767632 · Cited by 446
Self-citationRobust Optimization Based Optimal DG Placement in Microgrids
Wang, Z., Chen, B., Wang, J., Kim, J., & Begovic, M. M. (2014) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2014.2321748 · Cited by 358
Self-citationMulti-Timescale Coordinated Voltage/Var Control of High Renewable-Penetrated Distribution Systems
Xu, Y., Dong, Z. Y., Zhang, R., & Hill, D. J. (2017) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2017.2669343 · Cited by 340
Wang, S., Chen, S., Ge, L., & Wu, L. (2016) · IEEE Transactions on Sustainable Energy · doi:10.1109/tste.2016.2529627 · Cited by 302
Sun, X., & Qiu, J. (2021) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2021.3052998 · Cited by 289
Wang, L., Bai, F., Yan, R., & Saha, T. K. (2018) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2018.2789897 · Cited by 229
Wang, Z., Wang, J., Chen, B., Begovic, M. M., & He, Y. (2014) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2014.2329842 · Cited by 183
“Reference [13] proposed a hybrid voltage/var control for a distribution system with PV generation.”
BackgroundSelf-citationNational Renewable Energy Lab. (NREL), G., Palmintier, B., USDOE Office of Energy Efficiency and Renewable Energy (EERE), S. E. T. O. (.-4., Broderick, R., Mather, B., Coddington, M., Baker, K., Ding, F., Reno, M., Lave, M., et al. (2016) · doi:10.2172/1253980 · Cited by 108
Xu, R., Zhang, C., Xu, Y., Dong, Z., & Zhang, R. (2022) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2021.3126761 · Cited by 83
Data-driven combined central and distributed volt/var control in active distribution networks
Sun, X., Qiu, J., Tao, Y., & Zhao, J. (2023) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2022.3213587 · Cited by 42
“This process is achieved by some equivalent substitutions with binary variables and details are found in [31].”
BackgroundMethodA dual time scale Voltage/Var control method for active distribution networks based on data-driven
Li, H., Su, P., Wang, C., Yue, Z., Wang, Z., & Wang, C. (2025) · Electrical Engineering · doi:10.1007/s00202-024-02576-5 · Cited by 5
“…(MINLP), and it is difficult to solve it, in order to simplify this optimization problem, the optimization problem is transformed into a MISOCP model by using the principle of the second-order conic relaxation and the linearization method that facilitates the use of the solver for solving [25].”
Self-citation
Metadata
- Authors
- Wang, Z., Chen, H., Wang, J., & Begovic, M.
- Venue
- IEEE Transactions on Smart Grid
- Published
- 2014-11
- Volume
- 5
- Issue
- 6
- Pages
- 2718-2728
- ISSN
- 1949-3053 (ISSN-L)
- 1949-3061
- OpenAlex
- W2013287596
- Cited by
- 120
- References
- 1
- FWCI
- 4.95
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.