Reverse Power Flow Control in a ST-Fed Distribution Grid
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
The massive integration of distributed generation in the grid poses new challenges to the system operators, like the reverse power flow from the low voltage (LV) to medium voltage (MV) grid. In the case of high DG power production and low load absorption, the voltage rises in the line reaching the upper voltage limit. At this regard the smart transformer (ST) offers a new possibility to limit the reverse power flow in the MV grids. The ST can adapt the voltage waveform modifying the frequency in order to interact with the local distributed generation, that are normally equipped with droop characteristic. However, when a fast change in the frequency is applied to avoid reverse power flow to MV grid, stability problems, so far not investigated, arise. In this paper, the stability analysis has been performed analytically and validated by means of control-hardware-in-loop in a real time digital simulator and with experimental results in laboratory.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Review of Solid-State Transformer Technologies and Their Application in Power Distribution Systems
She, X., Huang, A. Q., & Burgos, R. (2013) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2013.2277917 · Cited by 1,164
The Smart Transformer: Impact on the Electric Grid and Technology Challenges
Liserre, M., Buticchi, G., Andresen, M., De Carne, G., Costa, L. F., & Zou, Z.-X. (2016) · IEEE Industrial Electronics Magazine · doi:10.1109/mie.2016.2551418 · Cited by 445 · cited 1×
“The Smart Transformer (ST) is a three-stage power electronics transformer [23], [24] that transforms the voltage from the MV to the LV grid, makes available the DC grid connections [25], provides new services to the distribution grids like the load identification and control [26], [27] and offers new solutions to curr…”
BackgroundSelf-citation
Cited by
Ferreira Costa, L., De Carne, G., Buticchi, G., & Liserre, M. (2017) · IEEE Power Electronics Magazine · doi:10.1109/mpel.2017.2692381 · Cited by 303
Self-citationEjuh Che, E., Roland Abeng, K., Iweh, C. D., Tsekouras, G. J., & Fopah-Lele, A. (2025) · Energies · doi:10.3390/en18030689 · Cited by 160
Augmenting Zero Trust Network Architecture to enhance security in virtual power plants
Alagappan, A., Venkatachary, S. K., & Andrews, L. J. B. (2022) · Energy Reports · doi:10.1016/j.egyr.2021.11.272 · Cited by 81
Sizing and SOC Management of a Smart-Transformer-Based Energy Storage System
Kumar, C., Zhu, R., Buticchi, G., & Liserre, M. (2018) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2017.2784389 · Cited by 71
“The advantages of the ST in the electric grid have also been demonstrated through different operational features and ancillary services, for example, damping of LV grid resonance [11], better control and sharing of the power [12], var/volt control [13], a frequencyadaptive ST in the LV grid [14], dc microgrid operatio…”
BackgroundSelf-citationSadeghian, H., & Wang, Z. (2020) · Renewable Energy · doi:10.1016/j.renene.2019.09.117 · Cited by 64
Metadata
- Authors
- De Carne, G., Buticchi, G., Zou, Z., & Liserre, M.
- Venue
- IEEE Transactions on Smart Grid
- Published
- 2018-07
- Volume
- 9
- Issue
- 4
- Pages
- 3811-3819
- ISSN
- 1949-3053 (ISSN-L)
- 1949-3061
- OpenAlex
- W2570301988
- Cited by
- 109
- References
- 2
- FWCI
- 8.95
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Reverse Power Flow Control in a ST-Fed Distribution Grid. https://app.cochat.ai/papers/10.1109/tsg.2017.2651147
- The paper
- De Carne, G., Buticchi, G., Zou, Z., & Liserre, M. (2018). Reverse Power Flow Control in a ST-Fed Distribution Grid. IEEE Transactions on Smart Grid. https://doi.org/10.1109/tsg.2017.2651147
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.