Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 297

The DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.

Online Detection of Stealthy False Data Injection Attacks in Power System State Estimation

Ashok, Aditya, Govindarasu, Manimaran, Ajjarapu, Venkataramana·2016·IEEE Transactions on Smart Grid

Abstract

State estimation is one of the fundamental functions in modern power grid operations that provide operators with situational awareness and is used by several applications like contingency analysis and power markets. Several research in the recent past have highlighted the vulnerability of state estimators to stealthy false data injection attacks that bypass bad data detection mechanisms. They primarily focused on identifying stealthy attack vectors and characterizing their impacts on state estimates. Existing mitigation measures either focus on masking the effect of attacks through redundant measurements or prevent attacks by increasing the cyber security of associated sensors and communication channels. The solutions based on these offline approaches make specific assumptions about the nature of attacks and of the system, which are often restrictive and grossly inadequate to deal with dynamically evolving cyber threats and changing system configurations. In this paper, we propose an online anomaly detection algorithm that utilizes load forecasts, generation schedules, and synchrophasor data to detect measurement anomalies. We provide some insight into the factors that affect the performance of the proposed algorithm. We also describe an empirical method to obtain the minimum attack magnitudes and the detection thresholds for meeting specified false positive and true positive rates. Finally, we evaluated the performance of the proposed algorithm using the IEEE 14 bus power system model for several measures (false positive, false negative, and thresholds). We observed that the best performance of the proposed algorithm relies on finding the right balance between the minimum attack magnitude and detection thresholds. We also observed that the minimum attack magnitudes and detection thresholds could be further improved through the use of a combination of more accurate forecasts and PMU measurements.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tsg.2016.2596298

Cites

17 of 17 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 17 references

Cited by

See all 297

Metadata

Authors
Ashok, A., Govindarasu, M., & Ajjarapu, V.
Venue
IEEE Transactions on Smart Grid
Published
2016
Pages
1-1
ISSN
  • 1949-3053 (ISSN-L)
  • 1949-3061
OpenAlex
W2477566801
Cited by
297
References
17
FWCI
19.92
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Online Detection of Stealthy False Data Injection Attacks in Power System State Estimation. https://app.cochat.ai/papers/10.1109/tsg.2016.2596298
The paper
Ashok, A., Govindarasu, M., & Ajjarapu, V. (2016). Online Detection of Stealthy False Data Injection Attacks in Power System State Estimation. IEEE Transactions on Smart Grid. https://doi.org/10.1109/tsg.2016.2596298

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.