Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 185

The DOI matches its Crossref record.

Sequence-Based Control Strategy With Current Limiting for the Fault Ride-Through of Inverter-Interfaced Distributed Generators

Mahamedi, Behnam, Eskandari, Mohsen, Fletcher, John E., Zhu, Jianguo · 2020 · IEEE Transactions on Sustainable Energy

Abstract

Three-phase three-leg inverters represent the majority of inverters that are integrated into low voltage power grids. They can develop positiveand negative-sequence components during unbalanced conditions including asymmetrical faults, but not zero-sequence components. This indicates that a sequence-based control strategy is required for comprehensive control of inverter currents and voltages. Positiveand negative-sequence components must be controlled separately with their own dedicated controllers in such a scheme. Given this critical need, a sequence-based control technique for grid-forming and grid-feeding inverter-interfaced distributed generators is proposed. As a necessary part of the fault ride-through capability of inverter-interfaced distributed generators, a current limiter is developed, which can limit inverter currents at a pre-defined threshold for both balanced and unbalanced faults. Whilst the current regulators work in the synchronous reference frame with simple PI controllers, the limiter works in the natural reference frame and thus treats each phase current separately, which results in current limiting at the threshold for all phases. The advantage of the proposed limiter is that it acts instantaneously such that the inverter current can be limited from the start of the disturbance. The simulation results in MATLAB/SIMULINK reveal promising performance of the proposed control strategy with the proposed current limiting.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tste.2018.2887149

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 185

Metadata

Authors
Mahamedi, B., Eskandari, M., Fletcher, J. E., & Zhu, J.
Venue
IEEE Transactions on Sustainable Energy
Published
2020-01
Volume
11
Issue
1
Pages
165-174
ISSN
  • 1949-3029 (ISSN-L)
  • 1949-3037
OpenAlex
W2905126141
Cited by
185
References
0
FWCI
6.52
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Sequence-Based Control Strategy With Current Limiting for the Fault Ride-Through of Inverter-Interfaced Distributed Generators. https://app.cochat.ai/papers/10.1109/tste.2018.2887149
The paper
Mahamedi, B., Eskandari, M., Fletcher, J. E., & Zhu, J. (2020). Sequence-Based Control Strategy With Current Limiting for the Fault Ride-Through of Inverter-Interfaced Distributed Generators. IEEE Transactions on Sustainable Energy. https://doi.org/10.1109/tste.2018.2887149

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.