A Switching Regime Model for the EMG-Based Control of a Robot Arm
Open accessThe DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
Human-robot control interfaces have received increased attention during the last decades. These interfaces increasingly use signals coming directly from humans since there is a strong necessity for simple and natural control interfaces. In this paper, electromyographic (EMG) signals from the muscles of the human upper limb are used as the control interface between the user and a robot arm. A switching regime model is used to decode the EMG activity of 11 muscles to a continuous representation of arm motion in the 3-D space. The switching regime model is used to overcome the main difficulties of the EMG-based control systems, i.e., the nonlinearity of the relationship between the EMG recordings and the arm motion, as well as the nonstationarity of EMG signals with respect to time. The proposed interface allows the user to control in real time an anthropomorphic robot arm in the 3-D space. The efficiency of the method is assessed through real-time experiments of four persons performing random arm motions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
McLachlan, G., & Peel, D. (2000) · Wiley Series in Probability and Statistics · doi:10.1002/0471721182 · Cited by 10,991
Learning to control a brain–machine interface for reaching and grasping by primates
Carmena, J. M., Lebedev, M. A., Crist, R. E., O'Doherty, J. E., Santucci, D. M., Dimitrov, D. F., Patil, P. G., Henriquez, C. S., & Nicolelis, M. A. L. (2003) · PLoS Biology · doi:10.1371/journal.pbio.0000042 · Cited by 1,761 · cited 1×
“The linear filter method, widely used in the literature for decoding motion using neural signals [44], was used.”
MethodControl of Multifunctional Prosthetic Hands by Processing the Electromyographic Signal
Zecca, M., Micera, S., Carrozza, M. C., & Dario, P. (2002) · Critical Reviews? in Biomedical Engineering · doi:10.1615/critrevbiomedeng.v30.i456.80 · Cited by 606
An exoskeletal robot for human elbow motion support‐sensor fusion, adaptation, and control
Kiguchi, K., Kariya, S., Watanabe, K., Izumi, K., & Fukuda, T. (2001) · IEEE Transactions on Systems, Man and Cybernetics, Part B (Cybernetics) · doi:10.1109/3477.931520 · Cited by 159 · cited 1×
“Arm exoskeletons [11] and arm power amplifiers [12] have used EMG signals as control interface in the past.”
Cited by
Intention-Based EMG Control for Powered Exoskeletons
Lenzi, T., De Rossi, S. M. M., Vitiello, N., & Carrozza, M. C. (2012) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2012.2198821 · Cited by 400
Building the Ninapro database: A resource for the biorobotics community
Atzori, M., Gijsberts, A., Heynen, S., Hager, A.-G. M., Deriaz, O., van der Smagt, P., Castellini, C., Caputo, B., & Muller, H. (2012) · 2012 4th IEEE RAS & EMBS International Conference on Biomedical Robotics and Biomechatronics (BioRob) · doi:10.1109/biorob.2012.6290287 · Cited by 262
A survey of sensor fusion methods in wearable robotics
Novak, D., & Riener, R. (2015) · Robotics and Autonomous Systems · doi:10.1016/j.robot.2014.08.012 · Cited by 252
Ison, M., & Artemiadis, P. (2014) · Journal of Neural Engineering · doi:10.1088/1741-2560/11/5/051001 · Cited by 225
Self-citationsEMG-based continuous estimation of joint angles of human legs by using BP neural network
Zhang, F., Li, P., Hou, Z.-G., Lu, Z., Chen, Y., Li, Q., & Tan, M. (2012) · Neurocomputing · doi:10.1016/j.neucom.2011.05.033 · Cited by 202
“For example, in [23], Artemiadis provided a switching regime model for decoding the sEMG activity of 11 muscles to a continuous representation of arm motion in the 3-D space, and this method proposed an interface for controlling anthropomorphic robot in real time.”
Metadata
- Authors
- Artemiadis, P. K., & Kyriakopoulos, K. J.
- Venue
- IEEE Transactions on Systems, Man, and Cybernetics, Part B (Cybernetics)
- Published
- 2011-02
- Volume
- 41
- Issue
- 1
- Pages
- 53-63
- ISSN
- 1083-4419 (ISSN-L)
- 1941-0492
- OpenAlex
- W2157409090
- Cited by
- 143
- References
- 4
- FWCI
- 4.91
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A Switching Regime Model for the EMG-Based Control of a Robot Arm. https://app.cochat.ai/papers/10.1109/tsmcb.2010.2045120
- The paper
- Artemiadis, P. K., & Kyriakopoulos, K. J. (2011). A Switching Regime Model for the EMG-Based Control of a Robot Arm. IEEE Transactions on Systems, Man, and Cybernetics, Part B (Cybernetics). https://doi.org/10.1109/tsmcb.2010.2045120
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.