The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Comprehensive Optimization Model for Sizing and Siting of DG Units, EV Charging Stations, and Energy Storage Systems
Open accessAbstract
The sizing and siting of renewable resources-based distributed generation (DG) units has been a topic of growing interest, especially during the last decade due to the increasing interest in renewable energy systems and the possible impacts of their volatility on distribution system operation. This paper goes beyond the existing literature by presenting a comprehensive optimization model for the sizing and siting of different renewable resources-based DG units, electric vehicle charging stations, and energy storage systems within the distribution system. The proposed optimization model is formulated as a second order conic programming problem, considering also the time-varying nature of DG generation and load consumption, in contrast with the majority of the relevant studies that have been based on static values.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Erdinc, O., Paterakis, N. G., Mendes, T. D. P., Bakirtzis, A. G., & P. S. Catalao, J. (2015) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2014.2352650 · Cited by 462
Self-citationJayasekara, N., Masoum, M. A. S., & Wolfs, P. J. (2016) · IEEE Transactions on Sustainable Energy · doi:10.1109/tste.2015.2487360 · Cited by 260 · cited 1×
“Moreover, the introduction of distributed energy storage systems (ESSs) within the distribution system has been also recognized by SOs as a means of enhancing the operational flexibility [9], [10].”
BackgroundOptimal allocation, sizing of PHEV parking lots in distribution system
El-Zonkoly, A., & dos Santos Coelho, L. (2015) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2014.12.026 · Cited by 92 · cited 1×
“Two different studies considering the sizing and siting of EV charging stations and ESS units within the distribution system without taking DG units into account can be found in [20] and [21].”
Background
Cited by
Mastoi, M. S., Zhuang, S., Munir, H. M., Haris, M., Hassan, M., Usman, M., Bukhari, S. S. H., & Ro, J.-S. (2022) · Energy Reports · doi:10.1016/j.egyr.2022.09.011 · Cited by 523
Yuvaraj, T., Devabalaji, K. R., Kumar, J. A., Thanikanti, S. B., & Nwulu, N. I. (2024) · IEEE Access · doi:10.1109/access.2023.3349274 · Cited by 249
Optimal location of PEVCSs using MAS and ER approach
Jiang, C., Jing, Z., Ji, T., & Wu, Q. (2018) · IET Generation, Transmission & Distribution · doi:10.1049/iet-gtd.2017.1907 · Cited by 24
Metadata
- Authors
- Erdinc, O., Tascikaraoglu, A., Paterakis, N. G., Dursun, I., Sinim, M. C., & Catalao, J. P. S.
- Venue
- IEEE Transactions on Smart Grid
- Published
- 2018-07
- Volume
- 9
- Issue
- 4
- Pages
- 3871-3882
- ISSN
- 1949-3053 (ISSN-L)
- 1949-3061
- OpenAlex
- W2768952788
- Cited by
- 167
- References
- 3
- FWCI
- 5.03
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Comprehensive Optimization Model for Sizing and Siting of DG Units, EV Charging Stations, and Energy Storage Systems. https://app.cochat.ai/papers/10.1109/tsg.2017.2777738
- The paper
- Erdinc, O., Tascikaraoglu, A., Paterakis, N. G., Dursun, I., Sinim, M. C., & Catalao, J. P. S. (2018). Comprehensive Optimization Model for Sizing and Siting of DG Units, EV Charging Stations, and Energy Storage Systems. IEEE Transactions on Smart Grid. https://doi.org/10.1109/tsg.2017.2777738
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.