CoChat

Early Intermittent Interturn Fault Detection and Localization for a Permanent Magnet Synchronous Motor of Electrical Vehicles Using Wavelet Transform

Open access
Haje Obeid, Najla, Battiston, Alexandre, Boileau, Thierry, Nahid-Mobarakeh, Babak · 2017 · IEEE Transactions on Transportation Electrification

The DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.

Abstract

In order to improve hybrid and electrical vehicles functional safety and to avoid sudden failures, it is important to develop reliable and robust on-board diagnostics (OBD). This paper discusses the stator incipient fault diagnosis and monitoring of a permanent magnet synchronous motor for hybrid and electrical vehicles. Incipient stator fault appears as intermittent interturn faults. Studying this phenomenon had shown that it generates specific distortions in the statoric currents as well as in the reference voltages. The fault monitoring method is based on the identification of these specific distortions and on the localization of the phase containing the defected turns. The theoretical and the experimental results show the effectiveness of the method.

Overview

Integrity signals

Registry

Crossref · 10.1109/tte.2017.2743419

Cites

24 of 24 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

The text we found for this paper looks like another document, so its claims and self-check weren’t run. The registry and citation checks still apply.

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The text we found for this paper looks like another document, so the self-check wasn’t run.

Citations

Cites

Show all 24 references

Research works printed but not linked: 2

  1. obeid, 2016, Modèle dynamique et signature du défaut inter-spire intermittent dans les têtes de bobines d’une MSAP, Proc Symp de Génie Electrique
  2. 2011, Road Vehicles—Functional Safety

Cited by

See all 99

Metadata

Authors
Haje Obeid, N., Battiston, A., Boileau, T., & Nahid-Mobarakeh, B.
Affiliations
  • IFP Énergies nouvelles (FR)
  • Groupe de Recherche en Énergie Électrique de Nancy (FR)
Venue
IEEE Transactions on Transportation Electrification
Published
2017-09
Volume
3
Issue
3
Pages
694-702
ISSN
2332-7782 (ISSN-L)
OpenAlex
W2747590226
Cited by
98
References
24
Citations by year
2026: 4 · 2025: 9 · 2024: 17 · 2023: 15 · 2022: 16 · 2021: 8 · 2020: 12 · 2019: 8 · 2018: 9
FWCI
4.98
Type
journal article
Language
en
Open access
Locations
  • IEEE Transactions on Transportation Electrification (publishedVersion)
  • HAL (submittedVersion, other-oa)
Topics
  • Physical Sciences › Engineering › Control and Systems Engineering › Machine Fault Diagnosis Techniques
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Electric Motor Design and Analysis
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Sensorless Control of Electric Motors
Keywords
permanent magnet synchronous motor, fault detection, fault location, wavelet transform, stator fault diagnosis, on-board diagnostics, hybrid electric vehicles, electric vehicles, functional safety

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Early Intermittent Interturn Fault Detection and Localization for a Permanent Magnet Synchronous Motor of Electrical Vehicles Using Wavelet Transform. https://app.cochat.ai/papers/10.1109/tte.2017.2743419
The paper
Haje Obeid, N., Battiston, A., Boileau, T., & Nahid-Mobarakeh, B. (2017). Early Intermittent Interturn Fault Detection and Localization for a Permanent Magnet Synchronous Motor of Electrical Vehicles Using Wavelet Transform. IEEE Transactions on Transportation Electrification. https://doi.org/10.1109/tte.2017.2743419

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.