The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Self-Calibrating View-Invariant Gait Biometrics
Abstract
We present a new method for viewpoint independent gait biometrics. The system relies on a single camera, does not require camera calibration, and works with a wide range of camera views. This is achieved by a formulation where the gait is self-calibrating. These properties make the proposed method particularly suitable for identification by gait, where the advantages of completely unobtrusiveness, remoteness, and covertness of the biometric system preclude the availability of camera information and specific walking directions. The approach has been assessed for feature extraction and recognition capabilities on the SOTON gait database and then evaluated on a multiview database to establish recognition capability with respect to view invariance. Moreover, tests on the multiview CASIA-B database, composed of more than 2270 video sequences with 65 different subjects walking freely along different walking directions, have been performed. The obtained results show that human identification by gait can be achieved without any knowledge of internal or external camera parameters with a mean correct classification rate of 73.6% across all views using purely dynamic gait features. The performance of the proposed method is particularly encouraging for application in surveillance scenarios.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Yu, S., Tan, D., & Tan, T. (2006) · 18th International Conference on Pattern Recognition (ICPR'06) · doi:10.1109/icpr.2006.67 · Cited by 1,056
Cited by
A Comprehensive Study on Cross-View Gait Based Human Identification with Deep CNNs
Wu, Z., Huang, Y., Wang, L., Wang, X., & Tan, T. (2017) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.2016.2545669 · Cited by 729
GEINet: View-invariant gait recognition using a convolutional neural network
Shiraga, K., Makihara, Y., Muramatsu, D., Echigo, T., & Yagi, Y. (2016) · 2016 International Conference on Biometrics (ICB) · doi:10.1109/icb.2016.7550060 · Cited by 468
Takemura, N., Makihara, Y., Muramatsu, D., Echigo, T., & Yagi, Y. (2018) · IPSJ Transactions on Computer Vision and Applications · doi:10.1186/s41074-018-0039-6 · Cited by 451
Gait Recognition via Effective Global-Local Feature Representation and Local Temporal Aggregation
Lin, B., Zhang, S., & Yu, X. (2021) · 2021 IEEE/CVF International Conference on Computer Vision (ICCV) · doi:10.1109/iccv48922.2021.01438 · Cited by 334
Robust view transformation model for gait recognition
Zheng, S., Zhang, J., Huang, K., He, R., & Tan, T. (2011) · 2011 18th IEEE International Conference on Image Processing · doi:10.1109/icip.2011.6115889 · Cited by 301
Metadata
- Authors
- Goffredo, M., Bouchrika, I., Carter, J. N., & Nixon, M. S.
- Venue
- IEEE Transactions on Systems, Man, and Cybernetics, Part B (Cybernetics)
- Published
- 2010-08
- Volume
- 40
- Issue
- 4
- Pages
- 997-1008
- ISSN
- 1083-4419 (ISSN-L)
- OpenAlex
- W2148568366
- Cited by
- 204
- References
- 1
- FWCI
- 5.05
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Self-Calibrating View-Invariant Gait Biometrics. https://app.cochat.ai/papers/10.1109/tsmcb.2009.2031091
- The paper
- Goffredo, M., Bouchrika, I., Carter, J. N., & Nixon, M. S. (2010). Self-Calibrating View-Invariant Gait Biometrics. IEEE Transactions on Systems, Man, and Cybernetics, Part B (Cybernetics). https://doi.org/10.1109/tsmcb.2009.2031091
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.