Early Intermittent Interturn Fault Detection and Localization for a Permanent Magnet Synchronous Motor of Electrical Vehicles Using Wavelet Transform
Open accessThe DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
Abstract
In order to improve hybrid and electrical vehicles functional safety and to avoid sudden failures, it is important to develop reliable and robust on-board diagnostics (OBD). This paper discusses the stator incipient fault diagnosis and monitoring of a permanent magnet synchronous motor for hybrid and electrical vehicles. Incipient stator fault appears as intermittent interturn faults. Studying this phenomenon had shown that it generates specific distortions in the statoric currents as well as in the reference voltages. The fault monitoring method is based on the identification of these specific distortions and on the localization of the phase containing the defected turns. The theoretical and the experimental results show the effectiveness of the method.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The text we found for this paper looks like another document, so the self-check wasn’t run.
Citations
Cites
Grubic, S., Aller, J. M., Lu, B., & Habetler, T. G. (2008) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2008.2004665 · Cited by 490 · cited 1×
“Many studies have been developed in order to d e ect this type of fault [6].”
BackgroundWavelets and their Applications
(2007) · Wiley eBooks · doi:10.1002/9780470612491 · Cited by 468
Detection and location of interturn short circuits in the stator windings of operating motors
Penman, J., Sedding, H. G., Lloyd, B. A., & Fink, W. T. (1994) · IEEE Transactions on Energy Conversion · doi:10.1109/60.368345 · Cited by 394 · cited 1×
“The insulation breakdown between two turns in the stator winding consist a critical electrical machine fault [5].”
BackgroundFeng, G., Lai, C., Mukherjee, K., & Kar, N. C. (2016) · IEEE Transactions on Transportation Electrification · doi:10.1109/tte.2016.2538180 · Cited by 195 · cited 1×
“Permanent magnet synchronous motors (PMSM) are widely used in hybrid and electric vehicles because of their high-efficiency, their high-power density and their compact design [3,4].”
BackgroundA novel technique for selecting mother wavelet function using an intelli gent fault diagnosis system
Rafiee, J., Tse, P. W., Harifi, A., & Sadeghi, M. H. (2009) · Expert Systems with Applications · doi:10.1016/j.eswa.2008.05.052 · Cited by 188
Algorithms for designing wavelets to match a specified signal
Rao, R. M., & Chapa, J. O. (2000) · IEEE Transactions on Signal Processing · doi:10.1109/78.887001 · Cited by 159 · cited 1×
“The best basis to represe nt the fault signature is an adapted wavelet [21-26].”
BackgroundAubert, B., Regnier, J., Caux, S., & Alejo, D. (2015) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2014.2348934 · Cited by 137
Du, B., Wu, S., Han, S., & Cui, S. (2016) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2015.2496900 · Cited by 105 · cited 2×
“The developed identification method s are mostly based on frequency analysis [7-12].”
MethodFault Analysis and Parameter Identification of Permanent-Magnet Motors by the Finite-Element Method
Vaseghi, B., Takorabet, N., & Meibody-Tabar, F. (2009) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2009.2022156 · Cited by 104
Fault Diagnosis for Electric Drive Systems of Electrified Vehicles Based on Structural Analysis
Zhang, J., Yao, H., & Rizzoni, G. (2017) · IEEE Transactions on Vehicular Technology · doi:10.1109/tvt.2016.2556691 · Cited by 96 · cited 2×
“According to [2], an effective way to guarantee the hybrid or electrical vehicles functional safety is to develop on-board diagnostics (OBD) that are in compliance with the functional safety standards.”
Background
Research works printed but not linked: 2
- obeid, 2016, Modèle dynamique et signature du défaut inter-spire intermittent dans les têtes de bobines d’une MSAP, Proc Symp de Génie Electrique
- 2011, Road Vehicles—Functional Safety
Cited by
Fault Diagnosis and Fault-Tolerant Control of PMSM Drives–State of the Art and Future Challenges
Orlowska-Kowalska, T., Wolkiewicz, M., Pietrzak, P., Skowron, M., Ewert, P., Tarchala, G., Krzysztofiak, M., & Kowalski, C. T. (2022) · IEEE Access · doi:10.1109/access.2022.3180153 · Cited by 328
“The quadrature component of the reference voltage vector is used as the diagnostic signal in [69] and [73].”
BackgroundMethodInfluentialReview on Diagnosis Techniques for Intermittent Faults in Dynamic Systems
Zhou, D., Zhao, Y., Wang, Z., He, X., & Gao, M. (2020) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2019.2907500 · Cited by 241
“The corresponding IF localization problem has been further studied in [72] to identify the phase containing defective turns.”
BackgroundMethodFaults and Diagnosis Methods of Permanent Magnet Synchronous Motors: A Review
Chen, Y., Liang, S., Li, W., Liang, H., & Wang, C. (2019) · Applied Sciences · doi:10.3390/app9102116 · Cited by 194
“used the method based on WT to identify the short circuit winding phase in PMSM [71].”
MethodHang, J., Zhang, J., Xia, M., Ding, S., & Hua, W. (2020) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2019.2953269 · Cited by 150
“In [15], the fault incipient stator fault detection and localization for the PMSM is achieved based on the distortions in the stator currents as well as in the reference voltages and wavelet transform.”
MethodBelkhier, Y., Oubelaid, A., & Shaw, R. N. (2023) · Energy Storage · doi:10.1002/est2.511 · Cited by 95
“11,12 The development of the hybrid electric vehicle requires multiple skills due to its design and energy management which classifies it as a multidisciplinary sys-tem.”
Background
Metadata
- Authors
- Haje Obeid, N., Battiston, A., Boileau, T., & Nahid-Mobarakeh, B.
- Affiliations
- IFP Énergies nouvelles (FR)
- Groupe de Recherche en Énergie Électrique de Nancy (FR)
- Venue
- IEEE Transactions on Transportation Electrification
- Published
- 2017-09
- Volume
- 3
- Issue
- 3
- Pages
- 694-702
- ISSN
- 2332-7782 (ISSN-L)
- OpenAlex
- W2747590226
- Cited by
- 98
- References
- 24
- Citations by year
- 2026: 4 · 2025: 9 · 2024: 17 · 2023: 15 · 2022: 16 · 2021: 8 · 2020: 12 · 2019: 8 · 2018: 9
- FWCI
- 4.98
- Type
- journal article
- Language
- en
- Open access
- green
- ifp.hal.science
- Locations
- IEEE Transactions on Transportation Electrification (publishedVersion)
- HAL (submittedVersion, other-oa)
- Topics
- Physical Sciences › Engineering › Control and Systems Engineering › Machine Fault Diagnosis Techniques
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Electric Motor Design and Analysis
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Sensorless Control of Electric Motors
- Keywords
- permanent magnet synchronous motor, fault detection, fault location, wavelet transform, stator fault diagnosis, on-board diagnostics, hybrid electric vehicles, electric vehicles, functional safety
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Early Intermittent Interturn Fault Detection and Localization for a Permanent Magnet Synchronous Motor of Electrical Vehicles Using Wavelet Transform. https://app.cochat.ai/papers/10.1109/tte.2017.2743419
- The paper
- Haje Obeid, N., Battiston, A., Boileau, T., & Nahid-Mobarakeh, B. (2017). Early Intermittent Interturn Fault Detection and Localization for a Permanent Magnet Synchronous Motor of Electrical Vehicles Using Wavelet Transform. IEEE Transactions on Transportation Electrification. https://doi.org/10.1109/tte.2017.2743419
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.