The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Distributed Secondary Level Control for Energy Storage Management in DC Microgrids
Abstract
DC microgrids have been known to be a promising solution for improving renewable energy integration with electrical grid and enhancing the system's overall energy efficiency. A key component of this microgrid is the energy storage system, which besides smoothing the intermittent behavior of renewable sources, also allows intentional islanding and the execution of optimization routines to improve the microgrid performance. Assuming that storage systems in commercial and residential buildings will mostly be composed of multiple storage units, an energy storage management system, which provides charge/discharge monitoring and state-of-charge (SOC) equalization, is needed to prevent overcharging the units or their uneven use, which can lead to faster deterioration of battery banks. This paper proposes an energy storage management system based on distributed secondary level control, which promotes charge/discharge control and provides SOC equalization simultaneously. The SOC imbalance compensation alters the energy storage unit virtual droop resistance according to the difference between the unit SOC and the microgrid average SOC, thus the compensation intensity is dependent on the imbalance level being suitable to be employed in dc bus signaling controlled microgrids.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Guerrero, J. M., Vasquez, J. C., Matas, J., de Vicuna, L. G., & Castilla, M. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2066534 · Cited by 5,075
Olivares, D. E., Mehrizi-Sani, A., Etemadi, A. H., Canizares, C. A., Iravani, R., Kazerani, M., Hajimiragha, A. H., Gomis-Bellmunt, O., Saeedifard, M., Palma-Behnke, R., et al. (2014) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2013.2295514 · Cited by 3,137 · cited 2×
“The performance of a DBS controlled microgrid can also be optimized through the employment of hierarchical layers of control [13], [18], a communication network will be involved, a failure on it will interfere with the system performance but not necessarily preclude its operation.”
Background
Cited by
DC Microgrid Planning, Operation, and Control: A Comprehensive Review
Al-Ismail, F. S. (2021) · IEEE Access · doi:10.1109/access.2021.3062840 · Cited by 542
Review on Control of DC Microgrids
Meng, L., Shafiee, Q., Ferrari Trecate, G., Karimi, H., Fulwani, D., Lu, X., & Guerrero, J. M. (2017) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2017.2690219 · Cited by 513
Distributed Control Strategies for Microgrids: An Overview
Espina, E., Llanos, J., Burgos-Mellado, C., Cardenas-Dobson, R., Martinez-Gomez, M., & Saez, D. (2020) · IEEE Access · doi:10.1109/access.2020.3032378 · Cited by 415
Zeraati, M., Hamedani Golshan, M. E., & Guerrero, J. M. (2018) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2016.2636217 · Cited by 395
Primary and secondary control in DC microgrids: a review
GAO, F., KANG, R., CAO, J., & YANG, T. (2019) · Journal of Modern Power Systems and Clean Energy · doi:10.1007/s40565-018-0466-5 · Cited by 314
Metadata
- Authors
- Oliveira, T. R., Goncalves Silva, W. W. A., & Donoso-Garcia, P. F.
- Venue
- IEEE Transactions on Smart Grid
- Published
- 2017-11
- Volume
- 8
- Issue
- 6
- Pages
- 2597-2607
- ISSN
- 1949-3053 (ISSN-L)
- 1949-3061
- OpenAlex
- W2335098274
- Cited by
- 187
- References
- 2
- FWCI
- 12.91
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.