Optimal Coordination of Building Loads and Energy Storage for Power Grid and End User Services
Open accessThe DOI matches its Crossref record; 30 of the 30 references it cites were found in a registry or an index.
Abstract
Demand response and energy storage play a profound role in the smart grid. The focus of this paper is to evaluate benefits of coordinating flexible loads and energy storage to provide power grid and end user services. We present a generalized battery model (GBM) to describe the flexibility of building loads and energy storage. An optimization-based approach is proposed to characterize the parameters (power and energy limits) of the GBM for flexible building loads. We then develop optimal coordination algorithms to provide power grid and end user services such as energy arbitrage, frequency regulation, spinning reserve, as well as energy cost and demand charge reduction. Several case studies have been performed to demonstrate the efficacy of the GBM and coordination algorithms, and evaluate the benefits of using their flexibility for power grid and end user services. We show that optimal coordination yields significant cost savings and revenue. Moreover, the best option for power grid services is to provide energy arbitrage and frequency regulation. Furthermore, when coordinating flexible loads with energy storage to provide end user services, it is recommended to consider demand charge in addition to time-of-use price in order to flatten the aggregate power profile.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Callaway, D. S. (2009) · Energy Conversion and Management · doi:10.1016/j.enconman.2008.12.012 · Cited by 759 · cited 1×
“The temperature dynamics of each AC (indexed by i) can be described by the following hybrid model [17], [25], [26],”
MethodAggregate flexibility of thermostatically controlled loads
Hao, H., Sanandaji, B. M., Poolla, K., & Vincent, T. L. (2015) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2014.2328865 · Cited by 733 · cited 9×
“The temperature dynamics of each AC (indexed by i) can be described by the following hybrid model [17], [25], [26],”
BackgroundMethodSelf-citationState Estimation and Control of Electric Loads to Manage Real-Time Energy Imbalance
Mathieu, J. L., Koch, S., & Callaway, D. S. (2013) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2012.2204074 · Cited by 574
Computing in Operations Research Using Julia
Lubin, M., & Dunning, I. (2015) · INFORMS journal on computing · doi:10.1287/ijoc.2014.0623 · Cited by 367 · cited 1×
“The parameters of the commercial and residential HVAC systems are adopted from [17], [21], and their flexibility are characterized using algorithms (10)-(12) formulated in Julia and JuMP [36].”
Method(2012) · IEEE Control Systems · doi:10.1109/mcs.2011.2172532 · Cited by 347 · cited 1×
“On the other hand, some customized aggregate load models such as the partial differential equation model [34] and the large-scale nonlinear system model [35] do not offer such convenience.”
BackgroundMalhame, R., & Chong, C.-Y. (1985) · IEEE Transactions on Automatic Control · doi:10.1109/tac.1985.1104071 · Cited by 307 · cited 1×
“On the other hand, some customized aggregate load models such as the partial differential equation model [34] and the large-scale nonlinear system model [35] do not offer such convenience.”
BackgroundYin, R., Kara, E. C., Li, Y., DeForest, N., Wang, K., Yong, T., & Stadler, M. (2016) · Applied Energy · doi:10.1016/j.apenergy.2016.05.090 · Cited by 307
Transactive Control of Commercial Buildings for Demand Response
Hao, H., Corbin, C. D., Kalsi, K., & Pratt, R. G. (2017) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2016.2559485 · Cited by 285 · cited 2×
“, n, its thermal dynamics are given by the following first order model [20], [21],”
MethodSelf-citationAncillary Service to the Grid Through Control of Fans in Commercial Building HVAC Systems
Hao, H., Lin, Y., Kowli, A. S., Barooah, P., & Meyn, S. (2014) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2014.2322604 · Cited by 273
Self-citationExperimental Evaluation of Frequency Regulation From Commercial Building HVAC Systems
Lin, Y., Barooah, P., Meyn, S., & Middelkoop, T. (2015) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2014.2381596 · Cited by 248
Cited by
Grid-connected battery energy storage system: a review on application and integration
Zhao, C., Andersen, P. B., Træholt, C., & Hashemi, S. (2023) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2023.113400 · Cited by 305
Metadata
- Authors
- Hao, H., Wu, D., Lian, J., & Yang, T.
- Venue
- IEEE Transactions on Smart Grid
- Published
- 2018-09
- Volume
- 9
- Issue
- 5
- Pages
- 4335-4345
- ISSN
- 1949-3053 (ISSN-L)
- 1949-3061
- OpenAlex
- W2571862639
- Cited by
- 203
- References
- 30
- FWCI
- 7.94
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Optimal Coordination of Building Loads and Energy Storage for Power Grid and End User Services. https://app.cochat.ai/papers/10.1109/tsg.2017.2655083
- The paper
- Hao, H., Wu, D., Lian, J., & Yang, T. (2018). Optimal Coordination of Building Loads and Energy Storage for Power Grid and End User Services. IEEE Transactions on Smart Grid. https://doi.org/10.1109/tsg.2017.2655083
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.