The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Adaptive Control of Grid-Connected Inverters Based on Online Grid Impedance Measurements
Abstract
Stability of a grid-connected inverter depends on the ratio of the grid impedance to the inverter impedance. Since the grid impedance changes during normal power system conditions, this paper proposes a gain-scheduling adaptive control system that uses online grid impedance measurements. For grid impedance measurement, an impulse-response analysis method is programmed in the digital-signal processor (DSP) of the grid-connected inverter. For adaptation, a Routh–Hurwitz stability analysis approach is used to derive, analytically, the stable operation boundaries of the interconnected system. To simplify the analytical derivations, the grid impedance is assumed inductive at low frequencies and curve fitted to the online impedance measurements. Experimental measurements demonstrate the improvement in system stability, when the impedance identification and adaptive control algorithms are programmed together in the DSP of a three-phase inverter, which is connected to a grid with a variable feeder impedance.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Impedance-Based Stability Criterion for Grid-Connected Inverters
Sun, J. (2011) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2011.2136439 · Cited by 2,574
Self-citationImpedance Modeling and Analysis of Grid-Connected Voltage-Source Converters
Cespedes, M., & Sun, J. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2262473 · Cited by 1,167
Self-citationInput-Admittance Calculation and Shaping for Controlled Voltage-Source Converters
Harnefors, L., Bongiorno, M., & Lundberg, S. (2007) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2007.904022 · Cited by 1,117
Impedance-Based Stability and Transient-Performance Assessment Applying Maximum Peak Criteria
Vesti, S., Suntio, T., Oliver, J. A., Prieto, R., & Cobos, J. A. (2013) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2012.2220157 · Cited by 180
Non-parametric methods of system identification
Wellstead, P. E. (1981) · Automatica · doi:10.1016/0005-1098(81)90084-4 · Cited by 147
New Techniques for Measuring Impedance Characteristics of Three-Phase AC Power Systems
Familiant, Y. A., Huang, J., Corzine, K. A., & Belkhayat, M. (2009) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2009.2016966 · Cited by 118
Cited by
Zhang, X., Xia, D., Fu, Z., Wang, G., & Xu, D. (2018) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2018.2811718 · Cited by 262
Charging Infrastructure and Grid Integration for Electromobility
Rivera, S., Goetz, S. M., Kouro, S., Lehn, P. W., Pathmanathan, M., Bauer, P., & Mastromauro, R. A. (2023) · Proceedings of the IEEE · doi:10.1109/jproc.2022.3216362 · Cited by 233
Analysis and Stabilization of a Smart Transformer-Fed Grid
Zou, Z.-X., Buticchi, G., & Liserre, M. (2018) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2017.2733450 · Cited by 41
Metadata
- Authors
- Cespedes, M., & Sun, J.
- Venue
- IEEE Transactions on Sustainable Energy
- Published
- 2014-04
- Volume
- 5
- Issue
- 2
- Pages
- 516-523
- ISSN
- 1949-3029 (ISSN-L)
- 1949-3037
- OpenAlex
- W1985039747
- Cited by
- 327
- References
- 6
- FWCI
- 19.73
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.