Generalized Virtual Synchronous Generator Control Design for Renewable Power Systems
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Grid-forming inverters (GFMIs) are recognized as one of the key enablers towards highly renewable energy proliferated grids. One of the pivotal characteristicsof GFMIs is the ability to seamlessly switch between grid-connected (GC) and standalone (SA) modes. In this paper, a novel controller is proposed to accurately follow the power reference commands in the GC mode while providing the required amount of virtual inertia in the SA mode to slow down the rate of change of frequency (RoCoF) following a disturbance. The proposed control design, where straightforward equations are given to calculate the controller gains directly, is based on the frequency response of the open-loop system. Furthermore, based on the frequency response of the controller, a condition for the placement of the poles of the controller is derived to guarantee the RoCoF relay limit compliance in the SA mode. The experimental results show that the proposed controller results in lower overshoots and shorter settling times in step responses in the GC mode than the virtual synchronous generator (VSG) controller while providing more virtual inertia than the VSG controller to slow down RoCoF in the SA mode. Furthermore, the experimental results illustrate that the proposed controller can also be designed to support the grid during frequency transients. The performance of the controller is extensively validated experimentally during GC to SA mode transition and vice versa, in a multi-inverter network, and in a wide-area model.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Frequency Stability of Synchronous Machines and Grid-Forming Power Converters
Tayyebi, A., Gross, D., Anta, A., Kupzog, F., & Dorfler, F. (2020) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2020.2966524 · Cited by 442
Cited by
Mohammed, N., Udawatte, H., Zhou, W., Hill, D. J., & Bahrani, B. (2024) · IEEE Open Journal of the Industrial Electronics Society · doi:10.1109/ojies.2024.3371985 · Cited by 183
Self-citationMohammed, N., Ravanji, M. H., Zhou, W., & Bahrani, B. (2023) · IEEE Transactions on Sustainable Energy · doi:10.1109/tste.2022.3223976 · Cited by 129
Self-citationRathnayake, D. B., & Bahrani, B. (2023) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2022.3213692 · Cited by 69
Self-citation
Metadata
- Authors
- Rathnayake, D. B., Razzaghi, R., & Bahrani, B.
- Venue
- IEEE Transactions on Sustainable Energy
- Published
- 2022-04
- Volume
- 13
- Issue
- 2
- Pages
- 1021-1036
- ISSN
- 1949-3029 (ISSN-L)
- 1949-3037
- OpenAlex
- W4205214004
- Cited by
- 167
- References
- 1
- FWCI
- 12.67
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.